Changes for page 4.2 Battery
Last modified by Admin on 2025/06/19 11:13
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -21,9 +21,9 @@ 21 21 * Number of Logic devices – number of connected Logic devices; 22 22 * Logic command rate – number of commands transmitted to Logic devices, com/s; 23 23 * Minimum Logic temperature – minimum temperature among Logic devices, °C; 24 -* #ofLogicwithminimumtemperature– number of Logic with minimum temperature;24 +* Min. Logic temp.: Logic index – number of Logic with minimum temperature; 25 25 * Maximum Logic temperature – minimum temperature among Logic devices, °C; 26 -* #ofLogicwithmaximumtemperature– number of Logic with maximum temperature;26 +* Max. Logic temp.: Logic index – number of Logic with maximum temperature; 27 27 * Number of cells – number of connected cells; 28 28 * Average cell temperature, °C; 29 29 * Minimum cell temperature, °C; ... ... @@ -40,7 +40,7 @@ 40 40 * Max. cell volt.: cell index – number of cell with maximum voltage; 41 41 * Minimum cell SOC, %; 42 42 * Min. cell SOC: Logic index – number of Logic with minimum SOC; 43 -* M ax. cell SOC: cell index – number of cell with minimum SOC;43 +* Min. cell SOC: cell index – number of cell with minimum SOC; 44 44 * Maximum cell SOC, %; 45 45 * Max. cell SOC: Logic index – number of Logic with maximum SOC; 46 46 * Max. cell SOC: cell index – number of cell with maximum SOC; ... ... @@ -69,10 +69,12 @@ 69 69 * Work charge- - amount of charge transmitted to the load (negative direction) since device startup, Ah; 70 70 * Work energy+ - amount of energy received from charger (positive direction) since device startup, Wh; 71 71 * Work energy- - amount of energy transmitted to the load (negative direction) since device startup, Wh; 72 -* Total energy+ - total energy received by the battery modules from the charger and during recuperation, Wh; 72 +* Work energy regen - amount of regererated energy (positive direction) since device startup, Wh; 73 +* Total energy+ - total energy received by the battery modules from the charger, Wh; 73 73 * Total energy- - total energy spent by the battery modules on the load, Wh; 75 +* Total energy regen - total energy received by the battery modules during recuperation, Wh; 74 74 * Total balanced energy – total energy dissipated by the battery modules on balancing resistors, Wh; 75 -* Input si ngals:77 +* Input signals: 76 76 ** Battery cover – a signal from the battery cover; 77 77 ** Charger connected – a signal indicating that charger is connected; 78 78 ** Power up/down request – a request to power down the device; ... ... @@ -91,7 +91,8 @@ 91 91 ** Fuse 1, Fuse 2, Fuse 3 – signals from fuses; 92 92 ** Circuit breaker status – status of protection disconnector; 93 93 ** Balancing request – a request to balance the cells; 94 -** Close Main contactor – a request to close the main contactor. 96 +** Close Main contactor – a request to close the main contactor; 97 +** Close External 1 – a request to active the External 1 signal; 95 95 * Internal signals – device internal signals: 96 96 ** Low SOC – a signal indicating the discharged battery; 97 97 ** High charging current; ... ... @@ -119,6 +119,7 @@ 119 119 ** Ready to charge – the battery is ready to charge; 120 120 ** Ready to discharge – the battery is ready to discharge; 121 121 ** Power up – system power status; 125 +** Extern 122 122 * Errors 1 – errors of the battery 1: 123 123 ** Overcurrent; 124 124 ** Undervoltage;