Changes for page 3.3 Control
Last modified by Admin on 2025/05/30 16:50
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -112,7 +112,7 @@ 112 112 113 113 In this section: 114 114 115 -[[image:1739290619354-792.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="1 55" width="800"]]115 +[[image:1739290619354-792.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="117" width="600"]] 116 116 117 117 * Precharge current threshold to close the discharging contactor – a current value to ensure that precharge process has finished and it is allowed to close the discharging contactor, A; 118 118 * Check voltages before and after contactors to finish precharging – a flag to check the voltages before and after contactors to ensure that precharge process has finished and it is allowed to close the discharging contactor; ... ... @@ -187,10 +187,10 @@ 187 187 * Minimum number of modules allowed to join – a minimum number of battery modules that can be connected in parallel; 188 188 * Allowable battery current to rejoin modules – a battery current at which joining of battery modules is permitted, A; 189 189 * Allowable voltage difference to rejoin modules – a difference between the voltage of the disconnected module and the battery voltage at which its joining is permitted, V; 190 -* Checking voltages time – a time of checking voltages of battery modules, millisecond; 191 -* Balancing modules time – a time of balancing battery modules, millisecond; 192 -* Control the precharging contactor – a flag to control the mainprecharging contactor;193 -* Canceling charging time – a delay before opening the maincharging contactor, ms;190 +* Checking voltages time – a time of checking voltages of battery modules before starting joining modules, millisecond; 191 +* Balancing modules time – a time of balancing battery modules b, millisecond; 192 +* Control the precharging contactor – a flag to control the precharging contactor; 193 +* Canceling charging time – a delay before opening the charging contactor, ms; 194 194 * Disconnect modules that are not ready to charge – a flag for disconnecting modules that have the “Ready to charge” signal cleared. 195 195 * Disconnect all modules if one is not ready to charge – a flag for disconnecting all modules if any of the modules have the “Ready to charge” signal cleared; 196 196 * Join modules on the “Charge request” signal – a flag to enable automatic modules joining if “Charge request” signal appears;