Changes for page 6.2 Modbus protocol
Last modified by Admin on 2025/03/20 12:12
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -225,7 +225,9 @@ 225 225 226 226 bit 25 — signal “Power up”; 227 227 228 -bits 26-31 — not used. 228 +bit 26 — signal “External 1”; 229 + 230 +bits 27-31 — not used. 229 229 )))|(% style="width:37px" %)U32 230 230 |(% style="width:73px" %)**0x200B**|(% style="width:66px" %)1|(% style="width:437px" %)((( 231 231 Discrete output signals (bitfield): ... ... @@ -257,7 +257,7 @@ 257 257 258 258 bits 6-15 — not used. 259 259 )))|(% style="width:37px" %)U16 260 -|(% style="width:73px" %)**0x200E**|(% style="width:66px" %)2|(% style="width:437px" %)((( 262 +|(% style="width:73px" %)**0x200E-0x200F**|(% style="width:66px" %)2|(% style="width:437px" %)((( 261 261 Errors 2 (bitfield): 262 262 263 263 bit 0 — error "Low temperature (CH)"; ... ... @@ -298,7 +298,9 @@ 298 298 299 299 bit 18 — “Power fault”; 300 300 301 -bits 19-31 — not used. 303 +bit 19 — “Current limit" error; 304 + 305 +bits 20-31 — not used. 302 302 )))|(% style="width:37px" %)U32 303 303 |(% style="width:73px" %)**0x2010**|(% style="width:66px" %)1|(% style="width:437px" %)Address of the BMS Logic device the parameters of which are in registers 0x2011-0x20C9|(% style="width:37px" %)U16 304 304 |(% style="width:73px" %)**0x2011**|(% style="width:66px" %)1|(% style="width:437px" %)((( ... ... @@ -428,8 +428,10 @@ 428 428 |(% style="width:73px" %)**0x217D-0x217E**|(% style="width:66px" %)2|(% style="width:437px" %)Coulomb consumed by the load, A×h|(% style="width:37px" %)REAL32 429 429 |(% style="width:73px" %)**0x21B8**|(% style="width:66px" %)1|(% style="width:437px" %)Flag indicating that some cell is being balanced|(% style="width:37px" %)U16 430 430 |(% style="width:73px" %)**0x21CA-0x21CB**|(% style="width:66px" %)2|(% style="width:437px" %)Average cell voltage, V|(% style="width:37px" %)REAL32 431 -|(% style="width:73px" %)**0x2400**|(% style="width:66px" %)2|(% style="width:437px" %)Current (sensor 1, low range), A|(% style="width:37px" %)REAL32 432 -|(% style="width:73px" %)**0x2402**|(% style="width:66px" %)2|(% style="width:437px" %)Final battery current, A|(% style="width:37px" %)REAL32 435 +|(% style="width:73px" %)**0x2400-0x2401**|(% style="width:66px" %)2|(% style="width:437px" %)Current (sensor 1, low range), A|(% style="width:37px" %)REAL32 436 +|(% style="width:73px" %)((( 437 +**0x2402-0x2403** 438 +)))|(% style="width:66px" %)2|(% style="width:437px" %)Final battery current, A|(% style="width:37px" %)REAL32 433 433 |(% style="width:73px" %)**0x2410**|(% style="width:66px" %)1|(% style="width:437px" %)((( 434 434 Battery state (enumeration): 435 435 ... ... @@ -447,14 +447,14 @@ 447 447 448 448 6 – Relaxed (after discharging). 449 449 )))|(% style="width:37px" %)U16 450 -|(% style="width:73px" %)**0x2411**|(% style="width:66px" %)2|(% style="width:437px" %)Duration of the battery state (0x2410), seconds|(% style="width:37px" %)U32 456 +|(% style="width:73px" %)**0x2411-0x2412**|(% style="width:66px" %)2|(% style="width:437px" %)Duration of the battery state (0x2410), seconds|(% style="width:37px" %)U32 451 451 452 452 === Holding registers === 453 453 454 454 (% style="width:617px" %) 455 -|(% style="width:71px" %)**Register address**|(% style="width:75px" %)**Number of registers**|(% style="width: 469px" %)**Content**456 -|(% style="width:71px" %)**0x4000**|(% style="width:75px" %)1|(% style="width: 469px" %)Address of the BMS Logic device whose parameters should be in the input registers 0x2011-0x20C9457 -|(% style="width:71px" %)**0x5100**|(% style="width:75px" %)1|(% style="width: 469px" %)(((461 +|(% style="width:71px" %)**Register address**|(% style="width:75px" %)**Number of registers**|(% style="width:389px" %)**Content**|(% style="width:87px" %)**Type** 462 +|(% style="width:71px" %)**0x4000**|(% style="width:75px" %)1|(% style="width:389px" %)Address of the BMS Logic device whose parameters should be in the input registers 0x2011-0x20C9|(% style="width:87px" %)U16 463 +|(% style="width:71px" %)**0x5100**|(% style="width:75px" %)1|(% style="width:389px" %)((( 458 458 Software control of the "Battery cover" signal. Allowable values: 459 459 460 460 0 – clear the signal; ... ... @@ -462,8 +462,8 @@ 462 462 1 – set the signal; 463 463 464 464 2-65535 – use the physical input "Battery cover". 465 -))) 466 -|(% style="width:71px" %)**0x5101**|(% style="width:75px" %)1|(% style="width: 469px" %)(((471 +)))|(% style="width:87px" %)U16 472 +|(% style="width:71px" %)**0x5101**|(% style="width:75px" %)1|(% style="width:389px" %)((( 467 467 Software control of the "Charger connected" signal. Allowable values: 468 468 469 469 0 – clear the signal; ... ... @@ -471,8 +471,8 @@ 471 471 1 – set the signal; 472 472 473 473 2-65535 – use the physical input "Charger connected". 474 -))) 475 -|(% style="width:71px" %)**0x5102**|(% style="width:75px" %)1|(% style="width: 469px" %)(((480 +)))|(% style="width:87px" %)U16 481 +|(% style="width:71px" %)**0x5102**|(% style="width:75px" %)1|(% style="width:389px" %)((( 476 476 Software control of the "Power up/down request" signal. Allowable values: 477 477 478 478 0 – clear the signal; ... ... @@ -480,8 +480,8 @@ 480 480 1 – set the signal; 481 481 482 482 2-65535 – use the physical input "Power down request". 483 -))) 484 -|(% style="width:71px" %)**0x5103**|(% style="width:75px" %)1|(% style="width: 469px" %)(((489 +)))|(% style="width:87px" %)U16 490 +|(% style="width:71px" %)**0x5103**|(% style="width:75px" %)1|(% style="width:389px" %)((( 485 485 Software control of the "Inhibit charging" signal. Allowable values: 486 486 487 487 0 – clear the signal; ... ... @@ -489,8 +489,8 @@ 489 489 1 – set the signal; 490 490 491 491 2-65535 – use the physical input "Inhibit charging". 492 -))) 493 -|(% style="width:71px" %)**0x5104**|(% style="width:75px" %)1|(% style="width: 469px" %)(((498 +)))|(% style="width:87px" %)U16 499 +|(% style="width:71px" %)**0x5104**|(% style="width:75px" %)1|(% style="width:389px" %)((( 494 494 Software control of the "Inhibit discharging" signal. Allowable values: 495 495 496 496 0 – clear the signal; ... ... @@ -498,8 +498,8 @@ 498 498 1 – set the signal; 499 499 500 500 2-65535 – use the physical input "Inhibit discharging". 501 -))) 502 -|(% style="width:71px" %)**0x5105**|(% style="width:75px" %)1|(% style="width: 469px" %)(((507 +)))|(% style="width:87px" %)U16 508 +|(% style="width:71px" %)**0x5105**|(% style="width:75px" %)1|(% style="width:389px" %)((( 503 503 Software control of the "CH contactor feedback" signal. Allowable values: 504 504 505 505 0 – clear the signal; ... ... @@ -507,8 +507,8 @@ 507 507 1 – set the signal; 508 508 509 509 2-65535 – use the physical input "Charging contactor feedback". 510 -))) 511 -|(% style="width:71px" %)**0x5106**|(% style="width:75px" %)1|(% style="width: 469px" %)(((516 +)))|(% style="width:87px" %)U16 517 +|(% style="width:71px" %)**0x5106**|(% style="width:75px" %)1|(% style="width:389px" %)((( 512 512 Software control of the "DCH contactor feedback" signal. Allowable values: 513 513 514 514 0 – clear the signal; ... ... @@ -516,8 +516,8 @@ 516 516 1 – set the signal; 517 517 518 518 2-65535 – use the physical input "Discharging contactor feedback". 519 -))) 520 -|(% style="width:71px" %)**0x5107**|(% style="width:75px" %)1|(% style="width: 469px" %)(((525 +)))|(% style="width:87px" %)U16 526 +|(% style="width:71px" %)**0x5107**|(% style="width:75px" %)1|(% style="width:389px" %)((( 521 521 Software control of the "Insulation status" signal. Allowable values: 522 522 523 523 0 – clear the signal; ... ... @@ -525,8 +525,8 @@ 525 525 1 – set the signal; 526 526 527 527 2-65535 – use the physical input "Insulation status". 528 -))) 529 -|(% style="width:71px" %)**0x5108**|(% style="width:75px" %)1|(% style="width: 469px" %)(((534 +)))|(% style="width:87px" %)U16 535 +|(% style="width:71px" %)**0x5108**|(% style="width:75px" %)1|(% style="width:389px" %)((( 530 530 Software control of the "Charge request" signal. Allowable values: 531 531 532 532 0 – clear the signal; ... ... @@ -534,8 +534,8 @@ 534 534 1 – set the signal; 535 535 536 536 2-65535 – use the physical input "Charge request". 537 -))) 538 -|(% style="width:71px" %)**0x5109**|(% style="width:75px" %)1|(% style="width: 469px" %)(((543 +)))|(% style="width:87px" %)U16 544 +|(% style="width:71px" %)**0x5109**|(% style="width:75px" %)1|(% style="width:389px" %)((( 539 539 Software control of the "Precharge request" signal. Allowable values: 540 540 541 541 0 – clear the signal; ... ... @@ -543,8 +543,8 @@ 543 543 1 – set the signal; 544 544 545 545 2-65535 – use the physical input "Precharge request". 546 -))) 547 -|(% style="width:71px" %)**0x510A**|(% style="width:75px" %)1|(% style="width: 469px" %)(((552 +)))|(% style="width:87px" %)U16 553 +|(% style="width:71px" %)**0x510A**|(% style="width:75px" %)1|(% style="width:389px" %)((( 548 548 Software control of the "Discharge request" signal. Allowable values: 549 549 550 550 0 – clear the signal; ... ... @@ -552,8 +552,8 @@ 552 552 1 – set the signal; 553 553 554 554 2-65535 – use the physical input "Discharge request". 555 -))) 556 -|(% style="width:71px" %)**0x510B**|(% style="width:75px" %)1|(% style="width: 469px" %)(((561 +)))|(% style="width:87px" %)U16 562 +|(% style="width:71px" %)**0x510B**|(% style="width:75px" %)1|(% style="width:389px" %)((( 557 557 Software control of the "PCH contactor feedback" signal. Allowable values: 558 558 559 559 0 – clear the signal; ... ... @@ -561,8 +561,8 @@ 561 561 1 – set the signal; 562 562 563 563 2-65535 – use the physical input "PCH contactor feedback". 564 -))) 565 -|(% style="width:71px" %)**0x510C**|(% style="width:75px" %)1|(% style="width: 469px" %)(((570 +)))|(% style="width:87px" %)U16 571 +|(% style="width:71px" %)**0x510C**|(% style="width:75px" %)1|(% style="width:389px" %)((( 566 566 Software control of the "CH/DCH contactor feedback" signal. Allowable values: 567 567 568 568 0 – clear the signal; ... ... @@ -570,8 +570,8 @@ 570 570 1 – set the signal; 571 571 572 572 2-65535 – use the physical input "CH/DCH contactor feedback". 573 -))) 574 -|(% style="width:71px" %)**0x510D**|(% style="width:75px" %)1|(% style="width: 469px" %)(((579 +)))|(% style="width:87px" %)U16 580 +|(% style="width:71px" %)**0x510D**|(% style="width:75px" %)1|(% style="width:389px" %)((( 575 575 Software control of the "Main contactor feedback" signal. Allowable values: 576 576 577 577 0 – clear the signal; ... ... @@ -579,8 +579,8 @@ 579 579 1 – set the signal; 580 580 581 581 2-65535 – use the physical input "Main contactor feedback". 582 -))) 583 -|(% style="width:71px" %)**0x510E**|(% style="width:75px" %)1|(% style="width: 469px" %)(((588 +)))|(% style="width:87px" %)U16 589 +|(% style="width:71px" %)**0x510E**|(% style="width:75px" %)1|(% style="width:389px" %)((( 584 584 Software control of the "Interlock" signal. Allowable values: 585 585 586 586 0 – clear the signal; ... ... @@ -588,8 +588,8 @@ 588 588 1 – set the signal; 589 589 590 590 2-65535 – use the physical input "Interlock". 591 -))) 592 -|(% style="width:71px" %)**0x510F**|(% style="width:75px" %)1|(% style="width: 469px" %)(((597 +)))|(% style="width:87px" %)U16 598 +|(% style="width:71px" %)**0x510F**|(% style="width:75px" %)1|(% style="width:389px" %)((( 593 593 Software control of the "Fuse 1" signal. Allowable values: 594 594 595 595 0 – clear the signal; ... ... @@ -597,8 +597,8 @@ 597 597 1 – set the signal; 598 598 599 599 2-65535 – use the physical input "Fuse 1". 600 -))) 601 -|(% style="width:71px" %)**0x5110**|(% style="width:75px" %)1|(% style="width: 469px" %)(((606 +)))|(% style="width:87px" %)U16 607 +|(% style="width:71px" %)**0x5110**|(% style="width:75px" %)1|(% style="width:389px" %)((( 602 602 Software control of the "Fuse 2" signal. Allowable values: 603 603 604 604 0 – clear the signal; ... ... @@ -606,8 +606,8 @@ 606 606 1 – set the signal; 607 607 608 608 2-65535 – use the physical input "Fuse 2". 609 -))) 610 -|(% style="width:71px" %)**0x5111**|(% style="width:75px" %)1|(% style="width: 469px" %)(((615 +)))|(% style="width:87px" %)U16 616 +|(% style="width:71px" %)**0x5111**|(% style="width:75px" %)1|(% style="width:389px" %)((( 611 611 Software control of the "Fuse 3" signal. Allowable values: 612 612 613 613 0 – clear the signal; ... ... @@ -615,8 +615,8 @@ 615 615 1 – set the signal; 616 616 617 617 2-65535 – use the physical input "Fuse 3". 618 -))) 619 -|(% style="width:71px" %)**0x5112**|(% style="width:75px" %)1|(% style="width: 469px" %)(((624 +)))|(% style="width:87px" %)U16 625 +|(% style="width:71px" %)**0x5112**|(% style="width:75px" %)1|(% style="width:389px" %)((( 620 620 Software control of the "Circuit breaker status" signal. Allowable values: 621 621 622 622 0 – clear the signal; ... ... @@ -624,8 +624,8 @@ 624 624 1 – set the signal; 625 625 626 626 2-65535 – use the physical input "Circuit breaker status". 627 -))) 628 -|(% style="width:71px" %)**0x5113**|(% style="width:75px" %)1|(% style="width: 469px" %)(((633 +)))|(% style="width:87px" %)U16 634 +|(% style="width:71px" %)**0x5113**|(% style="width:75px" %)1|(% style="width:389px" %)((( 629 629 Software control of the "Balancing request" signal. Allowable values: 630 630 631 631 0 – clear the signal; ... ... @@ -633,8 +633,8 @@ 633 633 1 – set the signal; 634 634 635 635 2-65535 – use the physical input "Balancing request". 636 -))) 637 -|(% style="width:71px" %)**0x5114**|(% style="width:75px" %)1|(% style="width: 469px" %)(((642 +)))|(% style="width:87px" %)U16 643 +|(% style="width:71px" %)**0x5114**|(% style="width:75px" %)1|(% style="width:389px" %)((( 638 638 Software control of the "Close Main contactor" signal. Allowable values: 639 639 640 640 0 – clear the signal; ... ... @@ -642,6 +642,15 @@ 642 642 1 – set the signal; 643 643 644 644 2-65535 – use the physical input "Close Main contactor". 645 -))) 651 +)))|(% style="width:87px" %)U16 652 +|(% style="width:71px" %)**0x5115**|(% style="width:75px" %)1|(% style="width:389px" %)((( 653 +Software control of the "Close External 1" signal. Allowable values: 646 646 655 +0 – clear the signal; 656 + 657 +1 – set the signal; 658 + 659 +2-65535 – use the physical input "Close External 1". 660 +)))|(% style="width:87px" %)U16 661 + 647 647