... ... @@ -4,27 +4,28 @@
4 4  (% data-numbered-headings-start="2" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
5 5  == Battery ==
6 6  
7 -Battery parameters are summarized in the "Battery" section:
7 +Параметры батареи сведены в раздел «Battery»:
8 8  
9 9  [[image:1735228916836-719.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="370" width="800"]]
10 10  
11 -In this section:
11 +В этом разделе:
12 12  
13 -* Voltage – voltage of the battery, V;
14 -* Current – current of the battery, A;
15 -* Internal resistance – internal resistance of the battery, Ohm;
16 -* Main voltage – supply voltage on the BMS, V;
17 -* Power switch voltage – supply voltage on the power switches, V;
18 -* Board temperature – internal temperature of the BMS, °C;
19 -* Board humidity – relative humidity measured by the BMS, %;
20 -* Temperature 1, 2 – temperature measured by the external temperature sensors, °C;
21 -* Number of Logic devices – number of connected Logic devices;
22 -* Logic command rate – number of commands transmitted to Logic devices, com/s;
23 -* Minimum Logic temperature – minimum temperature among Logic devices, °C;
24 -* Min. Logic temp.: Logic index – number of Logic with minimum temperature;
25 -* Maximum Logic temperature – minimum temperature among Logic devices, °C;
26 -* Max. Logic temp.: Logic index – number of Logic with maximum temperature;
27 -* Number of cells – number of connected cells;
13 +* Voltage – напряжение батареи, В;
14 +* Current – ток батареи, А;
15 +* Internal resistance – сопротивление батареи, Ом;
16 +* Main voltage – напряжение питания устройства, В;
17 +* Power switch voltage – напряжение питания силовых ключей, В;
18 +* Board temperature – температура устройства, °C;
19 +* Board humidity – влажность измеренная внутренним датчиком устройства, °C;
20 +* Temperature 1, 2 – температура, измеренная внешним датчиком, °C;
21 +* Number of Logic devices – количество подключенных устройств BMS Logic;
22 +* Logic command rate – скорость обмена с устройствами BMS Logic, ком./с;
23 +* Minimum Logic temperature – минимальная температура среди устройств BMS Logic, °C;
24 +* Min. Logic temp.: Logic index – номер устройства Logic, имеющего минимальную температуру;
25 +* Maximum Logic temperature – максимальная температура среди устройств BMS Logic, °C;
26 +* Max. Logic temp.: Logic index – номер устройства Logic, имеющего максимальную температуру;
27 +* Number of cells –
28 +* количество подключенных ячеек;
28 28  * Average cell temperature, °C;
29 29  * Minimum cell temperature, °C;
30 30  * Min. cell temp.: Logic index – number of Logic with minimum cell temperature;
... ... @@ -65,103 +65,15 @@
65 65  * Discharge current limit – maximum allowed discharge current of the battery, A;
66 66  * High voltage 1 – voltage before the contactors, V;
67 67  * High voltage 2 – voltage after the contactors, V;
68 -* Work charge+ - amount of charge received from charger (positive direction) since device startup, Ah;
69 -* Work charge- - amount of charge transmitted to the load (negative direction) since device startup, Ah;
70 -* Work energy+ - amount of energy received from charger (positive direction) since device startup, Wh;
71 -* Work energy- - amount of energy transmitted to the load (negative direction) since device startup, Wh;
72 -* Work energy- - amount of energy transmitted to the load (negative direction) since device startup, Wh;
73 -* Total energy+ - total energy received by the battery modules from the charger and during recuperation, Wh;
74 -* Total energy- - total energy spent by the battery modules on the load, Wh;
69 +* Work charge+ – amount of charge received from charger (positive direction) since device startup, Ah;
70 +* Work charge- – amount of charge transmitted to the load (negative direction) since device startup, Ah;
71 +* Work energy+ – amount of energy received from charger (positive direction) since device startup, Wh;
72 +* Work energy- – amount of energy transmitted to the load (negative direction) since device startup, Wh;
73 +* Work energy regen – amount of regererated energy (positive direction) since device startup, Wh;
74 +* Total energy+ – total energy received by the battery modules from the charger, Wh;
75 +* Total energy- – total energy spent by the battery modules on the load, Wh;
76 +* Total energy regen – total energy received by the battery modules during recuperation, Wh;
75 75  * Total balanced energy – total energy dissipated by the battery modules on balancing resistors, Wh;
76 -* Input singals:
77 -** Battery cover – a signal from the battery cover;
78 -** Charger connected – a signal indicating that charger is connected;
79 -** Power up/down request – a request to power down the device;
80 -** Inhibit charging – a command to open the charging contactor;
81 -** Inhibit discharging – a command to open the discharging contactor;
82 -** CH contactor feedback – a signal from charging contactor feedback loop;
83 -** DCH contactor feedback – a signal from discharging contactor feedback loop;
84 -** Insulation status – a signal from an insulation monitoring device;
85 -** Charge request – a request to close the charging contactor;
86 -** Precharge request – a request to close the precharging contactor;
87 -** Discharge request – a request to close the discharging contactor;
88 -** PCH contactor feedback – a signal from precharging contactor feedback loop;
89 -** CH/DCH contactor feedback – a signal from charging/discharging contactor feedback loop;
90 -** Main contactor feedback – a signal from main contactor feedback loop;
91 -** Interlock – a signal from interlock loop;
92 -** Fuse 1, Fuse 2, Fuse 3 – signals from fuses;
93 -** Circuit breaker status – status of protection disconnector;
94 -** Balancing request – a request to balance the cells;
95 -** Close Main contactor – a request to close the main contactor.
96 -* Internal signals – device internal signals:
97 -** Low SOC – a signal indicating the discharged battery;
98 -** High charging current;
99 -** Charging – state of the charging contactor;
100 -** Allow charging signal – signal allowing the operation of the charger;
101 -** Charging current present – charging current is detected;
102 -** Discharging – state of the discharging contactor;
103 -** Discharging current present – discharging current is detected;
104 -** Voltage is too high for charging;
105 -** Heater – signal to turn on heater;
106 -** Cooler – signal to turn on cooler;
107 -** Shutdown request (HYG/Spirit) – request to open the discharging contactor received from the HYG forklift;
108 -** Init – initialization of the device (calibration of the current sensor and searching BMS Logic devices);
109 -** Precharging – state of the precharging contactor;
110 -** Shutdown request (Combilift) – request to open the discharging contactor received from the Combilift forklift;
111 -** Cell analysis – operation of the algorithm for determining the discharge characteristics;
112 -** Balancing 1 – balancing the first series of cells;
113 -** Balancing 2 – balancing the second series of cells;
114 -** Discharging (AUX) – state of the discharging (AUX) contactor (powering of external equipment is on);
115 -** Power down ACK – signal to acknowledge powering down the battery system;
116 -** Crown EWS – signal sent to the Crown truck before opening the discharging contactor;
117 -** Main contactor – state of the main contactor;
118 -** Service reset;
119 -** Charging/Discharging – state of the charging/discharging contactor;
120 -** Ready to charge – the battery is ready to charge;
121 -** Ready to discharge – the battery is ready to discharge;
122 -** Power up – system power status;
123 -* Errors 1 – errors of the battery 1:
124 -** Overcurrent;
125 -** Undervoltage;
126 -** Overvoltage;
127 -** Low temperature (DCH) – temperature is too low for discharging;
128 -** High temperature (DCH) – temperature is too high for discharging;
129 -** Battery cover error – battery cover is open;
130 -** High humidity – humidity of the battery is increased;
131 -** Water – there is water in the battery enclosure;
132 -** High Logic temperature – at least one of the Logic devices is overheated;
133 -** Logic offline – at least one of the Logic devices is offline;
134 -** Critical error;
135 -** Crown error – connection with a Crown forklift is lost;
136 -** Cell count error – number of cells does not match the specified value;
137 -** HYG offline – connection with a HYG forklift is lost;
138 -** Combilift offline – connection with a Combilift forklift is lost;
139 -** Short circuit;
140 -** High contactor temperature;
141 -** ADC error – current cannot be measured;
142 -** Current sensor error – error in the current sensor circuit;
143 -** CH contactor cycles error – switching frequency of the charging contactor is too high;
144 -** DCH contactor cycles error – switching frequency of the discharging contactor is too high;
145 -** Shunt offline – connection with the shunt current sensor is lost;
146 -** Shunt error – internal error of the shunt current sensor;
147 -** WDT reset – watchdog timer reset the device;
148 -** No temperature sensors – the device has no temperature sensors connected;
149 -** Temperature sensor is shorted – some temperature sensors are shorted;
150 -** Spirit offline – connection with a Spirit forklift is lost;
151 -* Errors 2 – errors of the battery 2:
152 -** Low temperature (CH) – temperature is too low for charging;
153 -** High temperature (CH) – temperature is too high for charging;
154 -** Unallowable charging – charging the battery through the discharging contactor;
155 -** Stuck contactor;
156 -** CH contactor feedback error – the control signals for the charging contactor and the contactor feedback differ;
157 -** DCH contactor feedback error – the control signals for the discharging contactor and the contactor feedback differ;
158 -** Insulation fault;
159 -** PCH contactor feedback error – the control signals for the precharging contactor and the contactor feedback differ;
160 -** CH/DCH contactor feedback error – the control signals for the charging/discharging contactor and the contactor feedback differ;
161 -** Main contactor feedback error – the control signals for the main contactor and the contactor feedback differ;
162 -** General error;
163 -** High voltage fault – failure of high voltage measuring circuits;
164 -** Power switch error – short circuit in contactor coil control circuit or power switch overheating;
165 -** HVIL error – breakage of high-voltage interlock current loop;
166 -** Precharge error – capacitive load pre-charge process did not end during the estimated time;
167 -** Power fault – external devices power supply error: current sensors, HVIL, BMS Logic or CAN2 (int) bus powered devices.
78 +* Input signals – a bitfield including input signals (see [[Input signals>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInputsignals"]]);
79 +* Internal signals – a bitfield including device internal signals (see [[Internal signals>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInternalsignals"]]);
80 +* Errors 1, 2 – errors of the battery (see see [[Errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HErrors"]]).