... ... @@ -225,7 +225,9 @@
225 225  
226 226  bit 25 — signal “Power up”;
227 227  
228 -bits 26-31 — not used.
228 +bit 26 — signal “External 1”;
229 +
230 +bits 27-31 — not used.
229 229  )))|(% style="width:37px" %)U32
230 230  |(% style="width:73px" %)**0x200B**|(% style="width:66px" %)1|(% style="width:437px" %)(((
231 231  Discrete output signals (bitfield):
... ... @@ -298,7 +298,9 @@
298 298  
299 299  bit 18 — “Power fault”;
300 300  
301 -bits 19-31 — not used.
303 +bit 19 — “Current limit" error;
304 +
305 +bits 20-31 — not used.
302 302  )))|(% style="width:37px" %)U32
303 303  |(% style="width:73px" %)**0x2010**|(% style="width:66px" %)1|(% style="width:437px" %)Address of the BMS Logic device the parameters of which are in registers 0x2011-0x20C9|(% style="width:37px" %)U16
304 304  |(% style="width:73px" %)**0x2011**|(% style="width:66px" %)1|(% style="width:437px" %)(((
... ... @@ -645,5 +645,14 @@
645 645  
646 646  2-65535 – use the physical input "Close Main contactor".
647 647  )))
652 +|(% style="width:71px" %)**0x5115**|(% style="width:75px" %)1|(% style="width:469px" %)(((
653 +Software control of the "Close External 1" signal. Allowable values:
648 648  
655 +0 – clear the signal;
656 +
657 +1 – set the signal;
658 +
659 +2-65535 – use the physical input "Close External 1".
660 +)))
661 +