... ... @@ -227,9 +227,7 @@
227 227  
228 228  bit 26 — signal “External 1”;
229 229  
230 -bit 27 — signal “Heater (AUX)”;
231 -
232 -bits 26-31 — not used.
230 +bits 27-31 — not used.
233 233  )))|(% style="width:37px" %)U32
234 234  |(% style="width:73px" %)**0x200B**|(% style="width:66px" %)1|(% style="width:437px" %)(((
235 235  Discrete output signals (bitfield):
... ... @@ -462,6 +462,7 @@
462 462  (% style="width:617px" %)
463 463  |(% style="width:71px" %)**Register address**|(% style="width:75px" %)**Number of registers**|(% style="width:469px" %)**Content**
464 464  |(% style="width:71px" %)**0x4000**|(% style="width:75px" %)1|(% style="width:469px" %)Address of the BMS Logic device whose parameters should be in the input registers 0x2011-0x20C9
463 +|(% style="width:71px" %)**0x4000-0x4101**|(% style="width:75px" %)2|(% style="width:469px" %)Acknowledgment of errors. Each single bit corresponds to the error (see Errors 1 bitfield at address 0x2007-0x2008)
465 465  |(% style="width:71px" %)**0x5100**|(% style="width:75px" %)1|(% style="width:469px" %)(((
466 466  Software control of the "Battery cover" signal. Allowable values:
467 467  
... ... @@ -651,5 +651,14 @@
651 651  
652 652  2-65535 – use the physical input "Close Main contactor".
653 653  )))
653 +|(% style="width:71px" %)**0x5115**|(% style="width:75px" %)1|(% style="width:469px" %)(((
654 +Software control of the "Close External 1" signal. Allowable values:
654 654  
656 +0 – clear the signal;
657 +
658 +1 – set the signal;
659 +
660 +2-65535 – use the physical input "Close External 1".
661 +)))
662 +