Changes for page 6.2 Modbus protocol
Last modified by Admin on 2025/03/20 12:12
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -225,11 +225,7 @@ 225 225 226 226 bit 25 — signal “Power up”; 227 227 228 -bit 26 — signal “External 1”; 229 - 230 -bit 27 — signal “Heater (AUX)”; 231 - 232 -bits 28-31 — not used. 228 +bits 26-31 — not used. 233 233 )))|(% style="width:37px" %)U32 234 234 |(% style="width:73px" %)**0x200B**|(% style="width:66px" %)1|(% style="width:437px" %)((( 235 235 Discrete output signals (bitfield): ... ... @@ -261,7 +261,7 @@ 261 261 262 262 bits 6-15 — not used. 263 263 )))|(% style="width:37px" %)U16 264 -|(% style="width:73px" %)**0x200E -0x200F**|(% style="width:66px" %)2|(% style="width:437px" %)(((260 +|(% style="width:73px" %)**0x200E**|(% style="width:66px" %)2|(% style="width:437px" %)((( 265 265 Errors 2 (bitfield): 266 266 267 267 bit 0 — error "Low temperature (CH)"; ... ... @@ -302,9 +302,7 @@ 302 302 303 303 bit 18 — “Power fault”; 304 304 305 -bit 19 — “Current limit" error; 306 - 307 -bits 20-31 — not used. 301 +bits 19-31 — not used. 308 308 )))|(% style="width:37px" %)U32 309 309 |(% style="width:73px" %)**0x2010**|(% style="width:66px" %)1|(% style="width:437px" %)Address of the BMS Logic device the parameters of which are in registers 0x2011-0x20C9|(% style="width:37px" %)U16 310 310 |(% style="width:73px" %)**0x2011**|(% style="width:66px" %)1|(% style="width:437px" %)((( ... ... @@ -390,9 +390,7 @@ 390 390 391 391 bit 4 — signal "Close Main contactor"; 392 392 393 -bit 5 — signal "Close External 1"; 394 - 395 -bits 6-15 — not used. 387 +bits 5-15 — not used. 396 396 )))|(% style="width:37px" %)U16 397 397 |(% style="width:73px" %)**0x2100-0x2101**|(% style="width:66px" %)2|(% style="width:437px" %)Battery state of charge (SOC), %|(% style="width:37px" %)REAL32 398 398 |(% style="width:73px" %)**0x2102**|(% style="width:66px" %)1|(% style="width:437px" %)Number of connected BMS Logic devices|(% style="width:37px" %)U16 ... ... @@ -434,10 +434,8 @@ 434 434 |(% style="width:73px" %)**0x217D-0x217E**|(% style="width:66px" %)2|(% style="width:437px" %)Coulomb consumed by the load, A×h|(% style="width:37px" %)REAL32 435 435 |(% style="width:73px" %)**0x21B8**|(% style="width:66px" %)1|(% style="width:437px" %)Flag indicating that some cell is being balanced|(% style="width:37px" %)U16 436 436 |(% style="width:73px" %)**0x21CA-0x21CB**|(% style="width:66px" %)2|(% style="width:437px" %)Average cell voltage, V|(% style="width:37px" %)REAL32 437 -|(% style="width:73px" %)**0x2400-0x2401**|(% style="width:66px" %)2|(% style="width:437px" %)Current (sensor 1, low range), A|(% style="width:37px" %)REAL32 438 -|(% style="width:73px" %)((( 439 -**0x2402-0x2403** 440 -)))|(% style="width:66px" %)2|(% style="width:437px" %)Final battery current, A|(% style="width:37px" %)REAL32 429 +|(% style="width:73px" %)**0x2400**|(% style="width:66px" %)2|(% style="width:437px" %)Current (sensor 1, low range), A|(% style="width:37px" %)REAL32 430 +|(% style="width:73px" %)**0x2402**|(% style="width:66px" %)2|(% style="width:437px" %)Final battery current, A|(% style="width:37px" %)REAL32 441 441 |(% style="width:73px" %)**0x2410**|(% style="width:66px" %)1|(% style="width:437px" %)((( 442 442 Battery state (enumeration): 443 443 ... ... @@ -455,7 +455,7 @@ 455 455 456 456 6 – Relaxed (after discharging). 457 457 )))|(% style="width:37px" %)U16 458 -|(% style="width:73px" %)**0x2411 -0x2412**|(% style="width:66px" %)2|(% style="width:437px" %)Duration of the battery state (0x2410), seconds|(% style="width:37px" %)U32448 +|(% style="width:73px" %)**0x2411**|(% style="width:66px" %)2|(% style="width:437px" %)Duration of the battery state (0x2410), seconds|(% style="width:37px" %)U32 459 459 460 460 === Holding registers === 461 461