Changes for page 6.2 Modbus protocol
Last modified by Admin on 2025/03/20 12:12
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -458,9 +458,9 @@ 458 458 === Holding registers === 459 459 460 460 (% style="width:617px" %) 461 -|(% style="width:71px" %)**Register address**|(% style="width:75px" %)**Number of registers**|(% style="width: 469px" %)**Content**462 -|(% style="width:71px" %)**0x4000**|(% style="width:75px" %)1|(% style="width: 469px" %)Address of the BMS Logic device whose parameters should be in the input registers 0x2011-0x20C9463 -|(% style="width:71px" %)**0x5100**|(% style="width:75px" %)1|(% style="width: 469px" %)(((461 +|(% style="width:71px" %)**Register address**|(% style="width:75px" %)**Number of registers**|(% style="width:389px" %)**Content**|(% style="width:87px" %)**Type** 462 +|(% style="width:71px" %)**0x4000**|(% style="width:75px" %)1|(% style="width:389px" %)Address of the BMS Logic device whose parameters should be in the input registers 0x2011-0x20C9|(% style="width:87px" %)U16 463 +|(% style="width:71px" %)**0x5100**|(% style="width:75px" %)1|(% style="width:389px" %)((( 464 464 Software control of the "Battery cover" signal. Allowable values: 465 465 466 466 0 – clear the signal; ... ... @@ -468,8 +468,8 @@ 468 468 1 – set the signal; 469 469 470 470 2-65535 – use the physical input "Battery cover". 471 -))) 472 -|(% style="width:71px" %)**0x5101**|(% style="width:75px" %)1|(% style="width: 469px" %)(((471 +)))|(% style="width:87px" %)U16 472 +|(% style="width:71px" %)**0x5101**|(% style="width:75px" %)1|(% style="width:389px" %)((( 473 473 Software control of the "Charger connected" signal. Allowable values: 474 474 475 475 0 – clear the signal; ... ... @@ -477,8 +477,8 @@ 477 477 1 – set the signal; 478 478 479 479 2-65535 – use the physical input "Charger connected". 480 -))) 481 -|(% style="width:71px" %)**0x5102**|(% style="width:75px" %)1|(% style="width: 469px" %)(((480 +)))|(% style="width:87px" %)U16 481 +|(% style="width:71px" %)**0x5102**|(% style="width:75px" %)1|(% style="width:389px" %)((( 482 482 Software control of the "Power up/down request" signal. Allowable values: 483 483 484 484 0 – clear the signal; ... ... @@ -486,8 +486,8 @@ 486 486 1 – set the signal; 487 487 488 488 2-65535 – use the physical input "Power down request". 489 -))) 490 -|(% style="width:71px" %)**0x5103**|(% style="width:75px" %)1|(% style="width: 469px" %)(((489 +)))|(% style="width:87px" %)U16 490 +|(% style="width:71px" %)**0x5103**|(% style="width:75px" %)1|(% style="width:389px" %)((( 491 491 Software control of the "Inhibit charging" signal. Allowable values: 492 492 493 493 0 – clear the signal; ... ... @@ -495,8 +495,8 @@ 495 495 1 – set the signal; 496 496 497 497 2-65535 – use the physical input "Inhibit charging". 498 -))) 499 -|(% style="width:71px" %)**0x5104**|(% style="width:75px" %)1|(% style="width: 469px" %)(((498 +)))|(% style="width:87px" %)U16 499 +|(% style="width:71px" %)**0x5104**|(% style="width:75px" %)1|(% style="width:389px" %)((( 500 500 Software control of the "Inhibit discharging" signal. Allowable values: 501 501 502 502 0 – clear the signal; ... ... @@ -504,8 +504,8 @@ 504 504 1 – set the signal; 505 505 506 506 2-65535 – use the physical input "Inhibit discharging". 507 -))) 508 -|(% style="width:71px" %)**0x5105**|(% style="width:75px" %)1|(% style="width: 469px" %)(((507 +)))|(% style="width:87px" %)U16 508 +|(% style="width:71px" %)**0x5105**|(% style="width:75px" %)1|(% style="width:389px" %)((( 509 509 Software control of the "CH contactor feedback" signal. Allowable values: 510 510 511 511 0 – clear the signal; ... ... @@ -513,8 +513,8 @@ 513 513 1 – set the signal; 514 514 515 515 2-65535 – use the physical input "Charging contactor feedback". 516 -))) 517 -|(% style="width:71px" %)**0x5106**|(% style="width:75px" %)1|(% style="width: 469px" %)(((516 +)))|(% style="width:87px" %)U16 517 +|(% style="width:71px" %)**0x5106**|(% style="width:75px" %)1|(% style="width:389px" %)((( 518 518 Software control of the "DCH contactor feedback" signal. Allowable values: 519 519 520 520 0 – clear the signal; ... ... @@ -522,8 +522,8 @@ 522 522 1 – set the signal; 523 523 524 524 2-65535 – use the physical input "Discharging contactor feedback". 525 -))) 526 -|(% style="width:71px" %)**0x5107**|(% style="width:75px" %)1|(% style="width: 469px" %)(((525 +)))|(% style="width:87px" %)U16 526 +|(% style="width:71px" %)**0x5107**|(% style="width:75px" %)1|(% style="width:389px" %)((( 527 527 Software control of the "Insulation status" signal. Allowable values: 528 528 529 529 0 – clear the signal; ... ... @@ -531,8 +531,8 @@ 531 531 1 – set the signal; 532 532 533 533 2-65535 – use the physical input "Insulation status". 534 -))) 535 -|(% style="width:71px" %)**0x5108**|(% style="width:75px" %)1|(% style="width: 469px" %)(((534 +)))|(% style="width:87px" %)U16 535 +|(% style="width:71px" %)**0x5108**|(% style="width:75px" %)1|(% style="width:389px" %)((( 536 536 Software control of the "Charge request" signal. Allowable values: 537 537 538 538 0 – clear the signal; ... ... @@ -540,8 +540,8 @@ 540 540 1 – set the signal; 541 541 542 542 2-65535 – use the physical input "Charge request". 543 -))) 544 -|(% style="width:71px" %)**0x5109**|(% style="width:75px" %)1|(% style="width: 469px" %)(((543 +)))|(% style="width:87px" %)U16 544 +|(% style="width:71px" %)**0x5109**|(% style="width:75px" %)1|(% style="width:389px" %)((( 545 545 Software control of the "Precharge request" signal. Allowable values: 546 546 547 547 0 – clear the signal; ... ... @@ -549,8 +549,8 @@ 549 549 1 – set the signal; 550 550 551 551 2-65535 – use the physical input "Precharge request". 552 -))) 553 -|(% style="width:71px" %)**0x510A**|(% style="width:75px" %)1|(% style="width: 469px" %)(((552 +)))|(% style="width:87px" %)U16 553 +|(% style="width:71px" %)**0x510A**|(% style="width:75px" %)1|(% style="width:389px" %)((( 554 554 Software control of the "Discharge request" signal. Allowable values: 555 555 556 556 0 – clear the signal; ... ... @@ -558,8 +558,8 @@ 558 558 1 – set the signal; 559 559 560 560 2-65535 – use the physical input "Discharge request". 561 -))) 562 -|(% style="width:71px" %)**0x510B**|(% style="width:75px" %)1|(% style="width: 469px" %)(((561 +)))|(% style="width:87px" %)U16 562 +|(% style="width:71px" %)**0x510B**|(% style="width:75px" %)1|(% style="width:389px" %)((( 563 563 Software control of the "PCH contactor feedback" signal. Allowable values: 564 564 565 565 0 – clear the signal; ... ... @@ -567,8 +567,8 @@ 567 567 1 – set the signal; 568 568 569 569 2-65535 – use the physical input "PCH contactor feedback". 570 -))) 571 -|(% style="width:71px" %)**0x510C**|(% style="width:75px" %)1|(% style="width: 469px" %)(((570 +)))|(% style="width:87px" %)U16 571 +|(% style="width:71px" %)**0x510C**|(% style="width:75px" %)1|(% style="width:389px" %)((( 572 572 Software control of the "CH/DCH contactor feedback" signal. Allowable values: 573 573 574 574 0 – clear the signal; ... ... @@ -576,8 +576,8 @@ 576 576 1 – set the signal; 577 577 578 578 2-65535 – use the physical input "CH/DCH contactor feedback". 579 -))) 580 -|(% style="width:71px" %)**0x510D**|(% style="width:75px" %)1|(% style="width: 469px" %)(((579 +)))|(% style="width:87px" %)U16 580 +|(% style="width:71px" %)**0x510D**|(% style="width:75px" %)1|(% style="width:389px" %)((( 581 581 Software control of the "Main contactor feedback" signal. Allowable values: 582 582 583 583 0 – clear the signal; ... ... @@ -585,8 +585,8 @@ 585 585 1 – set the signal; 586 586 587 587 2-65535 – use the physical input "Main contactor feedback". 588 -))) 589 -|(% style="width:71px" %)**0x510E**|(% style="width:75px" %)1|(% style="width: 469px" %)(((588 +)))|(% style="width:87px" %)U16 589 +|(% style="width:71px" %)**0x510E**|(% style="width:75px" %)1|(% style="width:389px" %)((( 590 590 Software control of the "Interlock" signal. Allowable values: 591 591 592 592 0 – clear the signal; ... ... @@ -594,8 +594,8 @@ 594 594 1 – set the signal; 595 595 596 596 2-65535 – use the physical input "Interlock". 597 -))) 598 -|(% style="width:71px" %)**0x510F**|(% style="width:75px" %)1|(% style="width: 469px" %)(((597 +)))|(% style="width:87px" %)U16 598 +|(% style="width:71px" %)**0x510F**|(% style="width:75px" %)1|(% style="width:389px" %)((( 599 599 Software control of the "Fuse 1" signal. Allowable values: 600 600 601 601 0 – clear the signal; ... ... @@ -603,8 +603,8 @@ 603 603 1 – set the signal; 604 604 605 605 2-65535 – use the physical input "Fuse 1". 606 -))) 607 -|(% style="width:71px" %)**0x5110**|(% style="width:75px" %)1|(% style="width: 469px" %)(((606 +)))|(% style="width:87px" %)U16 607 +|(% style="width:71px" %)**0x5110**|(% style="width:75px" %)1|(% style="width:389px" %)((( 608 608 Software control of the "Fuse 2" signal. Allowable values: 609 609 610 610 0 – clear the signal; ... ... @@ -612,8 +612,8 @@ 612 612 1 – set the signal; 613 613 614 614 2-65535 – use the physical input "Fuse 2". 615 -))) 616 -|(% style="width:71px" %)**0x5111**|(% style="width:75px" %)1|(% style="width: 469px" %)(((615 +)))|(% style="width:87px" %)U16 616 +|(% style="width:71px" %)**0x5111**|(% style="width:75px" %)1|(% style="width:389px" %)((( 617 617 Software control of the "Fuse 3" signal. Allowable values: 618 618 619 619 0 – clear the signal; ... ... @@ -621,8 +621,8 @@ 621 621 1 – set the signal; 622 622 623 623 2-65535 – use the physical input "Fuse 3". 624 -))) 625 -|(% style="width:71px" %)**0x5112**|(% style="width:75px" %)1|(% style="width: 469px" %)(((624 +)))|(% style="width:87px" %)U16 625 +|(% style="width:71px" %)**0x5112**|(% style="width:75px" %)1|(% style="width:389px" %)((( 626 626 Software control of the "Circuit breaker status" signal. Allowable values: 627 627 628 628 0 – clear the signal; ... ... @@ -630,8 +630,8 @@ 630 630 1 – set the signal; 631 631 632 632 2-65535 – use the physical input "Circuit breaker status". 633 -))) 634 -|(% style="width:71px" %)**0x5113**|(% style="width:75px" %)1|(% style="width: 469px" %)(((633 +)))|(% style="width:87px" %)U16 634 +|(% style="width:71px" %)**0x5113**|(% style="width:75px" %)1|(% style="width:389px" %)((( 635 635 Software control of the "Balancing request" signal. Allowable values: 636 636 637 637 0 – clear the signal; ... ... @@ -639,8 +639,8 @@ 639 639 1 – set the signal; 640 640 641 641 2-65535 – use the physical input "Balancing request". 642 -))) 643 -|(% style="width:71px" %)**0x5114**|(% style="width:75px" %)1|(% style="width: 469px" %)(((642 +)))|(% style="width:87px" %)U16 643 +|(% style="width:71px" %)**0x5114**|(% style="width:75px" %)1|(% style="width:389px" %)((( 644 644 Software control of the "Close Main contactor" signal. Allowable values: 645 645 646 646 0 – clear the signal; ... ... @@ -648,8 +648,8 @@ 648 648 1 – set the signal; 649 649 650 650 2-65535 – use the physical input "Close Main contactor". 651 -))) 652 -|(% style="width:71px" %)**0x5115**|(% style="width:75px" %)1|(% style="width: 469px" %)(((651 +)))|(% style="width:87px" %)U16 652 +|(% style="width:71px" %)**0x5115**|(% style="width:75px" %)1|(% style="width:389px" %)((( 653 653 Software control of the "Close External 1" signal. Allowable values: 654 654 655 655 0 – clear the signal; ... ... @@ -657,6 +657,6 @@ 657 657 1 – set the signal; 658 658 659 659 2-65535 – use the physical input "Close External 1". 660 -))) 660 +)))|(% style="width:87px" %)U16 661 661 662 662