Changes for page 3.3 Control
Last modified by Admin on 2025/05/30 16:50
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -299,7 +299,7 @@ 299 299 300 300 The charge/discharge contactor control is configured in the “Control → Charge/Discharge” section: 301 301 302 -[[image:173 4089702994-738.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="92" width="600"]]302 +[[image:1739292809635-913.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="238" width="800"]] 303 303 304 304 In this section: 305 305 ... ... @@ -315,16 +315,17 @@ 315 315 * Balancing modules time – a time of balancing battery modules after joining modules and before closing main discharging contactor, millisecond; 316 316 * Control the precharging contactor – a flag to control the main precharging contactor; 317 317 * Canceling discharging time – a delay before opening the main discharging contactor, millisecond; 318 -* Disconnect modules that are not ready to charge – a flag for disconnecting modules that have the “Ready to charge” signal cleared. 319 -* Disconnect modules that are not ready to discharge – a flag for disconnecting modules that have the “Ready to discharge” signal cleared. 320 -* Disconnect all modules if one is not ready to discharge – a flag for disconnecting all modules if one of the modules have the “Ready to discharge” signal cleared; 321 -* Disconnect all modules if one is not ready to discharge – a flag for disconnecting all modules if one of the modules have the “Ready to discharge” signal cleared; 318 +* Disconnect modules that are not ready to charge – a flag for disconnecting modules that have the “Ready to charge” signal cleared; 319 +* Disconnect modules that are not ready to discharge – a flag for disconnecting modules that have the “Ready to discharge” signal cleared; 320 +* Join modules on the “Charge request” signal – a flag to enable automatic modules joining if “Charge request” signal appears; 322 322 * Join modules on the “Discharge request” signal – a flag to enable automatic modules joining if “Discharge request” signal appears; 322 +* Maximum CONTINUOUS charge current limit – a maximum allowed continuous charging current of all the battery, A; 323 +* Maximum charge current limit – a maximum allowed charging current of all the battery, A; 323 323 * Maximum CONTINUOUS discharge current limit – a maximum allowed continuous discharging current of all the battery, A; 324 324 * Maximum discharge current limit – a maximum allowed discharging current of all the battery, A; 325 325 * Errors 1 (2) to disconnect all battery modules – errors that cause all battery modules to be disconnected from the common bus; 326 -* Errors 1 (2) to open the discharging contactor – errors that cause the main discharging contactor "Discharging" to open, 327 -* Switch of the discharging contactor on errors without a delay – a flag that allows the main discharging contactor “Discharging”to be opened without delay if errors are detected.327 +* Errors 1 (2) to open the charging/discharging contactor – errors that cause the main charging/discharging contactor "Discharging" to open, 328 +* Switch of the charging/discharging contactor on errors without a delay – a flag that allows the main charging/discharging contactor to be opened without delay if errors are detected. 328 328 329 329 === Module balancing === 330 330
- 1739292809635-913.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +60.7 KB - Content