Changes for page 4.2 Battery
Last modified by Admin on 2025/06/19 11:13
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -6,12 +6,11 @@ 6 6 7 7 Battery parameters are summarized in the "Battery" section: 8 8 9 -[[image:17 50331506968-446.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="562" width="800"]]9 +[[image:1735228916836-719.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="370" width="800"]] 10 10 11 11 In this section: 12 12 13 -* Voltage (sum of cell voltages) – voltage of the battery, defined as sum of all cell voltages, V; 14 -* Voltage – voltage of the battery, measured before contactors, V; 13 +* Voltage – voltage of the battery, V; 15 15 * Current – current of the battery, A; 16 16 * Internal resistance – internal resistance of the battery, Ohm; 17 17 * Main voltage – supply voltage on the BMS, V; ... ... @@ -21,7 +21,6 @@ 21 21 * Temperature 1, 2 – temperature measured by the external temperature sensors, °C; 22 22 * Number of Logic devices – number of connected Logic devices; 23 23 * Logic command rate – number of commands transmitted to Logic devices, com/s; 24 -* Logic retry attempts – amount of BMS Logic retry attempts; 25 25 * Minimum Logic temperature – minimum temperature among Logic devices, °C; 26 26 * Min. Logic temp.: Logic index – number of Logic with minimum temperature; 27 27 * Maximum Logic temperature – minimum temperature among Logic devices, °C;