... ... @@ -6,11 +6,12 @@
6 6  
7 7  Battery parameters are summarized in the "Battery" section:
8 8  
9 -[[image:1733403002027-572.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="507" width="800"]]
9 +[[image:1750331506968-446.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="562" width="800"]]
10 10  
11 11  In this section:
12 12  
13 -* Voltage – voltage of the battery, V;
13 +* Voltage (sum of cell voltages) – voltage of the battery, defined as sum of all cell voltages, V;
14 +* Voltage – voltage of the battery, measured before contactors, V;
14 14  * Current – current of the battery, A;
15 15  * Internal resistance – internal resistance of the battery, Ohm;
16 16  * Main voltage – supply voltage on the BMS, V;
... ... @@ -20,30 +20,32 @@
20 20  * Temperature 1, 2 – temperature measured by the external temperature sensors, °C;
21 21  * Number of Logic devices – number of connected Logic devices;
22 22  * Logic command rate – number of commands transmitted to Logic devices, com/s;
24 +* Logic retry attempts – amount of BMS Logic retry attempts;
23 23  * Minimum Logic temperature – minimum temperature among Logic devices, °C;
24 -* # of Logic with minimum temperature – number of Logic with minimum temperature;
26 +* Min. Logic temp.: Logic index – number of Logic with minimum temperature;
25 25  * Maximum Logic temperature – minimum temperature among Logic devices, °C;
26 -* # of Logic with maximum temperature – number of Logic with maximum temperature;
28 +* Max. Logic temp.: Logic index – number of Logic with maximum temperature;
27 27  * Number of cells – number of connected cells;
28 28  * Average cell temperature, °C;
29 29  * Minimum cell temperature, °C;
30 -* # of Logic with minimum cell temperature – number of Logic with minimum cell temperature;
31 -* # of cell with minimum temperature – number of cell with minimum temperature;
32 +* Min. cell temp.: Logic index – number of Logic with minimum cell temperature;
33 +* Min. cell temp.: cell index – number of cell with minimum temperature;
32 32  * Maximum cell temperature, °C;
33 -* # of Logic with maximum cell temperature – number of Logic with maximum cell temperature;
34 -* # of cell with maximum temperature – number of cell with maximum temperature;
35 +* Max. cell temp.: Logic index  – number of Logic with maximum cell temperature;
36 +* Max. cell temp.: cell index – number of cell with maximum temperature;
37 +* Average cell voltage, V;
35 35  * Minimum cell voltage, V;
36 -* # of Logic with minimum cell voltage – number of Logic with minimum voltage;
37 -* # of cell with minimum voltage – number of cell with minimum voltage;
39 +* Min. cell volt.: Logic index – number of Logic with minimum voltage;
40 +* Min. cell volt.: cell index – number of cell with minimum voltage;
38 38  * Maximum cell voltage, V;
39 -* # of Logic with maximum cell voltage – number of Logic with maximum voltage;
40 -* # of cell with maximum voltage – number of cell with maximum voltage;
42 +* Max. cell volt.: Logic index – number of Logic with maximum voltage;
43 +* Max. cell volt.: cell index – number of cell with maximum voltage;
41 41  * Minimum cell SOC, %;
42 -* # of Logic with minimum cell SOC – number of Logic with minimum SOC;
43 -* # of cell with minimum SOC – number of cell with minimum SOC;
45 +* Min. cell SOC: Logic index – number of Logic with minimum SOC;
46 +* Min. cell SOC: cell index – number of cell with minimum SOC;
44 44  * Maximum cell SOC, %;
45 -* # of Logic with maximum cell SOC – number of Logic with maximum SOC;
46 -* # of cell with maximum SOC – number of cell with maximum SOC;
48 +* Max. cell SOC: Logic index – number of Logic with maximum SOC;
49 +* Max. cell SOC: cell index – number of cell with maximum SOC;
47 47  * Number of balancing cells;
48 48  * State:
49 49  ** Discharging ON;
... ... @@ -54,7 +54,7 @@
54 54  ** Relaxed (after charging) – battery is in a state of relaxation after charging;
55 55  * Duration – duration of the battery in the "State" state, s;
56 56  * SOC – state of charge of the battery, %;
57 -* DOD – depth of discharge of the battery, %;
60 +* DOD – depth of discharge of the battery, A×h;
58 58  * SOH – state of health of the battery, %;
59 59  * Balancing efficiency – balancing efficiency of the battery, %;
60 60  * Effective capacity, А×h;
... ... @@ -69,98 +69,11 @@
69 69  * Work charge- - amount of charge transmitted to the load (negative direction) since device startup, Ah;
70 70  * Work energy+ - amount of energy received from charger (positive direction) since device startup, Wh;
71 71  * Work energy- - amount of energy transmitted to the load (negative direction) since device startup, Wh;
72 -* Total energy+ - total energy received by the battery modules from the charger and during recuperation, Wh;
75 +* Work energy regen - amount of regererated energy (positive direction) since device startup, Wh;
76 +* Total energy+ - total energy received by the battery modules from the charger, Wh;
73 73  * Total energy- - total energy spent by the battery modules on the load, Wh;
78 +* Total energy regen - total energy received by the battery modules during recuperation, Wh;
74 74  * Total balanced energy – total energy dissipated by the battery modules on balancing resistors, Wh;
75 -* Input singals:
76 -** Battery cover – a signal from the battery cover;
77 -** Charger connected – a signal indicating that charger is connected;
78 -** Power up/down request – a request to power down the device;
79 -** Inhibit charging – a command to open the charging contactor;
80 -** Inhibit discharging – a command to open the discharging contactor;
81 -** CH contactor feedback – a signal from charging contactor feedback loop;
82 -** DCH contactor feedback – a signal from discharging contactor feedback loop;
83 -** Insulation status – a signal from an insulation monitoring device;
84 -** Charge request – a request to close the charging contactor;
85 -** Precharge request – a request to close the precharging contactor;
86 -** Discharge request – a request to close the discharging contactor;
87 -** PCH contactor feedback – a signal from precharging contactor feedback loop;
88 -** CH/DCH contactor feedback – a signal from charging/discharging contactor feedback loop;
89 -** Main contactor feedback – a signal from main contactor feedback loop;
90 -** Interlock – a signal from interlock loop;
91 -** Fuse 1, Fuse 2, Fuse 3 – signals from fuses;
92 -** Circuit breaker status – status of protection disconnector;
93 -** Balancing request – a request to balance the cells;
94 -** Close Main contactor – a request to close the main contactor.
95 -* Internal signals – device internal signals:
96 -** Low SOC – a signal indicating the discharged battery;
97 -** High charging current;
98 -** Charging – state of the charging contactor;
99 -** Allow charging signal – signal allowing the operation of the charger;
100 -** Charging current present – charging current is detected;
101 -** Discharging – state of the discharging contactor;
102 -** Discharging current present – discharging current is detected;
103 -** Voltage is too high for charging;
104 -** Heater – signal to turn on heater;
105 -** Cooler – signal to turn on cooler;
106 -** Shutdown request (HYG/Spirit) – request to open the discharging contactor received from the HYG forklift;
107 -** Init – initialization of the device (calibration of the current sensor and searching BMS Logic devices);
108 -** Precharging – state of the precharging contactor;
109 -** Shutdown request (Combilift) – request to open the discharging contactor received from the Combilift forklift;
110 -** Cell analysis – operation of the algorithm for determining the discharge characteristics;
111 -** Balancing 1 – balancing the first series of cells;
112 -** Balancing 2 – balancing the second series of cells;
113 -** Discharging (AUX) – state of the discharging (AUX) contactor (powering of external equipment is on);
114 -** Power down ACK – signal to acknowledge powering down the battery system;
115 -** Crown EWS – signal sent to the Crown truck before opening the discharging contactor;
116 -** Main contactor – state of the main contactor;
117 -** Service reset;
118 -** Charging/Discharging – state of the charging/discharging contactor;
119 -** Ready to charge – the battery is ready to charge;
120 -** Ready to discharge – the battery is ready to discharge;
121 -** Power up – system power status;
122 -* Errors 1 – errors of the battery 1:
123 -** Overcurrent;
124 -** Undervoltage;
125 -** Overvoltage;
126 -** Low temperature (DCH) – temperature is too low for discharging;
127 -** High temperature (DCH) – temperature is too high for discharging;
128 -** Battery cover error – battery cover is open;
129 -** High humidity – humidity of the battery is increased;
130 -** Water – there is water in the battery enclosure;
131 -** High Logic temperature – at least one of the Logic devices is overheated;
132 -** Logic offline – at least one of the Logic devices is offline;
133 -** Critical error;
134 -** Crown error – connection with a Crown forklift is lost;
135 -** Cell count error – number of cells does not match the specified value;
136 -** HYG offline – connection with a HYG forklift is lost;
137 -** Combilift offline – connection with a Combilift forklift is lost;
138 -** Short circuit;
139 -** High contactor temperature;
140 -** ADC error – current cannot be measured;
141 -** Current sensor error – error in the current sensor circuit;
142 -** CH contactor cycles error – switching frequency of the charging contactor is too high;
143 -** DCH contactor cycles error – switching frequency of the discharging contactor is too high;
144 -** Shunt offline – connection with the shunt current sensor is lost;
145 -** Shunt error – internal error of the shunt current sensor;
146 -** WDT reset – watchdog timer reset the device;
147 -** No temperature sensors – the device has no temperature sensors connected;
148 -** Temperature sensor is shorted – some temperature sensors are shorted;
149 -** Spirit offline – connection with a Spirit forklift is lost;
150 -* Errors 2 – errors of the battery 2:
151 -** Low temperature (CH) – temperature is too low for charging;
152 -** High temperature (CH) – temperature is too high for charging;
153 -** Unallowable charging – charging the battery through the discharging contactor;
154 -** Stuck contactor;
155 -** CH contactor feedback error – the control signals for the charging contactor and the contactor feedback differ;
156 -** DCH contactor feedback error – the control signals for the discharging contactor and the contactor feedback differ;
157 -** Insulation fault;
158 -** PCH contactor feedback error – the control signals for the precharging contactor and the contactor feedback differ;
159 -** CH/DCH contactor feedback error – the control signals for the charging/discharging contactor and the contactor feedback differ;
160 -** Main contactor feedback error – the control signals for the main contactor and the contactor feedback differ;
161 -** General error;
162 -** High voltage fault – failure of high voltage measuring circuits;
163 -** Power switch error – short circuit in contactor coil control circuit or power switch overheating;
164 -** HVIL error – breakage of high-voltage interlock current loop;
165 -** Precharge error – capacitive load pre-charge process did not end during the estimated time;
166 -** Power fault – external devices power supply error: current sensors, HVIL, BMS Logic or CAN2 (int) bus powered devices.
80 +* Input signals – a bitfield including input signals (see [[Input signals>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInputsignals"]]);
81 +* Internal signals – a bitfield including device internal signals (see [[Internal signals>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInternalsignals"]]);
82 +* Errors 1, 2 – errors of the battery (see [[Errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HErrors"]]).
1735228916836-719.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +116.6 KB
Content
1750331354204-418.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +92.3 KB
Content
1750331506968-446.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +92.3 KB
Content