... ... @@ -7,27 +7,28 @@
7 7  
8 8  Updating the BMS Main 3 / BMS Main 3X firmware can be done in the following ways:
9 9  
10 -* via unified bootloader (available via USB only)
11 -* via device configuration interface (available via USB, CAN and TCP).
10 +* via USB;
11 +* via CAN bus;
12 +* via RS-485 bus;
13 +* using the device configuration interface (available via USB, CAN, and Wi-Fi).
12 12  
13 13  The following hardware and software are required:
14 14  
15 -* ElectricDeviceMonitor application for Windows OS which is used for configuring the BMS Main 3 / BMS Main 3X;
16 -* USB/CAN adapter for updating via CAN bus;
17 -* USB cable for updating via COM port;
18 -* BMS Wi-Fi or BMS LANmodule installed if updating via TCP;
19 -* Firmware file (must be in .bin format).
17 +* ElectricDeviceMonitor application for Windows OS which is used for configuring the BMS Main 3 / BMS Main 3X.
18 +* USB/CAN adapter for updating via CAN bus.
19 +* USB/RS-485 adapter for updating via RS-485 bus.
20 +* Firmware file (must be in Motorola S-record format).
20 20  
21 -== Updating via bootloader ==
22 -
23 23  Firmware updating includes two steps:
24 24  
25 25  * starting the bootloader;
26 26  * uploading the firmware file to the BMS Main flash memory.
27 27  
27 +== Updating via USB, CAN, RS-485 ==
28 +
28 28  **~1. Start the device bootloader.**
29 29  
30 -* **Method 1**: using the Unified monitor of the ElectricDeviceMonitor program, connect to the BMS Main 3 / BMS Main 3X device via the USB, CAN or TCP connection. Next, in the monitor program, click the "Device → Go to bootloader" menu item:
31 +* **Method 1**: using the Unified monitor of the ElectricDeviceMonitor program, connect to the BMS Main 3 / BMS Main 3X device via the USB or CAN connection. Next, in the monitor program, click the "Device → Go to bootloader" menu item:
31 31  
32 32  [[image:1733921869101-125.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]]
33 33  
... ... @@ -44,9 +44,10 @@
44 44  
45 45  2.1 Launch the ElectricDeviceMonitor’s Updater module:
46 46  
47 -[[image:1735232992154-566.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="340" width="450"]]
48 +[[image:1733406691402-715.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="315" width="417"]]
48 48  
49 49  
51 +[[image:1733406142375-809.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="333" width="312"]]
50 50  
51 51  2.2 From the drop-down menu of the Updater window, select the method of connecting to the BMS Main 3 / BMS Main 3X and configure the connection parameters (the "Settings..." button).
52 52  