Changes for page 3.3 Control
Last modified by Admin on 2025/05/30 16:50
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -40,8 +40,8 @@ 40 40 41 41 * Minimal SOC – SOC of the modular battery is assumed to be the minimum SOC among the battery modules; 42 42 * Average SOC – SOC of the modular battery is taken equal to the arithmetic average of the SOC of the battery modules; 43 -* Min-Max SOC – the battery SOCis calculated based on the minimumand maximum SOC of the modules.Final SOC will bea) 100% ifany modulehas 100% SOC, b) 0%if anymodulehas 0% SOC;44 -* Max-Min SOC – the battery SOCis calculated based on the minimumand maximum SOC of thecells. Final SOC willbea) 100% if allmoduleshave100% SOC, b) 0% if allmoduleshave0% SOC;43 +* Min-Max SOC – SOC of the modular battery is calculated based on the minimal and maximum SOC of the battery modules (optimized for maximum health); 44 +* Max-Min SOC – SOC of the modular battery is calculated based on the minimal and maximum SOC of the battery modules (optimized for maximum capacity, recommended); 45 45 46 46 Calculation of the battery state of health (SOH) is configured in the "Control → Calculation → Final SOH" section. The following battery SOH calculation methods are supported: 47 47