... ... @@ -26,7 +26,7 @@
26 26  
27 27  Each module in a battery must have a unique address. You can change the address in the battery module settings in the “Connectivity → CAN” section of the BMS Main 3 settings.
28 28  
29 -You can set up maximum number of found modules to finish initialization in corresponding section.
29 +In corresponding section you can set up maximum number of found modules to finish initialization.
30 30  
31 31  === Calculation of battery parameters ===
32 32  
... ... @@ -40,8 +40,8 @@
40 40  
41 41  * Minimal SOC – SOC of the modular battery is assumed to be the minimum SOC among the battery modules;
42 42  * Average SOC – SOC of the modular battery is taken equal to the arithmetic average of the SOC of the battery modules;
43 -* Min-Max SOC – SOC of the modular battery is calculated based on the minimal and maximum SOC of the battery modules (optimized for maximum health);
44 -* Max-Min SOC – SOC of the modular battery is calculated based on the minimal and maximum SOC of the battery modules (optimized for maximum capacity, recommended);
43 +* Min-Max SOC – the battery SOC is calculated based on the minimum and maximum SOC of the modules. Final SOC will be a) 100% if any module has 100% SOC, b) 0% if any module has 0% SOC;
44 +* Max-Min SOC – the battery SOC is calculated based on the minimum and maximum SOC of the modules. Final SOC will be a) 100% if all modules have 100% SOC, b) 0% if all modules have 0% SOC;
45 45  
46 46  Calculation of the battery state of health (SOH) is configured in the "Control → Calculation → Final SOH" section. The following battery SOH calculation methods are supported:
47 47  
... ... @@ -110,8 +110,9 @@
110 110  
111 111  To change the precharge parameters, select the section “Control → Precharge”:
112 112  
113 -[[image:1738080762857-975.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="108" width="600"]]In this section:
113 +In this section:
114 114  
115 +[[image:1739290619354-792.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="117" width="600"]]
115 115  
116 116  * Precharge current threshold to close the discharging contactor – a current value to ensure that precharge process has finished and it is allowed to close the discharging contactor, A;
117 117  * Check voltages before and after contactors to finish precharging – a flag to check the voltages before and after contactors to ensure that precharge process has finished and it is allowed to close the discharging contactor;
... ... @@ -124,12 +124,12 @@
124 124  * Maximum allowable power dissipated in the resistor, W;
125 125  * Delay before setting the "Precharge error" when checking power, millisecond;
126 126  * Delay before clearing the "Precharge error", second;
127 -* Lock the "Precharge error" – a flag to block the error until the device is restarted.
128 +* Lock – a flag to block the error until the device is restarted.
128 128  
129 -“Precharge error” generation conditions:
130 +“Precharge error” generation conditions if any of the following is true:
130 130  
131 -* the precharge current does not decrease after "Number of precharging attempts";
132 -* voltages before and after contactors are not equal after "Number of precharging attempts";
132 +* the precharge current does not decrease during the "Precharge time" after "Number of precharging attempts";
133 +* voltages before and after contactors are not equal during the "Precharge time" after "Number of precharging attempts";
133 133  * power dissipated on the precharge resistor is above the maximum value during the “Delay before setting the 'Precharge error' when checking power” time.
134 134  
135 135  (% class="box warningmessage" %)
... ... @@ -186,8 +186,8 @@
186 186  * Minimum number of modules allowed to join – a minimum number of battery modules that can be connected in parallel;
187 187  * Allowable battery current to rejoin modules – a battery current at which joining of battery modules is permitted, A;
188 188  * Allowable voltage difference to rejoin modules – a difference between the voltage of the disconnected module and the battery voltage at which its joining is permitted, V;
189 -* Checking voltages time – a time of checking voltages of battery modules, millisecond;
190 -* Balancing modules time – a time of balancing battery modules, millisecond;
190 +* Checking voltages time – a time of checking voltages of battery modules before starting joining modules, millisecond;
191 +* Balancing modules time – a time of balancing battery modules after joining modules and before closing main charging contactor, millisecond;
191 191  * Control the precharging contactor – a flag to control the main precharging contactor;
192 192  * Canceling charging time – a delay before opening the main charging contactor, ms;
193 193  * Disconnect modules that are not ready to charge – a flag for disconnecting modules that have the “Ready to charge” signal cleared.
... ... @@ -236,7 +236,7 @@
236 236  
237 237  The battery discharge management is configured in the "Control → Discharge" section:
238 238  
239 -[[image:1734089702987-534.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="179" width="600"]]
240 +[[image:1738081173083-894.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="162" width="600"]]
240 240  
241 241  In this section:
242 242  
... ... @@ -248,17 +248,14 @@
248 248  * Minimum number of modules allowed to join – a minimum number of battery modules that can be connected in parallel;
249 249  * Allowable battery current to rejoin modules – a battery current at which joining of battery modules is permitted, A;
250 250  * Allowable voltage difference to rejoin modules – a difference between the voltage of the disconnected module and the battery voltage at which its joining is permitted, V;
251 -* Checking voltages time – a time of checking voltages of battery modules, millisecond;
252 -* Pre-balancing modules time – a time of precharging battery modules, millisecond;
253 -* Balancing modules time – a time of balancing battery modules, millisecond;
252 +* Checking voltages time – a time of checking voltages of battery modules before starting joining modules, millisecond;
253 +* Balancing modules time – a time of balancing battery modules after joining modules and before closing main discharging contactor, millisecond;
254 254  * Control the precharging contactor – a flag to control the main precharging contactor;
255 -* Precharging time – a time of precharging, millisecond;
256 256  * Canceling discharging time – a delay before opening the main discharging contactor, millisecond;
257 -* Limit module current – a flag that allows to limit the discharging current of a modular battery so that the current of each battery module does not exceed its maximum allowable discharge current;
258 -* Slew rate – a rate of change of the discharge current limit when the “Limit module current” flag is set, A/s;
259 259  * Disconnect modules that are not ready to discharge – a flag for disconnecting modules that have the “Ready to discharge” signal cleared.
260 260  * Disconnect all modules if one is not ready to discharge – a flag for disconnecting all modules if one of the modules have the “Ready to discharge” signal cleared;
261 261  * Join modules on the “Discharge request” signal – a flag to enable automatic modules joining if “Discharge request” signal appears;
259 +* Maximum CONTINUOUS discharge current limit – a maximum allowed continuous discharging current of all the battery, A;
262 262  * Maximum discharge current limit – a maximum allowed discharging current of all the battery, A;
263 263  * Errors 1 (2) to disconnect all battery modules – errors that cause all battery modules to be disconnected from the common bus;
264 264  * Errors 1 (2) to open the discharging contactor – errors that cause the main discharging contactor "Discharging" to open,
... ... @@ -268,15 +268,66 @@
268 268  
269 269  The BMS Main 3X can control the charging/discharging contactor that is used to both charge and discharge the battery.
270 270  
271 -The charge/discharge contactor (“Charging/Discharging” signal) receives a “Charging” signal (generated by the charge controller) if a “Charge request” signal is received from the upper-level system. In all other cases, the "Discharging" signal is output to the contactor (generated by the discharge controller).
269 +Charge/Discharge contactor has two algorithms of operation:
272 272  
271 +* Dependent - Charge/Discharge contactor depends on Charge and Discharge algorithms and their signals and behaves as Charging contactor if "Charging" signal is set, otherwise – as Discharging contactor;
272 +* Independent - Charge/Discharge contactor is based on its own controller.
273 +
274 +The charging/discharging controller supports the following modes:
275 +
276 +1. Charging/Discharging is always allowed (Always on) – the device ignores voltage and current unbalance of the battery modules and commands to close the discharging contactors of the battery modules and the main discharging contactor.
277 +1. Charging/Discharging is allowed if all battery modules are balanced (Balanced).
278 +1. Charging/Discharging is allowed for most balanced battery modules (Partially balanced). Unbalanced modules are disconnected from the common bus and do not participate in the discharging.
279 +
280 +The device controls two processes: **joining battery modules** and **closing the main charging/discharging contactor**.
281 +
282 +The operation of the **joining battery modules** depends on the signal received:
283 +
284 +* If "Join to charge" is received, joining procedure is done as described in [[Charge>>doc:||anchor="HCharge"]] section;
285 +* If "Join to discharge" is received, joining procedure is done as described in [[Discharge>>doc:||anchor="HDischarge"]] section;
286 +* If both signals received, "Join to charge" has a priority.
287 +
288 +The operation of **closing main charging/discharging contactor **depends on the signal received:
289 +
290 +* If "Charge request" is received, procedure is done as described in [[Charge>>doc:||anchor="HCharge"]] section;
291 +* If "Discharge request" is received, procedure is done as described in [[Discharge>>doc:||anchor="HDischarge"]] section;
292 +* If both signals received, "Charge request" has a priority.
293 +
294 +
295 +In addition, the charge/discharge controller calculates and transmits to the upper-level system the maximum allowable current value with which the modular battery can be charged ("Charge current limit") and discharged ("Discharge current limit"), as well as the maximum regeneration current value with which the modular battery can be charged during operation under load ("Regeneration current limit"). The calculation of the charge, discharge and regeneration currents of the entire battery is performed based on the number of battery modules operating for charge or discharge and the maximum charge and discharge current values ​​transmitted by them:
296 +
297 +* "Charge current limit" and "Regeneration current limit" are calculated only if there is "Charge request";
298 +* "Discharge current limit" is calculated only if there is "Discharge request".
299 +
273 273  The charge/discharge contactor control is configured in the “Control → Charge/Discharge” section:
274 274  
275 -[[image:1734089702994-738.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="92" width="600"]]
302 +[[image:1739292809635-913.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="238" width="800"]]
276 276  
277 277  In this section:
278 278  
279 -* Enable – a flag to enable the charge/discharge controller.
306 +* Enable – a flag to enable battery charge/discharge controller;
307 +* Algorithm:
308 +** Always on – discharging is always allowed;
309 +** Balanced – discharging is allowed provided that all battery modules are balanced;
310 +** Partially balanced – discharging is allowed for most balanced battery modules;
311 +* Minimum number of modules allowed to join – a minimum number of battery modules that can be connected in parallel;
312 +* Allowable battery current to rejoin modules – a battery current at which joining of battery modules is permitted, A;
313 +* Allowable voltage difference to rejoin modules – a difference between the voltage of the disconnected module and the battery voltage at which its joining is permitted, V;
314 +* Checking voltages time – a time of checking voltages of battery modules before starting joining modules, millisecond;
315 +* Balancing modules time – a time of balancing battery modules after joining modules and before closing main discharging contactor, millisecond;
316 +* Control the precharging contactor – a flag to control the main precharging contactor;
317 +* Canceling discharging time – a delay before opening the main discharging contactor, millisecond;
318 +* Disconnect modules that are not ready to charge – a flag for disconnecting modules that have the “Ready to charge” signal cleared;
319 +* Disconnect modules that are not ready to discharge – a flag for disconnecting modules that have the “Ready to discharge” signal cleared;
320 +* Join modules on the “Charge request” signal – a flag to enable automatic modules joining if “Charge request” signal appears;
321 +* Join modules on the “Discharge request” signal – a flag to enable automatic modules joining if “Discharge request” signal appears;
322 +* Maximum CONTINUOUS charge current limit – a maximum allowed continuous charging current of all the battery, A;
323 +* Maximum charge current limit – a maximum allowed charging current of all the battery, A;
324 +* Maximum CONTINUOUS discharge current limit – a maximum allowed continuous discharging current of all the battery, A;
325 +* Maximum discharge current limit – a maximum allowed discharging current of all the battery, A;
326 +* Errors 1 (2) to disconnect all battery modules – errors that cause all battery modules to be disconnected from the common bus;
327 +* Errors 1 (2) to open the charging/discharging contactor – errors that cause the main charging/discharging contactor "Discharging" to open,
328 +* Switch of the charging/discharging contactor on errors without a delay – a flag that allows the main charging/discharging contactor to be opened without delay if errors are detected.
280 280  
281 281  === Module balancing ===
282 282  