Changes for page 5. Firmware update

Last modified by Admin on 2025/02/17 15:00

From version 6.2
edited by Admin
on 2024/12/26 17:11
Change comment: There is no comment for this version
To version 11.1
edited by Admin
on 2025/02/17 15:00
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -7,15 +7,17 @@
7 7  
8 8  Updating the BMS Main 3 / BMS Main 3X firmware can be done in the following ways:
9 9  
10 -* via unified bootloader (available via USB only)
10 +* via bootloader (available via USB only);
11 11  * via device configuration interface (available via USB, CAN and TCP).
12 12  
13 13  The following hardware and software are required:
14 14  
15 15  * ElectricDeviceMonitor application for Windows OS which is used for configuring the BMS Main 3 / BMS Main 3X;
16 -* USB/CAN adapter for updating via CAN bus;
17 -* USB cable for updating via Serial port;
18 -* BMS Wi-Fi or BMS LANmodule installed if updating via TCP;
16 +* Communication device:
17 +** USB/CAN adapter — for updating via CAN bus;
18 +** USB-mini cable — for updating via USB;
19 +** BMS Wi-Fi or BMS LANmodule installed on BMS Main 3 — for update via TCP;
20 +* SD card — for updating via configuration interface;
19 19  * Firmware file (must be in .bin format).
20 20  
21 21  == Updating via bootloader ==
... ... @@ -42,13 +42,12 @@
42 42  
43 43  **2. Upload the firmware.**
44 44  
45 -2.1 Launch the ElectricDeviceMonitor’s Updater module:
47 +2.1 Launch the ElectricDeviceMonitor’s Unified bootloader module:
46 46  
47 47  [[image:1735232992154-566.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="340" width="450"]]
48 48  
49 -[[image:1735233018575-198.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="316" width="300"]]2.2 From the drop-down menu of the Updater window, select the method of connecting to the BMS Main 3 / BMS Main 3X and configure the connection parameters (the "Settings..." button).
51 +[[image:1735233018575-198.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="316" width="300"]]2.2 From the drop-down menu of the Unified bootloader window, select the method of connecting to the BMS Main 3 / BMS Main 3X and configure the connection parameters (the "Settings..." button).
50 50  
51 -
52 52  * **USB connection**: select the connection method “Serial port transport”, click the “Settings...” button. In the window that appears, select the COM port through which the PC connects to the device (the baud rate can be set to any):
53 53  
54 54  [[image:1733406142376-880.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]]