Changes for page 3.3 Control
Last modified by Admin on 2025/05/30 16:50
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -41,7 +41,7 @@ 41 41 * Minimal SOC – SOC of the modular battery is assumed to be the minimum SOC among the battery modules; 42 42 * Average SOC – SOC of the modular battery is taken equal to the arithmetic average of the SOC of the battery modules; 43 43 * Min-Max SOC – the battery SOC is calculated based on the minimum and maximum SOC of the modules. Final SOC will be a) 100% if any module has 100% SOC, b) 0% if any module has 0% SOC; 44 -* Max-Min SOC – the battery SOC is calculated based on the minimum and maximum SOC of the modules. Final SOC will be a) 100% if all modules have 100% SOC, b) 0% if all modules have 0% SOC;44 +* Max-Min SOC – the battery SOC is calculated based on the minimum and maximum SOC of the cells. Final SOC will be a) 100% if all modules have 100% SOC, b) 0% if all modules have 0% SOC; 45 45 46 46 Calculation of the battery state of health (SOH) is configured in the "Control → Calculation → Final SOH" section. The following battery SOH calculation methods are supported: 47 47 ... ... @@ -110,9 +110,8 @@ 110 110 111 111 To change the precharge parameters, select the section “Control → Precharge”: 112 112 113 -In this section: 113 +[[image:1738080762857-975.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="108" width="600"]]In this section: 114 114 115 -[[image:1739290619354-792.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="155" width="800"]] 116 116 117 117 * Precharge current threshold to close the discharging contactor – a current value to ensure that precharge process has finished and it is allowed to close the discharging contactor, A; 118 118 * Check voltages before and after contactors to finish precharging – a flag to check the voltages before and after contactors to ensure that precharge process has finished and it is allowed to close the discharging contactor; ... ... @@ -125,11 +125,11 @@ 125 125 * Maximum allowable power dissipated in the resistor, W; 126 126 * Delay before setting the "Precharge error" when checking power, millisecond; 127 127 * Delay before clearing the "Precharge error", second; 128 -* Lock – a flag to block the error until the device is restarted. 127 +* Lock the "Precharge error" – a flag to block the error until the device is restarted. 129 129 130 130 “Precharge error” generation conditions: 131 131 132 -* the precharge current does not decrease durafter "Number of precharging attempts";131 +* the precharge current does not decrease after "Number of precharging attempts"; 133 133 * voltages before and after contactors are not equal after "Number of precharging attempts"; 134 134 * power dissipated on the precharge resistor is above the maximum value during the “Delay before setting the 'Precharge error' when checking power” time. 135 135
- 1739290619354-792.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -41.2 KB - Content