Changes for page 6.2 Modbus protocol
Last modified by Admin on 2025/03/20 12:12
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -225,9 +225,7 @@ 225 225 226 226 bit 25 — signal “Power up”; 227 227 228 -bit 26 — signal “External 1”; 229 - 230 -bits 27-31 — not used. 228 +bits 26-31 — not used. 231 231 )))|(% style="width:37px" %)U32 232 232 |(% style="width:73px" %)**0x200B**|(% style="width:66px" %)1|(% style="width:437px" %)((( 233 233 Discrete output signals (bitfield): ... ... @@ -259,7 +259,7 @@ 259 259 260 260 bits 6-15 — not used. 261 261 )))|(% style="width:37px" %)U16 262 -|(% style="width:73px" %)**0x200E -0x200F**|(% style="width:66px" %)2|(% style="width:437px" %)(((260 +|(% style="width:73px" %)**0x200E**|(% style="width:66px" %)2|(% style="width:437px" %)((( 263 263 Errors 2 (bitfield): 264 264 265 265 bit 0 — error "Low temperature (CH)"; ... ... @@ -300,9 +300,7 @@ 300 300 301 301 bit 18 — “Power fault”; 302 302 303 -bit 19 — “Current limit" error; 304 - 305 -bits 20-31 — not used. 301 +bits 19-31 — not used. 306 306 )))|(% style="width:37px" %)U32 307 307 |(% style="width:73px" %)**0x2010**|(% style="width:66px" %)1|(% style="width:437px" %)Address of the BMS Logic device the parameters of which are in registers 0x2011-0x20C9|(% style="width:37px" %)U16 308 308 |(% style="width:73px" %)**0x2011**|(% style="width:66px" %)1|(% style="width:437px" %)((( ... ... @@ -432,10 +432,8 @@ 432 432 |(% style="width:73px" %)**0x217D-0x217E**|(% style="width:66px" %)2|(% style="width:437px" %)Coulomb consumed by the load, A×h|(% style="width:37px" %)REAL32 433 433 |(% style="width:73px" %)**0x21B8**|(% style="width:66px" %)1|(% style="width:437px" %)Flag indicating that some cell is being balanced|(% style="width:37px" %)U16 434 434 |(% style="width:73px" %)**0x21CA-0x21CB**|(% style="width:66px" %)2|(% style="width:437px" %)Average cell voltage, V|(% style="width:37px" %)REAL32 435 -|(% style="width:73px" %)**0x2400-0x2401**|(% style="width:66px" %)2|(% style="width:437px" %)Current (sensor 1, low range), A|(% style="width:37px" %)REAL32 436 -|(% style="width:73px" %)((( 437 -**0x2402-0x2403** 438 -)))|(% style="width:66px" %)2|(% style="width:437px" %)Final battery current, A|(% style="width:37px" %)REAL32 431 +|(% style="width:73px" %)**0x2400**|(% style="width:66px" %)2|(% style="width:437px" %)Current (sensor 1, low range), A|(% style="width:37px" %)REAL32 432 +|(% style="width:73px" %)**0x2402**|(% style="width:66px" %)2|(% style="width:437px" %)Final battery current, A|(% style="width:37px" %)REAL32 439 439 |(% style="width:73px" %)**0x2410**|(% style="width:66px" %)1|(% style="width:437px" %)((( 440 440 Battery state (enumeration): 441 441 ... ... @@ -453,7 +453,7 @@ 453 453 454 454 6 – Relaxed (after discharging). 455 455 )))|(% style="width:37px" %)U16 456 -|(% style="width:73px" %)**0x2411 -0x2412**|(% style="width:66px" %)2|(% style="width:437px" %)Duration of the battery state (0x2410), seconds|(% style="width:37px" %)U32450 +|(% style="width:73px" %)**0x2411**|(% style="width:66px" %)2|(% style="width:437px" %)Duration of the battery state (0x2410), seconds|(% style="width:37px" %)U32 457 457 458 458 === Holding registers === 459 459 ... ... @@ -460,7 +460,6 @@ 460 460 (% style="width:617px" %) 461 461 |(% style="width:71px" %)**Register address**|(% style="width:75px" %)**Number of registers**|(% style="width:469px" %)**Content** 462 462 |(% style="width:71px" %)**0x4000**|(% style="width:75px" %)1|(% style="width:469px" %)Address of the BMS Logic device whose parameters should be in the input registers 0x2011-0x20C9 463 -|(% style="width:71px" %)**0x4000-0x4101**|(% style="width:75px" %)2|(% style="width:469px" %)Acknowledgment of errors. Each single bit corresponds to the error (see) 464 464 |(% style="width:71px" %)**0x5100**|(% style="width:75px" %)1|(% style="width:469px" %)((( 465 465 Software control of the "Battery cover" signal. Allowable values: 466 466 ... ... @@ -650,14 +650,5 @@ 650 650 651 651 2-65535 – use the physical input "Close Main contactor". 652 652 ))) 653 -|(% style="width:71px" %)**0x5115**|(% style="width:75px" %)1|(% style="width:469px" %)((( 654 -Software control of the "Close External 1" signal. Allowable values: 655 655 656 -0 – clear the signal; 657 - 658 -1 – set the signal; 659 - 660 -2-65535 – use the physical input "Close External 1". 661 -))) 662 - 663 663