Changes for page 6.2 Modbus protocol

Last modified by Admin on 2025/03/20 12:12

From version 12.2
edited by Admin
on 2025/03/20 12:07
Change comment: There is no comment for this version
To version 11.1
edited by Admin
on 2025/02/04 10:19
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -460,7 +460,6 @@
460 460  (% style="width:617px" %)
461 461  |(% style="width:71px" %)**Register address**|(% style="width:75px" %)**Number of registers**|(% style="width:469px" %)**Content**
462 462  |(% style="width:71px" %)**0x4000**|(% style="width:75px" %)1|(% style="width:469px" %)Address of the BMS Logic device whose parameters should be in the input registers 0x2011-0x20C9
463 -|(% style="width:71px" %)**0x4000-0x4101**|(% style="width:75px" %)2|(% style="width:469px" %)Acknowledgment of errors. Each single bit corresponds to the error (see)
464 464  |(% style="width:71px" %)**0x5100**|(% style="width:75px" %)1|(% style="width:469px" %)(((
465 465  Software control of the "Battery cover" signal. Allowable values:
466 466  
... ... @@ -650,14 +650,5 @@
650 650  
651 651  2-65535 – use the physical input "Close Main contactor".
652 652  )))
653 -|(% style="width:71px" %)**0x5115**|(% style="width:75px" %)1|(% style="width:469px" %)(((
654 -Software control of the "Close External 1" signal. Allowable values:
655 655  
656 -0 – clear the signal;
657 -
658 -1 – set the signal;
659 -
660 -2-65535 – use the physical input "Close External 1".
661 -)))
662 -
663 663