Changes for page 5. Firmware update

Last modified by Admin on 2025/02/17 15:00

From version 6.1
edited by Admin
on 2024/12/26 17:10
Change comment: Uploaded new attachment "1735233018575-198.png", version {1}
To version 7.1
edited by Admin
on 2024/12/26 17:13
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -14,8 +14,8 @@
14 14  
15 15  * ElectricDeviceMonitor application for Windows OS which is used for configuring the BMS Main 3 / BMS Main 3X;
16 16  * USB/CAN adapter for updating via CAN bus;
17 -* USB cable for updating via COM port;
18 -* BMS Wi-Fi or BMS LANmodule installed if updating via TCP;
17 +* USB cable for updating via Serial port;
18 +* BMS Wi-Fi or BMS LANmodule installed on BMS Main 3 if updating via TCP;
19 19  * Firmware file (must be in .bin format).
20 20  
21 21  == Updating via bootloader ==
... ... @@ -42,26 +42,17 @@
42 42  
43 43  **2. Upload the firmware.**
44 44  
45 -2.1 Launch the ElectricDeviceMonitor’s Updater module:
45 +2.1 Launch the ElectricDeviceMonitor’s Unified bootloader module:
46 46  
47 47  [[image:1735232992154-566.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="340" width="450"]]
48 48  
49 +[[image:1735233018575-198.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="316" width="300"]]2.2 From the drop-down menu of the Unified bootloader window, select the method of connecting to the BMS Main 3 / BMS Main 3X and configure the connection parameters (the "Settings..." button).
49 49  
50 50  
51 -2.2 From the drop-down menu of the Updater window, select the method of connecting to the BMS Main 3 / BMS Main 3X and configure the connection parameters (the "Settings..." button).
52 -
53 53  * **USB connection**: select the connection method “Serial port transport”, click the “Settings...” button. In the window that appears, select the COM port through which the PC connects to the device (the baud rate can be set to any):
54 54  
55 55  [[image:1733406142376-880.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]]
56 56  
57 -* **CAN connection**: select the "CAN transport" connection method, click the "Settings..." button. In the window that appears, select the USB-CAN adapter with which the main firmware will be loaded, and specify the baud rate via the CAN bus:
58 -
59 -[[image:1733406142376-284.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]]
60 -
61 -* **RS-485 connection**: select the connection method “Serial port transport”, click the “Settings...” button. In the window that appears, select the COM port through which the PC connects to the device, and specify the baud rate for the COM port:
62 -
63 -[[image:1733406142377-550.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]]
64 -
65 65  2.3 Click the "Browse..." button and select the *.bin file with the main firmware.
66 66  
67 67  2.4 Click the “Update” button **while the device is in bootloader mode**. The process of loading the new firmware into the device memory will begin.
... ... @@ -75,7 +75,7 @@
75 75  
76 76  ~1. Perform connection to the device and user authentication in the Unified monitor.
77 77  
78 -2. Select the “Device → Update firmware…” menu item. In the appeared window, click the “Browse…” button and specify the path to the file with the new main firmware (*.srec).
69 +2. Select the “Device → Update firmware…” menu item. In the appeared window, click the “Browse…” button and specify the path to the file with the new main firmware (*.bin).
79 79  
80 80  [[image:1733921914002-572.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]]
81 81