Changes for page 4.2 Battery
Last modified by Admin on 2025/06/19 11:13
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -122,7 +122,7 @@ 122 122 ** Ready to charge – the battery is ready to charge; 123 123 ** Ready to discharge – the battery is ready to discharge; 124 124 ** Power up – system power status; 125 -** External 1 – 125 +** External 1 – a signal controlled directly by external request; 126 126 * Errors 1 – errors of the battery 1: 127 127 ** Overcurrent; 128 128 ** Undervoltage; ... ... @@ -138,6 +138,7 @@ 138 138 ** Crown error – connection with a Crown forklift is lost; 139 139 ** Cell count error – number of cells does not match the specified value; 140 140 ** HYG offline – connection with a HYG forklift is lost; 141 +** Need acknowledge – there is an unacknowledged error in Error journal; 141 141 ** Combilift offline – connection with a Combilift forklift is lost; 142 142 ** Short circuit; 143 143 ** High contactor temperature; ... ... @@ -167,4 +167,5 @@ 167 167 ** Power switch error – short circuit in contactor coil control circuit or power switch overheating; 168 168 ** HVIL error – breakage of high-voltage interlock current loop; 169 169 ** Precharge error – capacitive load pre-charge process did not end during the estimated time; 170 -** Power fault – external devices power supply error: current sensors, HVIL, BMS Logic or CAN2 (int) bus powered devices. 171 +** Power fault – external devices power supply error: current sensors, HVIL, BMS Logic or CAN2 (int) bus powered devices; 172 +** Current limit error – charging or discharging current is more than limit calculated by Charge map or Discharge map.