... ... @@ -460,6 +460,7 @@
460 460  (% style="width:617px" %)
461 461  |(% style="width:71px" %)**Register address**|(% style="width:75px" %)**Number of registers**|(% style="width:389px" %)**Content**|(% style="width:87px" %)**Type**
462 462  |(% style="width:71px" %)**0x4000**|(% style="width:75px" %)1|(% style="width:389px" %)Address of the BMS Logic device whose parameters should be in the input registers 0x2011-0x20C9|(% style="width:87px" %)U16
463 +|(% style="width:71px" %)**0x4000-0x4101**|(% style="width:75px" %)2|(% style="width:389px" %)Acknowledgment of errors. Each single bit acknowledges corresponding error (see Errors 1 bitfield at address 0x2007-0x2008)|(% style="width:87px" %)U32
463 463  |(% style="width:71px" %)**0x5100**|(% style="width:75px" %)1|(% style="width:389px" %)(((
464 464  Software control of the "Battery cover" signal. Allowable values:
465 465