Changes for page 3.3 Control
Last modified by Admin on 2025/05/30 16:50
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -266,6 +266,11 @@ 266 266 267 267 The BMS Main 3X can control the charging/discharging contactor that is used to both charge and discharge the battery. 268 268 269 +Charge/Discharge contactor has two algorithms of operation: 270 + 271 +* Dependent - Charge/Discharge contactor depends on Charge and Discharge algorithms and their signals and behaves as Charging contactor if Charging signal is set, otherwise – as Discharging contactor; 272 +* Independent - Charge/Discharge contactor is based on its own controller. 273 + 269 269 The charge/discharge contactor (“Charging/Discharging” signal) receives a “Charging” signal (generated by the charge controller) if a “Charge request” signal is received from the upper-level system. In all other cases, the "Discharging" signal is output to the contactor (generated by the discharge controller). 270 270 271 271 The charge/discharge contactor control is configured in the “Control → Charge/Discharge” section: