Changes for page 6.2 Modbus protocol
Last modified by Admin on 2025/07/14 15:28
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -314,7 +314,7 @@ 314 314 315 315 bit 2 — device is ready; 316 316 317 -bit 3 — data from thedeviceis actual;317 +bit 3 — reserved; 318 318 319 319 bit 4 — temperature sensor 1 is present; 320 320 ... ... @@ -460,7 +460,6 @@ 460 460 (% style="width:617px" %) 461 461 |(% style="width:71px" %)**Register address**|(% style="width:75px" %)**Number of registers**|(% style="width:389px" %)**Content**|(% style="width:87px" %)**Type** 462 462 |(% style="width:71px" %)**0x4000**|(% style="width:75px" %)1|(% style="width:389px" %)Address of the BMS Logic device whose parameters should be in the input registers 0x2011-0x20C9|(% style="width:87px" %)U16 463 -|(% style="width:71px" %)**0x4000-0x4101**|(% style="width:75px" %)2|(% style="width:389px" %)Acknowledgment of errors. Each single bit acknowledges corresponding error (see Errors 1 bitfield at address 0x2007-0x2008)|(% style="width:87px" %)U32 464 464 |(% style="width:71px" %)**0x5100**|(% style="width:75px" %)1|(% style="width:389px" %)((( 465 465 Software control of the "Battery cover" signal. Allowable values: 466 466