Wiki source code of 4.1 Signals
Show last authors
author | version | line-number | content |
---|---|---|---|
1 | (% data-numbered-headings-start="4" style="--numbered-headings-start: 3;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) | ||
2 | = Monitoring = | ||
3 | |||
4 | (% data-numbered-headings-start="1" style="--numbered-headings-start: 0;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) | ||
5 | == Signals == | ||
6 | |||
7 | States of the KEYRUN and CHARGE_ON signals are available in the "Signals" section. | ||
8 | |||
9 | States of the device's discrete inputs are available in the "Signals → Input discrete signal" section: | ||
10 | |||
11 | [[image:1739295295106-897.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="200" width="800"]] | ||
12 | |||
13 | In this section: | ||
14 | |||
15 | * Input #1 - Input #8 – physical states of the inputs 1-4 respectively. | ||
16 | |||
17 | The states of the discrete output signals are available in the "Signals → Output discrete signals" section: | ||
18 | |||
19 | [[image:1739295317402-295.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="159" width="800"]] | ||
20 | |||
21 | In this section: | ||
22 | |||
23 | * Output #1 - Output #4 – physical states of the outputs 1-4 respectively. | ||
24 | |||
25 | The states of the power switches are available in the "Signals → Power switches" section: | ||
26 | |||
27 | |||
28 | In this section: | ||
29 | |||
30 | * Power switch #1 - Power switch #6 – physical states of the power switches 1-6 respectively. | ||
31 | |||
32 | === Current sensor === | ||
33 | |||
34 | The states of the current sensors are available in the "Signals → Current sensor" section: | ||
35 | |||
36 | [[image:1733402780557-330.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="217" width="800"]] | ||
37 | |||
38 | In this section: | ||
39 | |||
40 | * Sensor 1, 2, 3: IN1 – output signal from the current sensor, V; | ||
41 | * Sensor 1, 2, 3: REF_IN2 – signal in the reference line, V; | ||
42 | * Sensor 1, 2, 3: Value – calculated value of the current, A; | ||
43 | * Sensor 1, 2, 3: Low range – calculated value of the lower range current, A. | ||
44 | |||
45 | === Shunt sensor === | ||
46 | |||
47 | The state of the shunt sensor is available in the "Signals → Shunt sensor" section: | ||
48 | |||
49 | [[image:1733402780565-376.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="120" width="800"]] | ||
50 | |||
51 | In this section: | ||
52 | |||
53 | * Online – a flag showing that the communication with the BMS Current Sensor is established; | ||
54 | * Errors – a list of internal errors of the shunt sensor; | ||
55 | * Current – an instantaneous value of current measured by the BMS Current Sensor, A (measuring frequency is 50 Hz); | ||
56 | * Current (mean) – a mean value of current measured by the BMS Current Sensor, A (the value is calculated as an average of 100 consistent measurements); | ||
57 | * Temperature – a temperature of the shunt sensor, °C. | ||
58 | |||
59 | === HVIL === | ||
60 | |||
61 | The state of the HVIL is available in the "Signals → HVIL" section: | ||
62 | |||
63 | [[image:1733402780566-996.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="95" width="800"]] | ||
64 | |||
65 | In this section: | ||
66 | |||
67 | * Current (power off) – high voltage interlock loop current at power off, A; | ||
68 | * Current (power on) – high voltage interlock loop current at power on, A. |