Changes for page 4.2 Battery
Last modified by Admin on 2025/06/19 11:13
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -70,99 +70,11 @@ 70 70 * Work energy+ - amount of energy received from charger (positive direction) since device startup, Wh; 71 71 * Work energy- - amount of energy transmitted to the load (negative direction) since device startup, Wh; 72 72 * Work energy regen - amount of regererated energy (positive direction) since device startup, Wh; 73 -* Total energy+ - total energy received by the battery modules from the charger and during recuperation, Wh;73 +* Total energy+ - total energy received by the battery modules from the charger, Wh; 74 74 * Total energy- - total energy spent by the battery modules on the load, Wh; 75 -* Total energy regen - total energy received by the battery modules from the charger andduring recuperation, Wh;75 +* Total energy regen - total energy received by the battery modules during recuperation, Wh; 76 76 * Total balanced energy – total energy dissipated by the battery modules on balancing resistors, Wh; 77 -* Input singals: 78 -** Battery cover – a signal from the battery cover; 79 -** Charger connected – a signal indicating that charger is connected; 80 -** Power up/down request – a request to power down the device; 81 -** Inhibit charging – a command to open the charging contactor; 82 -** Inhibit discharging – a command to open the discharging contactor; 83 -** CH contactor feedback – a signal from charging contactor feedback loop; 84 -** DCH contactor feedback – a signal from discharging contactor feedback loop; 85 -** Insulation status – a signal from an insulation monitoring device; 86 -** Charge request – a request to close the charging contactor; 87 -** Precharge request – a request to close the precharging contactor; 88 -** Discharge request – a request to close the discharging contactor; 89 -** PCH contactor feedback – a signal from precharging contactor feedback loop; 90 -** CH/DCH contactor feedback – a signal from charging/discharging contactor feedback loop; 91 -** Main contactor feedback – a signal from main contactor feedback loop; 92 -** Interlock – a signal from interlock loop; 93 -** Fuse 1, Fuse 2, Fuse 3 – signals from fuses; 94 -** Circuit breaker status – status of protection disconnector; 95 -** Balancing request – a request to balance the cells; 96 -** Close Main contactor – a request to close the main contactor. 97 -* Internal signals – device internal signals: 98 -** Low SOC – a signal indicating the discharged battery; 99 -** High charging current; 100 -** Charging – state of the charging contactor; 101 -** Allow charging signal – signal allowing the operation of the charger; 102 -** Charging current present – charging current is detected; 103 -** Discharging – state of the discharging contactor; 104 -** Discharging current present – discharging current is detected; 105 -** Voltage is too high for charging; 106 -** Heater – signal to turn on heater; 107 -** Cooler – signal to turn on cooler; 108 -** Shutdown request (HYG/Spirit) – request to open the discharging contactor received from the HYG forklift; 109 -** Init – initialization of the device (calibration of the current sensor and searching BMS Logic devices); 110 -** Precharging – state of the precharging contactor; 111 -** Shutdown request (Combilift) – request to open the discharging contactor received from the Combilift forklift; 112 -** Cell analysis – operation of the algorithm for determining the discharge characteristics; 113 -** Balancing 1 – balancing the first series of cells; 114 -** Balancing 2 – balancing the second series of cells; 115 -** Discharging (AUX) – state of the discharging (AUX) contactor (powering of external equipment is on); 116 -** Power down ACK – signal to acknowledge powering down the battery system; 117 -** Crown EWS – signal sent to the Crown truck before opening the discharging contactor; 118 -** Main contactor – state of the main contactor; 119 -** Service reset; 120 -** Charging/Discharging – state of the charging/discharging contactor; 121 -** Ready to charge – the battery is ready to charge; 122 -** Ready to discharge – the battery is ready to discharge; 123 -** Power up – system power status; 77 +* Input signals – a bitfield including input signals (see [[Input signals>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInputsignals"]]); 78 +* Internal signals – a bitfield including device internal signals (see [[Internal signals>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInternalsignals"]]); 124 124 * Errors 1 – errors of the battery 1: 125 -** Overcurrent; 126 -** Undervoltage; 127 -** Overvoltage; 128 -** Low temperature (DCH) – temperature is too low for discharging; 129 -** High temperature (DCH) – temperature is too high for discharging; 130 -** Battery cover error – battery cover is open; 131 -** High humidity – humidity of the battery is increased; 132 -** Water – there is water in the battery enclosure; 133 -** High Logic temperature – at least one of the Logic devices is overheated; 134 -** Logic offline – at least one of the Logic devices is offline; 135 -** Critical error; 136 -** Crown error – connection with a Crown forklift is lost; 137 -** Cell count error – number of cells does not match the specified value; 138 -** HYG offline – connection with a HYG forklift is lost; 139 -** Combilift offline – connection with a Combilift forklift is lost; 140 -** Short circuit; 141 -** High contactor temperature; 142 -** ADC error – current cannot be measured; 143 -** Current sensor error – error in the current sensor circuit; 144 -** CH contactor cycles error – switching frequency of the charging contactor is too high; 145 -** DCH contactor cycles error – switching frequency of the discharging contactor is too high; 146 -** Shunt offline – connection with the shunt current sensor is lost; 147 -** Shunt error – internal error of the shunt current sensor; 148 -** WDT reset – watchdog timer reset the device; 149 -** No temperature sensors – the device has no temperature sensors connected; 150 -** Temperature sensor is shorted – some temperature sensors are shorted; 151 -** Spirit offline – connection with a Spirit forklift is lost; 152 152 * Errors 2 – errors of the battery 2: 153 -** Low temperature (CH) – temperature is too low for charging; 154 -** High temperature (CH) – temperature is too high for charging; 155 -** Unallowable charging – charging the battery through the discharging contactor; 156 -** Stuck contactor; 157 -** CH contactor feedback error – the control signals for the charging contactor and the contactor feedback differ; 158 -** DCH contactor feedback error – the control signals for the discharging contactor and the contactor feedback differ; 159 -** Insulation fault; 160 -** PCH contactor feedback error – the control signals for the precharging contactor and the contactor feedback differ; 161 -** CH/DCH contactor feedback error – the control signals for the charging/discharging contactor and the contactor feedback differ; 162 -** Main contactor feedback error – the control signals for the main contactor and the contactor feedback differ; 163 -** General error; 164 -** High voltage fault – failure of high voltage measuring circuits; 165 -** Power switch error – short circuit in contactor coil control circuit or power switch overheating; 166 -** HVIL error – breakage of high-voltage interlock current loop; 167 -** Precharge error – capacitive load pre-charge process did not end during the estimated time; 168 -** Power fault – external devices power supply error: current sensors, HVIL, BMS Logic or CAN2 (int) bus powered devices.