10 10  
11 11  In this section:
12 12  
13 -* Devices: Present 1-32, Devices: Present 33-40 – bitfield containing Logics found during BMS initialization;
14 -*
15 -* Logic 1 - Logic 40 – a section with relative Logic data:
16 -**
13 +* Devices: Present 1-32, Devices: Present 33-40 – bitfields indicating Logics that were found during BMS initialization;
14 +* Devices: Online 1-32, Devices: Online 33-40 – bitfields indicating Logics that are online at that moment;
15 +* Devices: Temperature – information about all Logics temperature;
16 +* Logic 1 - Logic 40 – a section with Logic data with relative cells information:
17 +** Green indicator – cell is connected to BMS Logic;
18 +** Red indicator – cell is balancing;
19 +** SOC indicator, %;
20 +** Cell voltage, V;
21 +** Cell temperature, ºC;
22 +** Cell resistance, mOhm;
23 +** Indication of connected temperature sensor: black – connected, red – not connected.