Changes for page 4.2 Battery
Last modified by Admin on 2025/06/19 11:13
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -4,28 +4,27 @@ 4 4 (% data-numbered-headings-start="2" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 5 5 == Battery == 6 6 7 - Параметрыбатареисведенывраздел«Battery»:7 +Battery parameters are summarized in the "Battery" section: 8 8 9 9 [[image:1735228916836-719.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="370" width="800"]] 10 10 11 - Вэтомразделе:11 +In this section: 12 12 13 -* Voltage – напряжение батареи, В; 14 -* Current – ток батареи, А; 15 -* Internal resistance – сопротивление батареи, Ом; 16 -* Main voltage – напряжение питания устройства, В; 17 -* Power switch voltage – напряжение питания силовых ключей, В; 18 -* Board temperature – температура устройства, °C; 19 -* Board humidity – влажность измеренная внутренним датчиком устройства, °C; 20 -* Temperature 1, 2 – температура, измеренная внешним датчиком, °C; 21 -* Number of Logic devices – количество подключенных устройств BMS Logic; 22 -* Logic command rate – скорость обмена с устройствами BMS Logic, ком./с; 23 -* Minimum Logic temperature – минимальная температура среди устройств BMS Logic, °C; 24 -* Min. Logic temp.: Logic index – номер устройства Logic, имеющего минимальную температуру; 25 -* Maximum Logic temperature – максимальная температура среди устройств BMS Logic, °C; 26 -* Max. Logic temp.: Logic index – номер устройства Logic, имеющего максимальную температуру; 27 -* Number of cells – 28 -* количество подключенных ячеек; 13 +* Voltage – voltage of the battery, V; 14 +* Current – current of the battery, A; 15 +* Internal resistance – internal resistance of the battery, Ohm; 16 +* Main voltage – supply voltage on the BMS, V; 17 +* Power switch voltage – supply voltage on the power switches, V; 18 +* Board temperature – internal temperature of the BMS, °C; 19 +* Board humidity – relative humidity measured by the BMS, %; 20 +* Temperature 1, 2 – temperature measured by the external temperature sensors, °C; 21 +* Number of Logic devices – number of connected Logic devices; 22 +* Logic command rate – number of commands transmitted to Logic devices, com/s; 23 +* Minimum Logic temperature – minimum temperature among Logic devices, °C; 24 +* Min. Logic temp.: Logic index – number of Logic with minimum temperature; 25 +* Maximum Logic temperature – minimum temperature among Logic devices, °C; 26 +* Max. Logic temp.: Logic index – number of Logic with maximum temperature; 27 +* Number of cells – number of connected cells; 29 29 * Average cell temperature, °C; 30 30 * Minimum cell temperature, °C; 31 31 * Min. cell temp.: Logic index – number of Logic with minimum cell temperature; ... ... @@ -66,14 +66,14 @@ 66 66 * Discharge current limit – maximum allowed discharge current of the battery, A; 67 67 * High voltage 1 – voltage before the contactors, V; 68 68 * High voltage 2 – voltage after the contactors, V; 69 -* Work charge+ –amount of charge received from charger (positive direction) since device startup, Ah;70 -* Work charge- –amount of charge transmitted to the load (negative direction) since device startup, Ah;71 -* Work energy+ –amount of energy received from charger (positive direction) since device startup, Wh;72 -* Work energy- –amount of energy transmitted to the load (negative direction) since device startup, Wh;73 -* Work energy regen –amount of regererated energy (positive direction) since device startup, Wh;74 -* Total energy+ –total energy received by the battery modules from the charger, Wh;75 -* Total energy- –total energy spent by the battery modules on the load, Wh;76 -* Total energy regen –total energy received by the battery modules during recuperation, Wh;68 +* Work charge+ - amount of charge received from charger (positive direction) since device startup, Ah; 69 +* Work charge- - amount of charge transmitted to the load (negative direction) since device startup, Ah; 70 +* Work energy+ - amount of energy received from charger (positive direction) since device startup, Wh; 71 +* Work energy- - amount of energy transmitted to the load (negative direction) since device startup, Wh; 72 +* Work energy regen - amount of regererated energy (positive direction) since device startup, Wh; 73 +* Total energy+ - total energy received by the battery modules from the charger, Wh; 74 +* Total energy- - total energy spent by the battery modules on the load, Wh; 75 +* Total energy regen - total energy received by the battery modules during recuperation, Wh; 77 77 * Total balanced energy – total energy dissipated by the battery modules on balancing resistors, Wh; 78 78 * Input signals – a bitfield including input signals (see [[Input signals>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInputsignals"]]); 79 79 * Internal signals – a bitfield including device internal signals (see [[Internal signals>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInternalsignals"]]);