Changes for page 6.2 Modbus protocol

Last modified by Admin on 2025/03/20 12:12

From version 5.7
edited by Admin
on 2025/02/04 09:39
Change comment: There is no comment for this version
To version 12.1
edited by Admin
on 2025/02/04 10:35
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -227,9 +227,7 @@
227 227  
228 228  bit 26 — signal “External 1”;
229 229  
230 -bit 27 — signal “Heater AUX)”;
231 -
232 -bits 26-31 — not used.
230 +bits 27-31 — not used.
233 233  )))|(% style="width:37px" %)U32
234 234  |(% style="width:73px" %)**0x200B**|(% style="width:66px" %)1|(% style="width:437px" %)(((
235 235  Discrete output signals (bitfield):
... ... @@ -302,7 +302,9 @@
302 302  
303 303  bit 18 — “Power fault”;
304 304  
305 -bits 19-31 — not used.
303 +bit 19 — “Current limit" error;
304 +
305 +bits 20-31 — not used.
306 306  )))|(% style="width:37px" %)U32
307 307  |(% style="width:73px" %)**0x2010**|(% style="width:66px" %)1|(% style="width:437px" %)Address of the BMS Logic device the parameters of which are in registers 0x2011-0x20C9|(% style="width:37px" %)U16
308 308  |(% style="width:73px" %)**0x2011**|(% style="width:66px" %)1|(% style="width:437px" %)(((
... ... @@ -649,5 +649,14 @@
649 649  
650 650  2-65535 – use the physical input "Close Main contactor".
651 651  )))
652 +|(% style="width:71px" %)**0x5115**|(% style="width:75px" %)1|(% style="width:469px" %)(((
653 +Software control of the "Close External 1" signal. Allowable values:
652 652  
655 +0 – clear the signal;
656 +
657 +1 – set the signal;
658 +
659 +2-65535 – use the physical input "Close External 1".
660 +)))
661 +
653 653