... ... @@ -225,9 +225,7 @@
225 225  
226 226  bit 25 — signal “Power up”;
227 227  
228 -bit 26 — signal “External 1”;
229 -
230 -bits 27-31 — not used.
228 +bits 26-31 — not used.
231 231  )))|(% style="width:37px" %)U32
232 232  |(% style="width:73px" %)**0x200B**|(% style="width:66px" %)1|(% style="width:437px" %)(((
233 233  Discrete output signals (bitfield):
... ... @@ -259,7 +259,7 @@
259 259  
260 260  bits 6-15 — not used.
261 261  )))|(% style="width:37px" %)U16
262 -|(% style="width:73px" %)**0x200E-0x200F**|(% style="width:66px" %)2|(% style="width:437px" %)(((
260 +|(% style="width:73px" %)**0x200E**|(% style="width:66px" %)2|(% style="width:437px" %)(((
263 263  Errors 2 (bitfield):
264 264  
265 265  bit 0 — error "Low temperature (CH)";
... ... @@ -300,9 +300,7 @@
300 300  
301 301  bit 18 — “Power fault”;
302 302  
303 -bit 19 — “Current limit" error;
304 -
305 -bits 20-31 — not used.
301 +bits 19-31 — not used.
306 306  )))|(% style="width:37px" %)U32
307 307  |(% style="width:73px" %)**0x2010**|(% style="width:66px" %)1|(% style="width:437px" %)Address of the BMS Logic device the parameters of which are in registers 0x2011-0x20C9|(% style="width:37px" %)U16
308 308  |(% style="width:73px" %)**0x2011**|(% style="width:66px" %)1|(% style="width:437px" %)(((
... ... @@ -432,10 +432,8 @@
432 432  |(% style="width:73px" %)**0x217D-0x217E**|(% style="width:66px" %)2|(% style="width:437px" %)Coulomb consumed by the load, A×h|(% style="width:37px" %)REAL32
433 433  |(% style="width:73px" %)**0x21B8**|(% style="width:66px" %)1|(% style="width:437px" %)Flag indicating that some cell is being balanced|(% style="width:37px" %)U16
434 434  |(% style="width:73px" %)**0x21CA-0x21CB**|(% style="width:66px" %)2|(% style="width:437px" %)Average cell voltage, V|(% style="width:37px" %)REAL32
435 -|(% style="width:73px" %)**0x2400-0x2401**|(% style="width:66px" %)2|(% style="width:437px" %)Current (sensor 1, low range), A|(% style="width:37px" %)REAL32
436 -|(% style="width:73px" %)(((
437 -**0x2402-0x2403**
438 -)))|(% style="width:66px" %)2|(% style="width:437px" %)Final battery current, A|(% style="width:37px" %)REAL32
431 +|(% style="width:73px" %)**0x2400**|(% style="width:66px" %)2|(% style="width:437px" %)Current (sensor 1, low range), A|(% style="width:37px" %)REAL32
432 +|(% style="width:73px" %)**0x2402**|(% style="width:66px" %)2|(% style="width:437px" %)Final battery current, A|(% style="width:37px" %)REAL32
439 439  |(% style="width:73px" %)**0x2410**|(% style="width:66px" %)1|(% style="width:437px" %)(((
440 440  Battery state (enumeration):
441 441  
... ... @@ -453,7 +453,7 @@
453 453  
454 454  6 – Relaxed (after discharging).
455 455  )))|(% style="width:37px" %)U16
456 -|(% style="width:73px" %)**0x2411-0x2412**|(% style="width:66px" %)2|(% style="width:437px" %)Duration of the battery state (0x2410), seconds|(% style="width:37px" %)U32
450 +|(% style="width:73px" %)**0x2411**|(% style="width:66px" %)2|(% style="width:437px" %)Duration of the battery state (0x2410), seconds|(% style="width:37px" %)U32
457 457  
458 458  === Holding registers ===
459 459  
... ... @@ -460,7 +460,6 @@
460 460  (% style="width:617px" %)
461 461  |(% style="width:71px" %)**Register address**|(% style="width:75px" %)**Number of registers**|(% style="width:469px" %)**Content**
462 462  |(% style="width:71px" %)**0x4000**|(% style="width:75px" %)1|(% style="width:469px" %)Address of the BMS Logic device whose parameters should be in the input registers 0x2011-0x20C9
463 -|(% style="width:71px" %)**0x4000-0x4101**|(% style="width:75px" %)2|(% style="width:469px" %)Acknowledgment of errors. Each single bit corresponds to the error (see)
464 464  |(% style="width:71px" %)**0x5100**|(% style="width:75px" %)1|(% style="width:469px" %)(((
465 465  Software control of the "Battery cover" signal. Allowable values:
466 466  
... ... @@ -650,14 +650,5 @@
650 650  
651 651  2-65535 – use the physical input "Close Main contactor".
652 652  )))
653 -|(% style="width:71px" %)**0x5115**|(% style="width:75px" %)1|(% style="width:469px" %)(((
654 -Software control of the "Close External 1" signal. Allowable values:
655 655  
656 -0 – clear the signal;
657 -
658 -1 – set the signal;
659 -
660 -2-65535 – use the physical input "Close External 1".
661 -)))
662 -
663 663