Changes for page 6.2 Modbus protocol
Last modified by Admin on 2025/03/20 12:12
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -225,9 +225,7 @@ 225 225 226 226 bit 25 — signal “Power up”; 227 227 228 -bit 26 — signal “External 1”; 229 - 230 -bits 27-31 — not used. 228 +bits 26-31 — not used. 231 231 )))|(% style="width:37px" %)U32 232 232 |(% style="width:73px" %)**0x200B**|(% style="width:66px" %)1|(% style="width:437px" %)((( 233 233 Discrete output signals (bitfield): ... ... @@ -259,7 +259,7 @@ 259 259 260 260 bits 6-15 — not used. 261 261 )))|(% style="width:37px" %)U16 262 -|(% style="width:73px" %)**0x200E -0x200F**|(% style="width:66px" %)2|(% style="width:437px" %)(((260 +|(% style="width:73px" %)**0x200E**|(% style="width:66px" %)2|(% style="width:437px" %)((( 263 263 Errors 2 (bitfield): 264 264 265 265 bit 0 — error "Low temperature (CH)"; ... ... @@ -300,9 +300,7 @@ 300 300 301 301 bit 18 — “Power fault”; 302 302 303 -bit 19 — “Current limit" error; 304 - 305 -bits 20-31 — not used. 301 +bits 19-31 — not used. 306 306 )))|(% style="width:37px" %)U32 307 307 |(% style="width:73px" %)**0x2010**|(% style="width:66px" %)1|(% style="width:437px" %)Address of the BMS Logic device the parameters of which are in registers 0x2011-0x20C9|(% style="width:37px" %)U16 308 308 |(% style="width:73px" %)**0x2011**|(% style="width:66px" %)1|(% style="width:437px" %)((( ... ... @@ -432,10 +432,8 @@ 432 432 |(% style="width:73px" %)**0x217D-0x217E**|(% style="width:66px" %)2|(% style="width:437px" %)Coulomb consumed by the load, A×h|(% style="width:37px" %)REAL32 433 433 |(% style="width:73px" %)**0x21B8**|(% style="width:66px" %)1|(% style="width:437px" %)Flag indicating that some cell is being balanced|(% style="width:37px" %)U16 434 434 |(% style="width:73px" %)**0x21CA-0x21CB**|(% style="width:66px" %)2|(% style="width:437px" %)Average cell voltage, V|(% style="width:37px" %)REAL32 435 -|(% style="width:73px" %)**0x2400-0x2401**|(% style="width:66px" %)2|(% style="width:437px" %)Current (sensor 1, low range), A|(% style="width:37px" %)REAL32 436 -|(% style="width:73px" %)((( 437 -**0x2402-0x2403** 438 -)))|(% style="width:66px" %)2|(% style="width:437px" %)Final battery current, A|(% style="width:37px" %)REAL32 431 +|(% style="width:73px" %)**0x2400**|(% style="width:66px" %)2|(% style="width:437px" %)Current (sensor 1, low range), A|(% style="width:37px" %)REAL32 432 +|(% style="width:73px" %)**0x2402**|(% style="width:66px" %)2|(% style="width:437px" %)Final battery current, A|(% style="width:37px" %)REAL32 439 439 |(% style="width:73px" %)**0x2410**|(% style="width:66px" %)1|(% style="width:437px" %)((( 440 440 Battery state (enumeration): 441 441 ... ... @@ -453,15 +453,14 @@ 453 453 454 454 6 – Relaxed (after discharging). 455 455 )))|(% style="width:37px" %)U16 456 -|(% style="width:73px" %)**0x2411 -0x2412**|(% style="width:66px" %)2|(% style="width:437px" %)Duration of the battery state (0x2410), seconds|(% style="width:37px" %)U32450 +|(% style="width:73px" %)**0x2411**|(% style="width:66px" %)2|(% style="width:437px" %)Duration of the battery state (0x2410), seconds|(% style="width:37px" %)U32 457 457 458 458 === Holding registers === 459 459 460 460 (% style="width:617px" %) 461 -|(% style="width:71px" %)**Register address**|(% style="width:75px" %)**Number of registers**|(% style="width:389px" %)**Content**|(% style="width:87px" %)**Type** 462 -|(% style="width:71px" %)**0x4000**|(% style="width:75px" %)1|(% style="width:389px" %)Address of the BMS Logic device whose parameters should be in the input registers 0x2011-0x20C9|(% style="width:87px" %)U16 463 -|(% style="width:71px" %)**0x4000-0x4101**|(% style="width:75px" %)2|(% style="width:389px" %)Acknowledgment of errors. Each single bit acknowledges corresponding error (see Errors 1 bitfield at address 0x2007-0x2008)|(% style="width:87px" %)U32 464 -|(% style="width:71px" %)**0x5100**|(% style="width:75px" %)1|(% style="width:389px" %)((( 455 +|(% style="width:71px" %)**Register address**|(% style="width:75px" %)**Number of registers**|(% style="width:469px" %)**Content** 456 +|(% style="width:71px" %)**0x4000**|(% style="width:75px" %)1|(% style="width:469px" %)Address of the BMS Logic device whose parameters should be in the input registers 0x2011-0x20C9 457 +|(% style="width:71px" %)**0x5100**|(% style="width:75px" %)1|(% style="width:469px" %)((( 465 465 Software control of the "Battery cover" signal. Allowable values: 466 466 467 467 0 – clear the signal; ... ... @@ -469,8 +469,8 @@ 469 469 1 – set the signal; 470 470 471 471 2-65535 – use the physical input "Battery cover". 472 -))) |(% style="width:87px" %)U16473 -|(% style="width:71px" %)**0x5101**|(% style="width:75px" %)1|(% style="width: 389px" %)(((465 +))) 466 +|(% style="width:71px" %)**0x5101**|(% style="width:75px" %)1|(% style="width:469px" %)((( 474 474 Software control of the "Charger connected" signal. Allowable values: 475 475 476 476 0 – clear the signal; ... ... @@ -478,8 +478,8 @@ 478 478 1 – set the signal; 479 479 480 480 2-65535 – use the physical input "Charger connected". 481 -))) |(% style="width:87px" %)U16482 -|(% style="width:71px" %)**0x5102**|(% style="width:75px" %)1|(% style="width: 389px" %)(((474 +))) 475 +|(% style="width:71px" %)**0x5102**|(% style="width:75px" %)1|(% style="width:469px" %)((( 483 483 Software control of the "Power up/down request" signal. Allowable values: 484 484 485 485 0 – clear the signal; ... ... @@ -487,8 +487,8 @@ 487 487 1 – set the signal; 488 488 489 489 2-65535 – use the physical input "Power down request". 490 -))) |(% style="width:87px" %)U16491 -|(% style="width:71px" %)**0x5103**|(% style="width:75px" %)1|(% style="width: 389px" %)(((483 +))) 484 +|(% style="width:71px" %)**0x5103**|(% style="width:75px" %)1|(% style="width:469px" %)((( 492 492 Software control of the "Inhibit charging" signal. Allowable values: 493 493 494 494 0 – clear the signal; ... ... @@ -496,8 +496,8 @@ 496 496 1 – set the signal; 497 497 498 498 2-65535 – use the physical input "Inhibit charging". 499 -))) |(% style="width:87px" %)U16500 -|(% style="width:71px" %)**0x5104**|(% style="width:75px" %)1|(% style="width: 389px" %)(((492 +))) 493 +|(% style="width:71px" %)**0x5104**|(% style="width:75px" %)1|(% style="width:469px" %)((( 501 501 Software control of the "Inhibit discharging" signal. Allowable values: 502 502 503 503 0 – clear the signal; ... ... @@ -505,8 +505,8 @@ 505 505 1 – set the signal; 506 506 507 507 2-65535 – use the physical input "Inhibit discharging". 508 -))) |(% style="width:87px" %)U16509 -|(% style="width:71px" %)**0x5105**|(% style="width:75px" %)1|(% style="width: 389px" %)(((501 +))) 502 +|(% style="width:71px" %)**0x5105**|(% style="width:75px" %)1|(% style="width:469px" %)((( 510 510 Software control of the "CH contactor feedback" signal. Allowable values: 511 511 512 512 0 – clear the signal; ... ... @@ -514,8 +514,8 @@ 514 514 1 – set the signal; 515 515 516 516 2-65535 – use the physical input "Charging contactor feedback". 517 -))) |(% style="width:87px" %)U16518 -|(% style="width:71px" %)**0x5106**|(% style="width:75px" %)1|(% style="width: 389px" %)(((510 +))) 511 +|(% style="width:71px" %)**0x5106**|(% style="width:75px" %)1|(% style="width:469px" %)((( 519 519 Software control of the "DCH contactor feedback" signal. Allowable values: 520 520 521 521 0 – clear the signal; ... ... @@ -523,8 +523,8 @@ 523 523 1 – set the signal; 524 524 525 525 2-65535 – use the physical input "Discharging contactor feedback". 526 -))) |(% style="width:87px" %)U16527 -|(% style="width:71px" %)**0x5107**|(% style="width:75px" %)1|(% style="width: 389px" %)(((519 +))) 520 +|(% style="width:71px" %)**0x5107**|(% style="width:75px" %)1|(% style="width:469px" %)((( 528 528 Software control of the "Insulation status" signal. Allowable values: 529 529 530 530 0 – clear the signal; ... ... @@ -532,8 +532,8 @@ 532 532 1 – set the signal; 533 533 534 534 2-65535 – use the physical input "Insulation status". 535 -))) |(% style="width:87px" %)U16536 -|(% style="width:71px" %)**0x5108**|(% style="width:75px" %)1|(% style="width: 389px" %)(((528 +))) 529 +|(% style="width:71px" %)**0x5108**|(% style="width:75px" %)1|(% style="width:469px" %)((( 537 537 Software control of the "Charge request" signal. Allowable values: 538 538 539 539 0 – clear the signal; ... ... @@ -541,8 +541,8 @@ 541 541 1 – set the signal; 542 542 543 543 2-65535 – use the physical input "Charge request". 544 -))) |(% style="width:87px" %)U16545 -|(% style="width:71px" %)**0x5109**|(% style="width:75px" %)1|(% style="width: 389px" %)(((537 +))) 538 +|(% style="width:71px" %)**0x5109**|(% style="width:75px" %)1|(% style="width:469px" %)((( 546 546 Software control of the "Precharge request" signal. Allowable values: 547 547 548 548 0 – clear the signal; ... ... @@ -550,8 +550,8 @@ 550 550 1 – set the signal; 551 551 552 552 2-65535 – use the physical input "Precharge request". 553 -))) |(% style="width:87px" %)U16554 -|(% style="width:71px" %)**0x510A**|(% style="width:75px" %)1|(% style="width: 389px" %)(((546 +))) 547 +|(% style="width:71px" %)**0x510A**|(% style="width:75px" %)1|(% style="width:469px" %)((( 555 555 Software control of the "Discharge request" signal. Allowable values: 556 556 557 557 0 – clear the signal; ... ... @@ -559,8 +559,8 @@ 559 559 1 – set the signal; 560 560 561 561 2-65535 – use the physical input "Discharge request". 562 -))) |(% style="width:87px" %)U16563 -|(% style="width:71px" %)**0x510B**|(% style="width:75px" %)1|(% style="width: 389px" %)(((555 +))) 556 +|(% style="width:71px" %)**0x510B**|(% style="width:75px" %)1|(% style="width:469px" %)((( 564 564 Software control of the "PCH contactor feedback" signal. Allowable values: 565 565 566 566 0 – clear the signal; ... ... @@ -568,8 +568,8 @@ 568 568 1 – set the signal; 569 569 570 570 2-65535 – use the physical input "PCH contactor feedback". 571 -))) |(% style="width:87px" %)U16572 -|(% style="width:71px" %)**0x510C**|(% style="width:75px" %)1|(% style="width: 389px" %)(((564 +))) 565 +|(% style="width:71px" %)**0x510C**|(% style="width:75px" %)1|(% style="width:469px" %)((( 573 573 Software control of the "CH/DCH contactor feedback" signal. Allowable values: 574 574 575 575 0 – clear the signal; ... ... @@ -577,8 +577,8 @@ 577 577 1 – set the signal; 578 578 579 579 2-65535 – use the physical input "CH/DCH contactor feedback". 580 -))) |(% style="width:87px" %)U16581 -|(% style="width:71px" %)**0x510D**|(% style="width:75px" %)1|(% style="width: 389px" %)(((573 +))) 574 +|(% style="width:71px" %)**0x510D**|(% style="width:75px" %)1|(% style="width:469px" %)((( 582 582 Software control of the "Main contactor feedback" signal. Allowable values: 583 583 584 584 0 – clear the signal; ... ... @@ -586,8 +586,8 @@ 586 586 1 – set the signal; 587 587 588 588 2-65535 – use the physical input "Main contactor feedback". 589 -))) |(% style="width:87px" %)U16590 -|(% style="width:71px" %)**0x510E**|(% style="width:75px" %)1|(% style="width: 389px" %)(((582 +))) 583 +|(% style="width:71px" %)**0x510E**|(% style="width:75px" %)1|(% style="width:469px" %)((( 591 591 Software control of the "Interlock" signal. Allowable values: 592 592 593 593 0 – clear the signal; ... ... @@ -595,8 +595,8 @@ 595 595 1 – set the signal; 596 596 597 597 2-65535 – use the physical input "Interlock". 598 -))) |(% style="width:87px" %)U16599 -|(% style="width:71px" %)**0x510F**|(% style="width:75px" %)1|(% style="width: 389px" %)(((591 +))) 592 +|(% style="width:71px" %)**0x510F**|(% style="width:75px" %)1|(% style="width:469px" %)((( 600 600 Software control of the "Fuse 1" signal. Allowable values: 601 601 602 602 0 – clear the signal; ... ... @@ -604,8 +604,8 @@ 604 604 1 – set the signal; 605 605 606 606 2-65535 – use the physical input "Fuse 1". 607 -))) |(% style="width:87px" %)U16608 -|(% style="width:71px" %)**0x5110**|(% style="width:75px" %)1|(% style="width: 389px" %)(((600 +))) 601 +|(% style="width:71px" %)**0x5110**|(% style="width:75px" %)1|(% style="width:469px" %)((( 609 609 Software control of the "Fuse 2" signal. Allowable values: 610 610 611 611 0 – clear the signal; ... ... @@ -613,8 +613,8 @@ 613 613 1 – set the signal; 614 614 615 615 2-65535 – use the physical input "Fuse 2". 616 -))) |(% style="width:87px" %)U16617 -|(% style="width:71px" %)**0x5111**|(% style="width:75px" %)1|(% style="width: 389px" %)(((609 +))) 610 +|(% style="width:71px" %)**0x5111**|(% style="width:75px" %)1|(% style="width:469px" %)((( 618 618 Software control of the "Fuse 3" signal. Allowable values: 619 619 620 620 0 – clear the signal; ... ... @@ -622,8 +622,8 @@ 622 622 1 – set the signal; 623 623 624 624 2-65535 – use the physical input "Fuse 3". 625 -))) |(% style="width:87px" %)U16626 -|(% style="width:71px" %)**0x5112**|(% style="width:75px" %)1|(% style="width: 389px" %)(((618 +))) 619 +|(% style="width:71px" %)**0x5112**|(% style="width:75px" %)1|(% style="width:469px" %)((( 627 627 Software control of the "Circuit breaker status" signal. Allowable values: 628 628 629 629 0 – clear the signal; ... ... @@ -631,8 +631,8 @@ 631 631 1 – set the signal; 632 632 633 633 2-65535 – use the physical input "Circuit breaker status". 634 -))) |(% style="width:87px" %)U16635 -|(% style="width:71px" %)**0x5113**|(% style="width:75px" %)1|(% style="width: 389px" %)(((627 +))) 628 +|(% style="width:71px" %)**0x5113**|(% style="width:75px" %)1|(% style="width:469px" %)((( 636 636 Software control of the "Balancing request" signal. Allowable values: 637 637 638 638 0 – clear the signal; ... ... @@ -640,8 +640,8 @@ 640 640 1 – set the signal; 641 641 642 642 2-65535 – use the physical input "Balancing request". 643 -))) |(% style="width:87px" %)U16644 -|(% style="width:71px" %)**0x5114**|(% style="width:75px" %)1|(% style="width: 389px" %)(((636 +))) 637 +|(% style="width:71px" %)**0x5114**|(% style="width:75px" %)1|(% style="width:469px" %)((( 645 645 Software control of the "Close Main contactor" signal. Allowable values: 646 646 647 647 0 – clear the signal; ... ... @@ -649,15 +649,6 @@ 649 649 1 – set the signal; 650 650 651 651 2-65535 – use the physical input "Close Main contactor". 652 -)))|(% style="width:87px" %)U16 653 -|(% style="width:71px" %)**0x5115**|(% style="width:75px" %)1|(% style="width:389px" %)((( 654 -Software control of the "Close External 1" signal. Allowable values: 645 +))) 655 655 656 -0 – clear the signal; 657 - 658 -1 – set the signal; 659 - 660 -2-65535 – use the physical input "Close External 1". 661 -)))|(% style="width:87px" %)U16 662 - 663 663