- Content
-
... ... @@ -188,9 +188,9 @@ 188 188 * Allowable battery current to rejoin modules – a battery current at which joining of battery modules is permitted, A; 189 189 * Allowable voltage difference to rejoin modules – a difference between the voltage of the disconnected module and the battery voltage at which its joining is permitted, V; 190 190 * Checking voltages time – a time of checking voltages of battery modules before starting joining modules, millisecond; 191 -* Balancing modules time – a time of balancing battery modules after j, millisecond; 192 -* Control the precharging contactor – a flag to control the precharging contactor; 193 -* Canceling charging time – a delay before opening the charging contactor, ms; 191 +* Balancing modules time – a time of balancing battery modules after joining modules and before closing main charging contactor, millisecond; 192 +* Control the precharging contactor – a flag to control the main precharging contactor; 193 +* Canceling charging time – a delay before opening the main charging contactor, ms; 194 194 * Disconnect modules that are not ready to charge – a flag for disconnecting modules that have the “Ready to charge” signal cleared. 195 195 * Disconnect all modules if one is not ready to charge – a flag for disconnecting all modules if any of the modules have the “Ready to charge” signal cleared; 196 196 * Join modules on the “Charge request” signal – a flag to enable automatic modules joining if “Charge request” signal appears; ... ... @@ -249,7 +249,7 @@ 249 249 * Minimum number of modules allowed to join – a minimum number of battery modules that can be connected in parallel; 250 250 * Allowable battery current to rejoin modules – a battery current at which joining of battery modules is permitted, A; 251 251 * Allowable voltage difference to rejoin modules – a difference between the voltage of the disconnected module and the battery voltage at which its joining is permitted, V; 252 -* Checking voltages time – a time of checking voltages of battery modules, millisecond; 252 +* Checking voltages time – a time of checking voltages of battery modules before starting joining modules, millisecond; 253 253 * Balancing modules time – a time of balancing battery modules, millisecond; 254 254 * Control the precharging contactor – a flag to control the main precharging contactor; 255 255 * Canceling discharging time – a delay before opening the main discharging contactor, millisecond;