Changes for page 5. Firmware update

Last modified by Admin on 2025/02/17 15:00

From version 4.2
edited by Admin
on 2024/12/26 17:07
Change comment: There is no comment for this version
To version 5.2
edited by Admin
on 2024/12/26 17:10
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -12,21 +12,22 @@
12 12  
13 13  The following hardware and software are required:
14 14  
15 -* ElectricDeviceMonitor application for Windows OS which is used for configuring the BMS Main 3 / BMS Main 3X.
16 -* USB/CAN adapter for updating via CAN bus.
17 -* USB  for updating via RS-485 bus.
18 -* Firmware file (must be in Motorola S-record format).
15 +* ElectricDeviceMonitor application for Windows OS which is used for configuring the BMS Main 3 / BMS Main 3X;
16 +* USB/CAN adapter for updating via CAN bus;
17 +* USB cable for updating via COM port;
18 +* BMS Wi-Fi or BMS LANmodule installed if updating via TCP;
19 +* Firmware file (must be in .bin format).
19 19  
21 +== Updating via bootloader ==
22 +
20 20  Firmware updating includes two steps:
21 21  
22 22  * starting the bootloader;
23 23  * uploading the firmware file to the BMS Main flash memory.
24 24  
25 -== Updating via USB, CAN, RS-485 ==
26 -
27 27  **~1. Start the device bootloader.**
28 28  
29 -* **Method 1**: using the Unified monitor of the ElectricDeviceMonitor program, connect to the BMS Main 3 / BMS Main 3X device via the USB or CAN connection. Next, in the monitor program, click the "Device → Go to bootloader" menu item:
30 +* **Method 1**: using the Unified monitor of the ElectricDeviceMonitor program, connect to the BMS Main 3 / BMS Main 3X device via the USB, CAN or TCP connection. Next, in the monitor program, click the "Device → Go to bootloader" menu item:
30 30  
31 31  [[image:1733921869101-125.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]]
32 32  
... ... @@ -43,10 +43,9 @@
43 43  
44 44  2.1 Launch the ElectricDeviceMonitor’s Updater module:
45 45  
46 -[[image:1733406691402-715.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="315" width="417"]]
47 +[[image:1735232992154-566.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="340" width="450"]]
47 47  
48 48  
49 -[[image:1733406142375-809.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="333" width="312"]]
50 50  
51 51  2.2 From the drop-down menu of the Updater window, select the method of connecting to the BMS Main 3 / BMS Main 3X and configure the connection parameters (the "Settings..." button).
52 52  
1735232992154-566.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +32.1 KB
Content