Changes for page 6.2 Modbus protocol
Last modified by Admin on 2025/03/20 12:12
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -460,7 +460,6 @@ 460 460 (% style="width:617px" %) 461 461 |(% style="width:71px" %)**Register address**|(% style="width:75px" %)**Number of registers**|(% style="width:469px" %)**Content** 462 462 |(% style="width:71px" %)**0x4000**|(% style="width:75px" %)1|(% style="width:469px" %)Address of the BMS Logic device whose parameters should be in the input registers 0x2011-0x20C9 463 -|(% style="width:71px" %)**0x4000-0x4101**|(% style="width:75px" %)2|(% style="width:469px" %)Acknowledgment of errors. Each single bit corresponds to the error (see) 464 464 |(% style="width:71px" %)**0x5100**|(% style="width:75px" %)1|(% style="width:469px" %)((( 465 465 Software control of the "Battery cover" signal. Allowable values: 466 466 ... ... @@ -650,14 +650,5 @@ 650 650 651 651 2-65535 – use the physical input "Close Main contactor". 652 652 ))) 653 -|(% style="width:71px" %)**0x5115**|(% style="width:75px" %)1|(% style="width:469px" %)((( 654 -Software control of the "Close External 1" signal. Allowable values: 655 655 656 -0 – clear the signal; 657 - 658 -1 – set the signal; 659 - 660 -2-65535 – use the physical input "Close External 1". 661 -))) 662 - 663 663