Changes for page 3.3 Control
Last modified by Admin on 2025/05/30 16:50
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -112,7 +112,7 @@ 112 112 113 113 In this section: 114 114 115 -[[image:1739290619354-792.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="1 17" width="600"]]115 +[[image:1739290619354-792.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="155" width="800"]] 116 116 117 117 * Precharge current threshold to close the discharging contactor – a current value to ensure that precharge process has finished and it is allowed to close the discharging contactor, A; 118 118 * Check voltages before and after contactors to finish precharging – a flag to check the voltages before and after contactors to ensure that precharge process has finished and it is allowed to close the discharging contactor; ... ... @@ -127,10 +127,10 @@ 127 127 * Delay before clearing the "Precharge error", second; 128 128 * Lock – a flag to block the error until the device is restarted. 129 129 130 -“Precharge error” generation conditions if any of the following is true:130 +“Precharge error” generation conditions: 131 131 132 -* the precharge current does not decrease during t he"Precharge time" after "Number of precharging attempts";133 -* voltages before and after contactors are not equal duringthe "Precharge time" after "Number of precharging attempts";132 +* the precharge current does not decrease during t after "Number of precharging attempts"; 133 +* voltages before and after contactors are not equal after "Number of precharging attempts"; 134 134 * power dissipated on the precharge resistor is above the maximum value during the “Delay before setting the 'Precharge error' when checking power” time. 135 135 136 136 (% class="box warningmessage" %) ... ... @@ -187,10 +187,10 @@ 187 187 * Minimum number of modules allowed to join – a minimum number of battery modules that can be connected in parallel; 188 188 * Allowable battery current to rejoin modules – a battery current at which joining of battery modules is permitted, A; 189 189 * Allowable voltage difference to rejoin modules – a difference between the voltage of the disconnected module and the battery voltage at which its joining is permitted, V; 190 -* Checking voltages time – a time of checking voltages of battery modules before starting joining modules, millisecond;191 -* Balancing modules time – a time of balancing battery modules b, millisecond;192 -* Control the precharging contactor – a flag to control the precharging contactor; 193 -* Canceling charging time – a delay before opening the charging contactor, ms; 190 +* Checking voltages time – a time of checking voltages of battery modules, millisecond; 191 +* Balancing modules time – a time of balancing battery modules, millisecond; 192 +* Control the precharging contactor – a flag to control the main precharging contactor; 193 +* Canceling charging time – a delay before opening the main charging contactor, ms; 194 194 * Disconnect modules that are not ready to charge – a flag for disconnecting modules that have the “Ready to charge” signal cleared. 195 195 * Disconnect all modules if one is not ready to charge – a flag for disconnecting all modules if any of the modules have the “Ready to charge” signal cleared; 196 196 * Join modules on the “Charge request” signal – a flag to enable automatic modules joining if “Charge request” signal appears;