... ... @@ -282,19 +282,21 @@
282 282  
283 283  The operation of the **joining battery modules** depends on the signal received:
284 284  
285 -* If "Join to charge" is received, joining procedure is
285 +* If "Join to charge" is received, joining procedure is done as described in [[Charge>>doc:||anchor="HCharge"]] section;
286 +* If "Join to discharge" is received, joining procedure is done as described in [[Discharge>>doc:||anchor="HDischarge"]] section;
287 +* If both signals received, "Join to charge" has a priority.
286 286  
287 -The operation of **closing main discharging contactor** is described in the following steps:
289 +The operation of **closing main charging/discharging contactor **depends on the signal received:
288 288  
289 -1. The main discharging contactor “Discharging” is open. When the “Discharge request” is received, the voltage and current unbalance errors (“Voltage unbalance (DCH)”, “Current unbalance (DCH)”, “Discharging current unbalance”) are cleared, and the battery modules are joined, go to step 2.
290 -1. Closing the main precharging contactor (optional). Go to step 3.
291 -1. Closing the main discharging contactor "Discharging". Go to step 4.
292 -1. The main discharging contactor “Discharging” is closed. If the "Discharge request" is cleared, the battery modules are disconnected, or errors occur, go to step 1.
291 +* If "Charge request" is received, procedure is done as described in [[Charge>>doc:||anchor="HCharge"]] section;
292 +* If "Discharge request" is received, procedure is done as described in [[Discharge>>doc:||anchor="HDischarge"]] section;
293 +* If both signals received, "Charge request" has a priority.
293 293  
295 +
294 294  The command to turn on the main charging contactor "Discharging" can be issued either to the upper-level system via the CAN1 (ext) bus, or to the intelligent switch of the device, which serves for direct control of the main discharging contactor "Discharging".
295 295  
296 296  
297 -In addition to controlling the discharge contactors, the discharge controller calculates and transmits to the upper-level system the maximum allowable current value with which the modular battery can be discharged ("Discharge current limit"), as well as the maximum regeneration current value with which the modular battery can be charged during operation under load ("Regeneration current limit"). The calculation of the discharge current and regeneration current of the entire battery is performed based on the number of battery modules operating for discharge and the maximum discharge and charge current values ​​transmitted by them.
299 +In addition to controlling the charge/discharge contactor, the chargedischarge controller calculates and transmits to the upper-level system the maximum allowable current value with which the modular battery can be discharged ("Discharge current limit"), as well as the maximum regeneration current value with which the modular battery can be charged during operation under load ("Regeneration current limit"). The calculation of the discharge current and regeneration current of the entire battery is performed based on the number of battery modules operating for discharge and the maximum discharge and charge current values ​​transmitted by them.
298 298  
299 299  
300 300  The charge/discharge contactor control is configured in the “Control → Charge/Discharge” section: