... ... @@ -21,9 +21,9 @@
21 21  * Number of Logic devices – number of connected Logic devices;
22 22  * Logic command rate – number of commands transmitted to Logic devices, com/s;
23 23  * Minimum Logic temperature – minimum temperature among Logic devices, °C;
24 -* Min. Logic temp.: Logic index – number of Logic with minimum temperature;
24 +* # of Logic with minimum temperature – number of Logic with minimum temperature;
25 25  * Maximum Logic temperature – minimum temperature among Logic devices, °C;
26 -* Max. Logic temp.: Logic index – number of Logic with maximum temperature;
26 +* # of Logic with maximum temperature – number of Logic with maximum temperature;
27 27  * Number of cells – number of connected cells;
28 28  * Average cell temperature, °C;
29 29  * Minimum cell temperature, °C;
... ... @@ -40,7 +40,7 @@
40 40  * Max. cell volt.: cell index – number of cell with maximum voltage;
41 41  * Minimum cell SOC, %;
42 42  * Min. cell SOC: Logic index – number of Logic with minimum SOC;
43 -* Min. cell SOC: cell index – number of cell with minimum SOC;
43 +* Max. cell SOC: cell index – number of cell with minimum SOC;
44 44  * Maximum cell SOC, %;
45 45  * Max. cell SOC: Logic index – number of Logic with maximum SOC;
46 46  * Max. cell SOC: cell index – number of cell with maximum SOC;
... ... @@ -69,12 +69,10 @@
69 69  * Work charge- - amount of charge transmitted to the load (negative direction) since device startup, Ah;
70 70  * Work energy+ - amount of energy received from charger (positive direction) since device startup, Wh;
71 71  * Work energy- - amount of energy transmitted to the load (negative direction) since device startup, Wh;
72 -* Work energy regen - amount of regererated energy (positive direction) since device startup, Wh;
73 -* Total energy+ - total energy received by the battery modules from the charger, Wh;
72 +* Total energy+ - total energy received by the battery modules from the charger and during recuperation, Wh;
74 74  * Total energy- - total energy spent by the battery modules on the load, Wh;
75 -* Total energy regen - total energy received by the battery modules during recuperation, Wh;
76 76  * Total balanced energy – total energy dissipated by the battery modules on balancing resistors, Wh;
77 -* Input signals:
75 +* Input singals:
78 78  ** Battery cover – a signal from the battery cover;
79 79  ** Charger connected – a signal indicating that charger is connected;
80 80  ** Power up/down request – a request to power down the device;
... ... @@ -93,8 +93,7 @@
93 93  ** Fuse 1, Fuse 2, Fuse 3 – signals from fuses;
94 94  ** Circuit breaker status – status of protection disconnector;
95 95  ** Balancing request – a request to balance the cells;
96 -** Close Main contactor – a request to close the main contactor;
97 -** Close External 1 – a request to active the External 1 signal;
94 +** Close Main contactor – a request to close the main contactor.
98 98  * Internal signals – device internal signals:
99 99  ** Low SOC – a signal indicating the discharged battery;
100 100  ** High charging current;
... ... @@ -122,7 +122,6 @@
122 122  ** Ready to charge – the battery is ready to charge;
123 123  ** Ready to discharge – the battery is ready to discharge;
124 124  ** Power up – system power status;
125 -** External 1 – a signal controlled directly by external request;
126 126  * Errors 1 – errors of the battery 1:
127 127  ** Overcurrent;
128 128  ** Undervoltage;
... ... @@ -138,7 +138,6 @@
138 138  ** Crown error – connection with a Crown forklift is lost;
139 139  ** Cell count error – number of cells does not match the specified value;
140 140  ** HYG offline – connection with a HYG forklift is lost;
141 -** Need acknowledge – there is an unacknowledged
142 142  ** Combilift offline – connection with a Combilift forklift is lost;
143 143  ** Short circuit;