Changes for page 5. Firmware update

Last modified by Admin on 2025/02/17 15:00

From version 3.1
edited by Admin
on 2024/12/11 12:58
Change comment: There is no comment for this version
To version 4.2
edited by Admin
on 2024/12/26 17:07
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -3,20 +3,18 @@
3 3  
4 4  == Introduction ==
5 5  
6 -This document describes the steps for updating the BMS Main 3 firmware.
6 +This document describes the steps for updating the BMS Main 3 / BMS Main 3X firmware.
7 7  
8 -Updating the BMS Mini firmware can be done in the following ways:
8 +Updating the BMS Main 3 / BMS Main 3X firmware can be done in the following ways:
9 9  
10 -* via USB;
11 -* via CAN bus;
12 -* via RS-485 bus;
13 -* using the device configuration interface (available via USB, CAN, and Wi-Fi).
10 +* via unified bootloader (available via USB only)
11 +* via device configuration interface (available via USB, CAN and TCP).
14 14  
15 15  The following hardware and software are required:
16 16  
17 -* ElectricDeviceMonitor application for Windows OS which is used for configuring the BMS Mini 2 / Mini S.
15 +* ElectricDeviceMonitor application for Windows OS which is used for configuring the BMS Main 3 / BMS Main 3X.
18 18  * USB/CAN adapter for updating via CAN bus.
19 -* USB/RS-485 adapter for updating via RS-485 bus.
17 +* USB  for updating via RS-485 bus.
20 20  * Firmware file (must be in Motorola S-record format).
21 21  
22 22  Firmware updating includes two steps:
... ... @@ -28,7 +28,7 @@
28 28  
29 29  **~1. Start the device bootloader.**
30 30  
31 -* **Method 1**: using the Unified monitor of the ElectricDeviceMonitor program, connect to the BMS Mini device via the USB or CAN connection. Next, in the monitor program, click the "Device → Go to bootloader" menu item:
29 +* **Method 1**: using the Unified monitor of the ElectricDeviceMonitor program, connect to the BMS Main 3 / BMS Main 3X device via the USB or CAN connection. Next, in the monitor program, click the "Device → Go to bootloader" menu item:
32 32  
33 33  [[image:1733921869101-125.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true"]]
34 34  
... ... @@ -50,7 +50,7 @@
50 50  
51 51  [[image:1733406142375-809.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="333" width="312"]]
52 52  
53 -2.2 From the drop-down menu of the Updater window, select the method of connecting to the BMS Mini device and configure the connection parameters (the "Settings..." button).
51 +2.2 From the drop-down menu of the Updater window, select the method of connecting to the BMS Main 3 / BMS Main 3X and configure the connection parameters (the "Settings..." button).
54 54  
55 55  * **USB connection**: select the connection method “Serial port transport”, click the “Settings...” button. In the window that appears, select the COM port through which the PC connects to the device (the baud rate can be set to any):
56 56