Changes for page 6. Firmware update

Last modified by Admin on 2026/04/02 09:14

From version 6.2
edited by Admin
on 2024/12/26 17:11
Change comment: There is no comment for this version
To version 14.1
edited by Admin
on 2026/04/02 09:14
Change comment: There is no comment for this version

Summary

Details

Page properties
Title
... ... @@ -1,1 +1,1 @@
1 -5. Firmware update
1 +6. Firmware update
Content
... ... @@ -1,21 +1,23 @@
1 -(% data-numbered-headings-start="5" style="--numbered-headings-start: 4;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
1 +(% data-numbered-headings-start="6" style="--numbered-headings-start: 5;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
2 2  = Firmware update =
3 3  
4 4  == Introduction ==
5 5  
6 -This document describes the steps for updating the BMS Main 3 / BMS Main 3X firmware.
6 +This document describes the steps for updating the BMS Main 3 / BMS Main 2R / BMS Main 3X firmware.
7 7  
8 -Updating the BMS Main 3 / BMS Main 3X firmware can be done in the following ways:
8 +Updating the BMS Main 3 / BMS Main 2R / BMS Main 3X firmware can be done in the following ways:
9 9  
10 -* via unified bootloader (available via USB only)
10 +* via bootloader (available via USB only);
11 11  * via device configuration interface (available via USB, CAN and TCP).
12 12  
13 13  The following hardware and software are required:
14 14  
15 -* ElectricDeviceMonitor application for Windows OS which is used for configuring the BMS Main 3 / BMS Main 3X;
16 -* USB/CAN adapter for updating via CAN bus;
17 -* USB cable for updating via Serial port;
18 -* BMS Wi-Fi or BMS LANmodule installed if updating via TCP;
15 +* ElectricDeviceMonitor application for Windows OS which is used for configuring the BMS Main 3 / BMS Main 2R / BMS Main 3X;
16 +* Communication device:
17 +** USB/CAN adapter — for updating via CAN bus;
18 +** USB-mini cable — for updating via USB;
19 +** BMS Wi-Fi or BMS LANmodule installed on BMS Main 3 — for update via TCP;
20 +* SD card — for updating via configuration interface;
19 19  * Firmware file (must be in .bin format).
20 20  
21 21  == Updating via bootloader ==
... ... @@ -27,7 +27,7 @@
27 27  
28 28  **~1. Start the device bootloader.**
29 29  
30 -* **Method 1**: using the Unified monitor of the ElectricDeviceMonitor program, connect to the BMS Main 3 / BMS Main 3X device via the USB, CAN or TCP connection. Next, in the monitor program, click the "Device → Go to bootloader" menu item:
32 +* **Method 1**: using the Unified monitor of the ElectricDeviceMonitor program, connect to the BMS Main 3 / BMS Main 2R / BMS Main 3X device via the USB, CAN or TCP connection. Next, in the monitor program, click the "Device → Go to bootloader" menu item:
31 31  
32 32  [[image:1733921869101-125.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]]
33 33  
... ... @@ -42,13 +42,12 @@
42 42  
43 43  **2. Upload the firmware.**
44 44  
45 -2.1 Launch the ElectricDeviceMonitor’s Updater module:
47 +2.1 Launch the ElectricDeviceMonitor’s Unified bootloader module:
46 46  
47 47  [[image:1735232992154-566.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="340" width="450"]]
48 48  
49 -[[image:1735233018575-198.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="316" width="300"]]2.2 From the drop-down menu of the Updater window, select the method of connecting to the BMS Main 3 / BMS Main 3X and configure the connection parameters (the "Settings..." button).
51 +[[image:1735233018575-198.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="316" width="300"]]2.2 From the drop-down menu of the Unified bootloader window, select the method of connecting to the BMS Main 3 / BMS Main 2R / BMS Main 3X and configure the connection parameters (the "Settings..." button).
50 50  
51 -
52 52  * **USB connection**: select the connection method “Serial port transport”, click the “Settings...” button. In the window that appears, select the COM port through which the PC connects to the device (the baud rate can be set to any):
53 53  
54 54  [[image:1733406142376-880.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]]
... ... @@ -57,7 +57,7 @@
57 57  
58 58  2.4 Click the “Update” button **while the device is in bootloader mode**. The process of loading the new firmware into the device memory will begin.
59 59  
60 -== Update via configuration interface ==
61 +== Update via Unified monitor ==
61 61  
62 62  (% class="box warningmessage" %)
63 63  (((