... ... @@ -1,1 +1,1 @@ 1 - drafts.BMS Main 3.4\. Monitoring.WebHome1 +Battery management systems.BMS Main 3.4\. Monitoring.WebHome - Content
-
... ... @@ -6,7 +6,7 @@ 6 6 7 7 Battery parameters are summarized in the "Battery" section: 8 8 9 -[[image:173 3403002027-572.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="507" width="800"]]9 +[[image:1735228916836-719.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="370" width="800"]] 10 10 11 11 In this section: 12 12 ... ... @@ -27,13 +27,13 @@ 27 27 * Number of cells – number of connected cells; 28 28 * Average cell temperature, °C; 29 29 * Minimum cell temperature, °C; 30 -* # of Logic with minimumcell temperature– number of Logic with minimum cell temperature;31 -* #ofcellwith minimum temperature – number of cell with minimum temperature;30 +* Min. cell temp.: Logic index – number of Logic with minimum cell temperature; 31 +* Min. cell temp.: cell index – number of cell with minimum temperature; 32 32 * Maximum cell temperature, °C; 33 -* # of Logic with maximumcell temperature– number of Logic with maximum cell temperature;34 -* #ofcellwith maximum temperature – number of cell with maximum temperature;33 +* Max. cell temp.: Logic index – number of Logic with maximum cell temperature; 34 +* Max. cell temp.: cell index – number of cell with maximum temperature; 35 35 * Minimum cell voltage, V; 36 -* #ofLogicwith minimum cellvoltage– number of Logic with minimum voltage;36 +* Max. cell temp.: Logic index – number of Logic with minimum voltage; 37 37 * # of cell with minimum voltage – number of cell with minimum voltage; 38 38 * Maximum cell voltage, V; 39 39 * # of Logic with maximum cell voltage – number of Logic with maximum voltage; ... ... @@ -72,6 +72,26 @@ 72 72 * Total energy+ - total energy received by the battery modules from the charger and during recuperation, Wh; 73 73 * Total energy- - total energy spent by the battery modules on the load, Wh; 74 74 * Total balanced energy – total energy dissipated by the battery modules on balancing resistors, Wh; 75 +* Input singals: 76 +** Battery cover – a signal from the battery cover; 77 +** Charger connected – a signal indicating that charger is connected; 78 +** Power up/down request – a request to power down the device; 79 +** Inhibit charging – a command to open the charging contactor; 80 +** Inhibit discharging – a command to open the discharging contactor; 81 +** CH contactor feedback – a signal from charging contactor feedback loop; 82 +** DCH contactor feedback – a signal from discharging contactor feedback loop; 83 +** Insulation status – a signal from an insulation monitoring device; 84 +** Charge request – a request to close the charging contactor; 85 +** Precharge request – a request to close the precharging contactor; 86 +** Discharge request – a request to close the discharging contactor; 87 +** PCH contactor feedback – a signal from precharging contactor feedback loop; 88 +** CH/DCH contactor feedback – a signal from charging/discharging contactor feedback loop; 89 +** Main contactor feedback – a signal from main contactor feedback loop; 90 +** Interlock – a signal from interlock loop; 91 +** Fuse 1, Fuse 2, Fuse 3 – signals from fuses; 92 +** Circuit breaker status – status of protection disconnector; 93 +** Balancing request – a request to balance the cells; 94 +** Close Main contactor – a request to close the main contactor. 75 75 * Internal signals – device internal signals: 76 76 ** Low SOC – a signal indicating the discharged battery; 77 77 ** High charging current;
- 1735228916836-719.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +116.6 KB - Content