Changes for page 6.2 Modbus protocol
Last modified by Admin on 2025/03/20 12:12
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -227,9 +227,7 @@ 227 227 228 228 bit 26 — signal “External 1”; 229 229 230 -bit 27 — signal “Heater (AUX)”; 231 - 232 -bits 28-31 — not used. 230 +bits 27-31 — not used. 233 233 )))|(% style="width:37px" %)U32 234 234 |(% style="width:73px" %)**0x200B**|(% style="width:66px" %)1|(% style="width:437px" %)((( 235 235 Discrete output signals (bitfield): ... ... @@ -462,6 +462,7 @@ 462 462 (% style="width:617px" %) 463 463 |(% style="width:71px" %)**Register address**|(% style="width:75px" %)**Number of registers**|(% style="width:469px" %)**Content** 464 464 |(% style="width:71px" %)**0x4000**|(% style="width:75px" %)1|(% style="width:469px" %)Address of the BMS Logic device whose parameters should be in the input registers 0x2011-0x20C9 463 +|(% style="width:71px" %)**0x4000-0x4101**|(% style="width:75px" %)2|(% style="width:469px" %)Acknowledgment of errors. Each single bit corresponds to the error (see Errors 1) 465 465 |(% style="width:71px" %)**0x5100**|(% style="width:75px" %)1|(% style="width:469px" %)((( 466 466 Software control of the "Battery cover" signal. Allowable values: 467 467 ... ... @@ -651,5 +651,14 @@ 651 651 652 652 2-65535 – use the physical input "Close Main contactor". 653 653 ))) 653 +|(% style="width:71px" %)**0x5115**|(% style="width:75px" %)1|(% style="width:469px" %)((( 654 +Software control of the "Close External 1" signal. Allowable values: 654 654 656 +0 – clear the signal; 657 + 658 +1 – set the signal; 659 + 660 +2-65535 – use the physical input "Close External 1". 661 +))) 662 + 655 655