Changes for page 4.2 Battery
Last modified by Admin on 2025/06/19 11:13
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -74,55 +74,8 @@ 74 74 * Total energy- - total energy spent by the battery modules on the load, Wh; 75 75 * Total energy regen - total energy received by the battery modules during recuperation, Wh; 76 76 * Total balanced energy – total energy dissipated by the battery modules on balancing resistors, Wh; 77 -* Input signals: 78 -** Battery cover – a signal from the battery cover; 79 -** Charger connected – a signal indicating that charger is connected; 80 -** Power up/down request – a request to power down the device; 81 -** Inhibit charging – a command to open the charging contactor; 82 -** Inhibit discharging – a command to open the discharging contactor; 83 -** CH contactor feedback – a signal from charging contactor feedback loop; 84 -** DCH contactor feedback – a signal from discharging contactor feedback loop; 85 -** Insulation status – a signal from an insulation monitoring device; 86 -** Charge request – a request to close the charging contactor; 87 -** Precharge request – a request to close the precharging contactor; 88 -** Discharge request – a request to close the discharging contactor; 89 -** PCH contactor feedback – a signal from precharging contactor feedback loop; 90 -** CH/DCH contactor feedback – a signal from charging/discharging contactor feedback loop; 91 -** Main contactor feedback – a signal from main contactor feedback loop; 92 -** Interlock – a signal from interlock loop; 93 -** Fuse 1, Fuse 2, Fuse 3 – signals from fuses; 94 -** Circuit breaker status – status of protection disconnector; 95 -** Balancing request – a request to balance the cells; 96 -** Close Main contactor – a request to close the main contactor; 97 -** Close External 1 – a request to active the External 1 signal; 77 +* Input signals – a bitfield including input signals (see [[Input signals>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInputsignals"]]); 98 98 * Internal signals – device internal signals: 99 -** Low SOC – a signal indicating the discharged battery; 100 -** High charging current; 101 -** Charging – state of the charging contactor; 102 -** Allow charging signal – signal allowing the operation of the charger; 103 -** Charging current present – charging current is detected; 104 -** Discharging – state of the discharging contactor; 105 -** Discharging current present – discharging current is detected; 106 -** Voltage is too high for charging; 107 -** Heater – signal to turn on heater; 108 -** Cooler – signal to turn on cooler; 109 -** Shutdown request (HYG/Spirit) – request to open the discharging contactor received from the HYG forklift; 110 -** Init – initialization of the device (calibration of the current sensor and searching BMS Logic devices); 111 -** Precharging – state of the precharging contactor; 112 -** Shutdown request (Combilift) – request to open the discharging contactor received from the Combilift forklift; 113 -** Cell analysis – operation of the algorithm for determining the discharge characteristics; 114 -** Balancing 1 – balancing the first series of cells; 115 -** Balancing 2 – balancing the second series of cells; 116 -** Discharging (AUX) – state of the discharging (AUX) contactor (powering of external equipment is on); 117 -** Power down ACK – signal to acknowledge powering down the battery system; 118 -** Crown EWS – signal sent to the Crown truck before opening the discharging contactor; 119 -** Main contactor – state of the main contactor; 120 -** Service reset; 121 -** Charging/Discharging – state of the charging/discharging contactor; 122 -** Ready to charge – the battery is ready to charge; 123 -** Ready to discharge – the battery is ready to discharge; 124 -** Power up – system power status; 125 -** External 1 – 126 126 * Errors 1 – errors of the battery 1: 127 127 ** Overcurrent; 128 128 ** Undervoltage; ... ... @@ -138,6 +138,7 @@ 138 138 ** Crown error – connection with a Crown forklift is lost; 139 139 ** Cell count error – number of cells does not match the specified value; 140 140 ** HYG offline – connection with a HYG forklift is lost; 94 +** Need acknowledge – there is an unacknowledged error in Error journal; 141 141 ** Combilift offline – connection with a Combilift forklift is lost; 142 142 ** Short circuit; 143 143 ** High contactor temperature; ... ... @@ -167,4 +167,5 @@ 167 167 ** Power switch error – short circuit in contactor coil control circuit or power switch overheating; 168 168 ** HVIL error – breakage of high-voltage interlock current loop; 169 169 ** Precharge error – capacitive load pre-charge process did not end during the estimated time; 170 -** Power fault – external devices power supply error: current sensors, HVIL, BMS Logic or CAN2 (int) bus powered devices. 124 +** Power fault – external devices power supply error: current sensors, HVIL, BMS Logic or CAN2 (int) bus powered devices; 125 +** Current limit error – charging or discharging current is more than limit calculated by Charge map or Discharge map.