... ... @@ -460,6 +460,7 @@
460 460  (% style="width:617px" %)
461 461  |(% style="width:71px" %)**Register address**|(% style="width:75px" %)**Number of registers**|(% style="width:469px" %)**Content**
462 462  |(% style="width:71px" %)**0x4000**|(% style="width:75px" %)1|(% style="width:469px" %)Address of the BMS Logic device whose parameters should be in the input registers 0x2011-0x20C9
463 +|(% style="width:71px" %)**0x4000-0x4101**|(% style="width:75px" %)2|(% style="width:469px" %)Acknowledgment of errors. Each single bit corresponds to the error (see Errors 1)
463 463  |(% style="width:71px" %)**0x5100**|(% style="width:75px" %)1|(% style="width:469px" %)(((
464 464  Software control of the "Battery cover" signal. Allowable values:
465 465  
... ... @@ -649,5 +649,14 @@
649 649  
650 650  2-65535 – use the physical input "Close Main contactor".
651 651  )))
653 +|(% style="width:71px" %)**0x5115**|(% style="width:75px" %)1|(% style="width:469px" %)(((
654 +Software control of the "Close External 1" signal. Allowable values:
652 652  
656 +0 – clear the signal;
657 +
658 +1 – set the signal;
659 +
660 +2-65535 – use the physical input "Close External 1".
661 +)))
662 +