Changes for page 4.2 Battery

Last modified by Admin on 2025/06/19 11:13

From version 6.6
edited by Admin
on 2024/12/26 16:07
Change comment: There is no comment for this version
To version 6.3
edited by Admin
on 2024/12/26 16:04
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -21,9 +21,9 @@
21 21  * Number of Logic devices – number of connected Logic devices;
22 22  * Logic command rate – number of commands transmitted to Logic devices, com/s;
23 23  * Minimum Logic temperature – minimum temperature among Logic devices, °C;
24 -* Min. Logic temp.: Logic index – number of Logic with minimum temperature;
24 +* # of Logic with minimum temperature – number of Logic with minimum temperature;
25 25  * Maximum Logic temperature – minimum temperature among Logic devices, °C;
26 -* Max. Logic temp.: Logic index – number of Logic with maximum temperature;
26 +* # of Logic with maximum temperature – number of Logic with maximum temperature;
27 27  * Number of cells – number of connected cells;
28 28  * Average cell temperature, °C;
29 29  * Minimum cell temperature, °C;
... ... @@ -33,17 +33,17 @@
33 33  * Max. cell temp.: Logic index  – number of Logic with maximum cell temperature;
34 34  * Max. cell temp.: cell index – number of cell with maximum temperature;
35 35  * Minimum cell voltage, V;
36 -* Min. cell volt.: Logic index – number of Logic with minimum voltage;
37 -* Min. cell volt.: cell index – number of cell with minimum voltage;
36 +* Max. cell temp.: Logic index – number of Logic with minimum voltage;
37 +* # of cell with minimum voltage – number of cell with minimum voltage;
38 38  * Maximum cell voltage, V;
39 -* Max. cell volt.: Logic index – number of Logic with maximum voltage;
40 -* Max. cell volt.: cell index – number of cell with maximum voltage;
39 +* # of Logic with maximum cell voltage – number of Logic with maximum voltage;
40 +* # of cell with maximum voltage – number of cell with maximum voltage;
41 41  * Minimum cell SOC, %;
42 -* Min. cell SOC: Logic index – number of Logic with minimum SOC;
43 -* Min. cell SOC: cell index – number of cell with minimum SOC;
42 +* # of Logic with minimum cell SOC – number of Logic with minimum SOC;
43 +* # of cell with minimum SOC – number of cell with minimum SOC;
44 44  * Maximum cell SOC, %;
45 -* Max. cell SOC: Logic index – number of Logic with maximum SOC;
46 -* Max. cell SOC: cell index – number of cell with maximum SOC;
45 +* # of Logic with maximum cell SOC – number of Logic with maximum SOC;
46 +* # of cell with maximum SOC – number of cell with maximum SOC;
47 47  * Number of balancing cells;
48 48  * State:
49 49  ** Discharging ON;
... ... @@ -69,10 +69,8 @@
69 69  * Work charge- - amount of charge transmitted to the load (negative direction) since device startup, Ah;
70 70  * Work energy+ - amount of energy received from charger (positive direction) since device startup, Wh;
71 71  * Work energy- - amount of energy transmitted to the load (negative direction) since device startup, Wh;
72 -* Work energy regen - amount of regererated energy (positive direction) since device startup, Wh;
73 73  * Total energy+ - total energy received by the battery modules from the charger and during recuperation, Wh;
74 74  * Total energy- - total energy spent by the battery modules on the load, Wh;
75 -* Total energy regen - total energy received by the battery modules from the charger and during recuperation, Wh;
76 76  * Total balanced energy – total energy dissipated by the battery modules on balancing resistors, Wh;
77 77  * Input singals:
78 78  ** Battery cover – a signal from the battery cover;