Changes for page 4.2 Battery

Last modified by Admin on 2025/06/19 11:13

From version 6.9
edited by Admin
on 2024/12/26 16:10
Change comment: There is no comment for this version
To version 7.1
edited by Admin
on 2024/12/26 16:13
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -122,7 +122,7 @@
122 122  ** Ready to charge – the battery is ready to charge;
123 123  ** Ready to discharge – the battery is ready to discharge;
124 124  ** Power up – system power status;
125 -** External 1 –
125 +** External 1 – a signal controlled directly by external request;
126 126  * Errors 1 – errors of the battery 1:
127 127  ** Overcurrent;
128 128  ** Undervoltage;
... ... @@ -138,6 +138,7 @@
138 138  ** Crown error – connection with a Crown forklift is lost;
139 139  ** Cell count error – number of cells does not match the specified value;
140 140  ** HYG offline – connection with a HYG forklift is lost;
141 +** Need acknowledge – there is an unacknowledged error in Error journal;
141 141  ** Combilift offline – connection with a Combilift forklift is lost;
142 142  ** Short circuit;
143 143  ** High contactor temperature;
... ... @@ -167,4 +167,5 @@
167 167  ** Power switch error – short circuit in contactor coil control circuit or power switch overheating;
168 168  ** HVIL error – breakage of high-voltage interlock current loop;
169 169  ** Precharge error – capacitive load pre-charge process did not end during the estimated time;
170 -** Power fault – external devices power supply error: current sensors, HVIL, BMS Logic or CAN2 (int) bus powered devices.
171 +** Power fault – external devices power supply error: current sensors, HVIL, BMS Logic or CAN2 (int) bus powered devices;
172 +** Current limit error – charging or discharging current is more than limit calculated by Charge map or Discharge map.