Changes for page 4.2 Battery
Last modified by Admin on 2025/06/19 11:13
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -74,8 +74,55 @@ 74 74 * Total energy- - total energy spent by the battery modules on the load, Wh; 75 75 * Total energy regen - total energy received by the battery modules during recuperation, Wh; 76 76 * Total balanced energy – total energy dissipated by the battery modules on balancing resistors, Wh; 77 -* Input signals – a bitfield including input signals (see [[Input signals>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInputsignals"]]); 77 +* Input signals: 78 +** Battery cover – a signal from the battery cover; 79 +** Charger connected – a signal indicating that charger is connected; 80 +** Power up/down request – a request to power down the device; 81 +** Inhibit charging – a command to open the charging contactor; 82 +** Inhibit discharging – a command to open the discharging contactor; 83 +** CH contactor feedback – a signal from charging contactor feedback loop; 84 +** DCH contactor feedback – a signal from discharging contactor feedback loop; 85 +** Insulation status – a signal from an insulation monitoring device; 86 +** Charge request – a request to close the charging contactor; 87 +** Precharge request – a request to close the precharging contactor; 88 +** Discharge request – a request to close the discharging contactor; 89 +** PCH contactor feedback – a signal from precharging contactor feedback loop; 90 +** CH/DCH contactor feedback – a signal from charging/discharging contactor feedback loop; 91 +** Main contactor feedback – a signal from main contactor feedback loop; 92 +** Interlock – a signal from interlock loop; 93 +** Fuse 1, Fuse 2, Fuse 3 – signals from fuses; 94 +** Circuit breaker status – status of protection disconnector; 95 +** Balancing request – a request to balance the cells; 96 +** Close Main contactor – a request to close the main contactor; 97 +** Close External 1 – a request to active the External 1 signal; 78 78 * Internal signals – device internal signals: 99 +** Low SOC – a signal indicating the discharged battery; 100 +** High charging current; 101 +** Charging – state of the charging contactor; 102 +** Allow charging signal – signal allowing the operation of the charger; 103 +** Charging current present – charging current is detected; 104 +** Discharging – state of the discharging contactor; 105 +** Discharging current present – discharging current is detected; 106 +** Voltage is too high for charging; 107 +** Heater – signal to turn on heater; 108 +** Cooler – signal to turn on cooler; 109 +** Shutdown request (HYG/Spirit) – request to open the discharging contactor received from the HYG forklift; 110 +** Init – initialization of the device (calibration of the current sensor and searching BMS Logic devices); 111 +** Precharging – state of the precharging contactor; 112 +** Shutdown request (Combilift) – request to open the discharging contactor received from the Combilift forklift; 113 +** Cell analysis – operation of the algorithm for determining the discharge characteristics; 114 +** Balancing 1 – balancing the first series of cells; 115 +** Balancing 2 – balancing the second series of cells; 116 +** Discharging (AUX) – state of the discharging (AUX) contactor (powering of external equipment is on); 117 +** Power down ACK – signal to acknowledge powering down the battery system; 118 +** Crown EWS – signal sent to the Crown truck before opening the discharging contactor; 119 +** Main contactor – state of the main contactor; 120 +** Service reset; 121 +** Charging/Discharging – state of the charging/discharging contactor; 122 +** Ready to charge – the battery is ready to charge; 123 +** Ready to discharge – the battery is ready to discharge; 124 +** Power up – system power status; 125 +** External 1 – a signal controlled directly by external request; 79 79 * Errors 1 – errors of the battery 1: 80 80 ** Overcurrent; 81 81 ** Undervoltage;