Changes for page 4.2 Battery

Last modified by Admin on 2025/06/19 11:13

From version 6.2
edited by Admin
on 2024/12/26 16:03
Change comment: There is no comment for this version
To version 4.3
edited by Admin
on 2024/12/11 11:33
Change comment: Update document after refactoring.

Summary

Details

Page properties
Content
... ... @@ -6,7 +6,7 @@
6 6  
7 7  Battery parameters are summarized in the "Battery" section:
8 8  
9 -[[image:1735228916836-719.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="370" width="800"]]
9 +[[image:1733403002027-572.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="507" width="800"]]
10 10  
11 11  In this section:
12 12  
... ... @@ -27,7 +27,7 @@
27 27  * Number of cells – number of connected cells;
28 28  * Average cell temperature, °C;
29 29  * Minimum cell temperature, °C;
30 -* Min cell temperature – number of Logic with minimum cell temperature;
30 +* # of Logic with minimum cell temperature – number of Logic with minimum cell temperature;
31 31  * # of cell with minimum temperature – number of cell with minimum temperature;
32 32  * Maximum cell temperature, °C;
33 33  * # of Logic with maximum cell temperature – number of Logic with maximum cell temperature;
... ... @@ -72,26 +72,6 @@
72 72  * Total energy+ - total energy received by the battery modules from the charger and during recuperation, Wh;
73 73  * Total energy- - total energy spent by the battery modules on the load, Wh;
74 74  * Total balanced energy – total energy dissipated by the battery modules on balancing resistors, Wh;
75 -* Input singals:
76 -** Battery cover – a signal from the battery cover;
77 -** Charger connected – a signal indicating that charger is connected;
78 -** Power up/down request – a request to power down the device;
79 -** Inhibit charging – a command to open the charging contactor;
80 -** Inhibit discharging – a command to open the discharging contactor;
81 -** CH contactor feedback – a signal from charging contactor feedback loop;
82 -** DCH contactor feedback – a signal from discharging contactor feedback loop;
83 -** Insulation status – a signal from an insulation monitoring device;
84 -** Charge request – a request to close the charging contactor;
85 -** Precharge request – a request to close the precharging contactor;
86 -** Discharge request – a request to close the discharging contactor;
87 -** PCH contactor feedback – a signal from precharging contactor feedback loop;
88 -** CH/DCH contactor feedback – a signal from charging/discharging contactor feedback loop;
89 -** Main contactor feedback – a signal from main contactor feedback loop;
90 -** Interlock – a signal from interlock loop;
91 -** Fuse 1, Fuse 2, Fuse 3 – signals from fuses;
92 -** Circuit breaker status – status of protection disconnector;
93 -** Balancing request – a request to balance the cells;
94 -** Close Main contactor – a request to close the main contactor.
95 95  * Internal signals – device internal signals:
96 96  ** Low SOC – a signal indicating the discharged battery;
97 97  ** High charging current;
1735228916836-719.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -116.6 KB
Content