... ... @@ -41,7 +41,7 @@ 41 41 * Minimal SOC – SOC of the modular battery is assumed to be the minimum SOC among the battery modules; 42 42 * Average SOC – SOC of the modular battery is taken equal to the arithmetic average of the SOC of the battery modules; 43 43 * Min-Max SOC – the battery SOC is calculated based on the minimum and maximum SOC of the modules. Final SOC will be a) 100% if any module has 100% SOC, b) 0% if any module has 0% SOC; 44 -* Max-Min SOC – the battery SOC is calculated based on the minimum and maximum SOC of the cells. Final SOC will be a) 100% if all modules have 100% SOC, b) 0% if all modules have 0% SOC;44 +* Max-Min SOC – the battery SOC is calculated based on the minimum and maximum SOC of the modules. Final SOC will be a) 100% if all modules have 100% SOC, b) 0% if all modules have 0% SOC; 45 45 46 46 Calculation of the battery state of health (SOH) is configured in the "Control → Calculation → Final SOH" section. The following battery SOH calculation methods are supported: 47 47