69 69  * Work charge- - amount of charge transmitted to the load (negative direction) since device startup, Ah;
70 70  * Work energy+ - amount of energy received from charger (positive direction) since device startup, Wh;
71 71  * Work energy- - amount of energy transmitted to the load (negative direction) since device startup, Wh;
72 -* Work energy regen - amount of regererated energy (positive direction) since device startup, Wh;
73 -* Total energy+ - total energy received by the battery modules from the charger, Wh;
72 +* Work energy- - amount of energy transmitted to the load (negative direction) since device startup, Wh;
73 +* Total energy+ - total energy received by the battery modules from the charger and during recuperation, Wh;
74 74  * Total energy- - total energy spent by the battery modules on the load, Wh;
75 -* Total energy regen - total energy received by the battery modules during recuperation, Wh;
76 76  * Total balanced energy – total energy dissipated by the battery modules on balancing resistors, Wh;
77 -* Input signals:
76 +* Input singals:
78 78  ** Battery cover – a signal from the battery cover;
79 79  ** Charger connected – a signal indicating that charger is connected;
80 80  ** Power up/down request – a request to power down the device;
... ... @@ -93,8 +93,7 @@
93 93  ** Fuse 1, Fuse 2, Fuse 3 – signals from fuses;
94 94  ** Circuit breaker status – status of protection disconnector;
95 95  ** Balancing request – a request to balance the cells;
96 -** Close Main contactor – a request to close the main contactor;
97 -** Close External 1 – a request to active the External 1 signal;
95 +** Close Main contactor – a request to close the main contactor.
98 98  * Internal signals – device internal signals:
99 99  ** Low SOC – a signal indicating the discharged battery;
100 100  ** High charging current;
... ... @@ -122,7 +122,6 @@
122 122  ** Ready to charge – the battery is ready to charge;
123 123  ** Ready to discharge – the battery is ready to discharge;
124 124  ** Power up – system power status;
125 -** Extern
126 126  * Errors 1 – errors of the battery 1:
127 127  ** Overcurrent;
128 128  ** Undervoltage;