Changes for page 4.2 Battery
Last modified by Admin on 2025/06/19 11:13
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Content
-
... ... @@ -6,12 +6,11 @@ 6 6 7 7 Battery parameters are summarized in the "Battery" section: 8 8 9 -[[image:17 50331506968-446.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="562" width="800"]]9 +[[image:1735228916836-719.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="370" width="800"]] 10 10 11 11 In this section: 12 12 13 -* Voltage (sum of cell voltages) – voltage of the battery, defined as sum of all cell voltages, V; 14 -* Voltage – voltage of the battery, measured before contactors, V; 13 +* Voltage – voltage of the battery, V; 15 15 * Current – current of the battery, A; 16 16 * Internal resistance – internal resistance of the battery, Ohm; 17 17 * Main voltage – supply voltage on the BMS, V; ... ... @@ -21,7 +21,6 @@ 21 21 * Temperature 1, 2 – temperature measured by the external temperature sensors, °C; 22 22 * Number of Logic devices – number of connected Logic devices; 23 23 * Logic command rate – number of commands transmitted to Logic devices, com/s; 24 -* Logic retry attempts – amount of BMS Logic retry attempts; 25 25 * Minimum Logic temperature – minimum temperature among Logic devices, °C; 26 26 * Min. Logic temp.: Logic index – number of Logic with minimum temperature; 27 27 * Maximum Logic temperature – minimum temperature among Logic devices, °C; ... ... @@ -34,7 +34,6 @@ 34 34 * Maximum cell temperature, °C; 35 35 * Max. cell temp.: Logic index – number of Logic with maximum cell temperature; 36 36 * Max. cell temp.: cell index – number of cell with maximum temperature; 37 -* Average cell voltage, V; 38 38 * Minimum cell voltage, V; 39 39 * Min. cell volt.: Logic index – number of Logic with minimum voltage; 40 40 * Min. cell volt.: cell index – number of cell with minimum voltage; ... ... @@ -57,7 +57,7 @@ 57 57 ** Relaxed (after charging) – battery is in a state of relaxation after charging; 58 58 * Duration – duration of the battery in the "State" state, s; 59 59 * SOC – state of charge of the battery, %; 60 -* DOD – depth of discharge of the battery, A×h;57 +* DOD – depth of discharge of the battery, %; 61 61 * SOH – state of health of the battery, %; 62 62 * Balancing efficiency – balancing efficiency of the battery, %; 63 63 * Effective capacity, А×h; ... ... @@ -78,5 +78,51 @@ 78 78 * Total energy regen - total energy received by the battery modules during recuperation, Wh; 79 79 * Total balanced energy – total energy dissipated by the battery modules on balancing resistors, Wh; 80 80 * Input signals – a bitfield including input signals (see [[Input signals>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInputsignals"]]); 81 -* Internal signals – a bitfield including device internal signals (see [[Internal signals>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInternalsignals"]]); 82 -* Errors 1, 2 – errors of the battery (see [[Errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HErrors"]]). 78 +* Internal signals – device internal signals: 79 +* Errors 1 – errors of the battery 1: 80 +** Overcurrent; 81 +** Undervoltage; 82 +** Overvoltage; 83 +** Low temperature (DCH) – temperature is too low for discharging; 84 +** High temperature (DCH) – temperature is too high for discharging; 85 +** Battery cover error – battery cover is open; 86 +** High humidity – humidity of the battery is increased; 87 +** Water – there is water in the battery enclosure; 88 +** High Logic temperature – at least one of the Logic devices is overheated; 89 +** Logic offline – at least one of the Logic devices is offline; 90 +** Critical error; 91 +** Crown error – connection with a Crown forklift is lost; 92 +** Cell count error – number of cells does not match the specified value; 93 +** HYG offline – connection with a HYG forklift is lost; 94 +** Need acknowledge – there is an unacknowledged error in Error journal; 95 +** Combilift offline – connection with a Combilift forklift is lost; 96 +** Short circuit; 97 +** High contactor temperature; 98 +** ADC error – current cannot be measured; 99 +** Current sensor error – error in the current sensor circuit; 100 +** CH contactor cycles error – switching frequency of the charging contactor is too high; 101 +** DCH contactor cycles error – switching frequency of the discharging contactor is too high; 102 +** Shunt offline – connection with the shunt current sensor is lost; 103 +** Shunt error – internal error of the shunt current sensor; 104 +** WDT reset – watchdog timer reset the device; 105 +** No temperature sensors – the device has no temperature sensors connected; 106 +** Temperature sensor is shorted – some temperature sensors are shorted; 107 +** Spirit offline – connection with a Spirit forklift is lost; 108 +* Errors 2 – errors of the battery 2: 109 +** Low temperature (CH) – temperature is too low for charging; 110 +** High temperature (CH) – temperature is too high for charging; 111 +** Unallowable charging – charging the battery through the discharging contactor; 112 +** Stuck contactor; 113 +** CH contactor feedback error – the control signals for the charging contactor and the contactor feedback differ; 114 +** DCH contactor feedback error – the control signals for the discharging contactor and the contactor feedback differ; 115 +** Insulation fault; 116 +** PCH contactor feedback error – the control signals for the precharging contactor and the contactor feedback differ; 117 +** CH/DCH contactor feedback error – the control signals for the charging/discharging contactor and the contactor feedback differ; 118 +** Main contactor feedback error – the control signals for the main contactor and the contactor feedback differ; 119 +** General error; 120 +** High voltage fault – failure of high voltage measuring circuits; 121 +** Power switch error – short circuit in contactor coil control circuit or power switch overheating; 122 +** HVIL error – breakage of high-voltage interlock current loop; 123 +** Precharge error – capacitive load pre-charge process did not end during the estimated time; 124 +** Power fault – external devices power supply error: current sensors, HVIL, BMS Logic or CAN2 (int) bus powered devices; 125 +** Current limit error – charging or discharging current is more than limit calculated by Charge map or Discharge map.
- 1750331354204-418.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -92.3 KB - Content
- 1750331506968-446.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -92.3 KB - Content