Changes for page 4.3 Logics

Last modified by Admin on 2024/12/26 16:29

From version 1.1
edited by Admin
on 2024/12/05 12:53
Change comment: There is no comment for this version
To version 7.6
edited by Admin
on 2024/12/26 16:28
Change comment: There is no comment for this version

Summary

Details

Page properties
Title
... ... @@ -1,1 +1,1 @@
1 -4.3 Cells and error simulation
1 +4.3 Logics
Parent
... ... @@ -1,1 +1,1 @@
1 -drafts.bms-main-3.4\. Monitoring.WebHome
1 +Battery management systems.BMS Main 3.4\. Monitoring.WebHome
Content
... ... @@ -1,12 +1,23 @@
1 -The summary information on all battery cells can be found in the "Logics" section.
1 +(% data-numbered-headings-start="4" style="--numbered-headings-start: 3;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
2 += Monitoring =
2 2  
3 -[[image:1733403116280-156.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="129" width="800"]]
4 +(% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
5 +== Cells ==
4 4  
7 +The summary information on all battery cells can be found in the "Logics" section.
5 5  
6 -Simulation of device errors is carried out in the "Error simulation" section:
9 +[[image:1735230232575-274.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="463" width="800"]]
7 7  
8 -[[image:1733403146552-199.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="407" width="800"]]
9 -
10 10  In this section:
11 11  
12 -* Errors 1, Errors 2 – bitfields with flags for simulating corresponding error.
13 +* Devices: Present 1-32, Devices: Present 33-40 – bitfields indicating Logics that were found during BMS initialization;
14 +* Devices: Online 1-32, Devices: Online 33-40 – bitfields indicating Logics that are online at that moment;
15 +* Devices: Temperature – information about all Logics temperature;
16 +* Logic 1 - Logic 40 – a section with Logic data with relative cells information:
17 +** Green indicator – cell is connected to BMS Logic;
18 +** Red indicator – cell is balancing;
19 +** SOC indicator, %;
20 +** Cell voltage, V;
21 +** Cell temperature,
22 +
23 +
1735230195793-394.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +133.7 KB
Content
1735230232575-274.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +129.1 KB
Content