States of the KEYRUN and CHARGE_ON signals are available in the "Signals" section.

States of the device's discrete inputs are available in the "Signals → Input discrete signal" section:

1739295295106-897.png

In this section:

  • Input #1 - Input #8 – physical states of the inputs 1-4 respectively.

The states of the discrete output signals are available in the "Signals → Output discrete signals" section:

1739295317402-295.png

In this section:

  • Output #1 - Output #4 – physical states of the outputs 1-4 respectively.

The states of the power switches are available in the "Signals → Power switches" section:

1739295355873-803.png

In this section:

  • Power switch #1 - Power switch #6 – physical states of the power switches 1-6 respectively.

Current sensor

The states of the current sensors are available in the "Signals → Current sensor" section:

1733402780557-330.png

In this section:

  • Sensor 1, 2, 3: IN1 – output signal from the current sensor, V;
  • Sensor 1, 2, 3: REF_IN2 – signal in the reference line, V;
  • Sensor 1, 2, 3: Value – calculated value of the current, A;
  • Sensor 1, 2, 3: Low range – calculated value of the lower range current, A.

Shunt sensor

The state of the shunt sensor is available in the "Signals → Shunt sensor" section:

1733402780565-376.png

In this section:

  • Online – a flag showing that the communication with the BMS Current Sensor is established;
  • Errors – a list of internal errors of the shunt sensor;
  • Current – an instantaneous value of current measured by the BMS Current Sensor, A (measuring frequency is 50 Hz);
  • Current (mean) – a mean value of current measured by the BMS Current Sensor, A (the value is calculated as an average of 100 consistent measurements);
  • Temperature – a temperature of the shunt sensor, °C.

HVIL

The state of the HVIL is available in the "Signals → HVIL" section:

1733402780566-996.png

In this section:

  • Current (power off) – high voltage interlock loop current at power off, A;
  • Current (power on) – high voltage interlock loop current at power on, A.