Wiki source code of 4.1 Signals
Show last authors
author | version | line-number | content |
---|---|---|---|
1 | (% data-numbered-headings-start="4" style="--numbered-headings-start: 3;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) | ||
2 | = Monitoring = | ||
3 | |||
4 | (% data-numbered-headings-start="1" style="--numbered-headings-start: 0;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) | ||
5 | == Signals == | ||
6 | |||
7 | States of the device's discrete inputs are available in the "Signals → Input discrete signal" section: | ||
8 | |||
9 | [[image:1733402780551-891.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="448" width="800"]] | ||
10 | |||
11 | In this section: | ||
12 | |||
13 | * Battery cover – a signal from the battery cover; | ||
14 | * Charger connected – a signal indicating that charger is connected; | ||
15 | * Power up/down request – a request to power down the device; | ||
16 | * Inhibit charging – a command to open the charging contactor; | ||
17 | * Inhibit discharging – a command to open the discharging contactor; | ||
18 | * CH contactor feedback – a signal from charging contactor feedback loop; | ||
19 | * DCH contactor feedback – a signal from discharging contactor feedback loop; | ||
20 | * Insulation status – a signal from an insulation monitoring device; | ||
21 | * Charge request – a request to close the charging contactor; | ||
22 | * Precharge request – a request to close the precharging contactor; | ||
23 | * Discharge request – a request to close the discharging contactor; | ||
24 | * PCH contactor feedback – a signal from precharging contactor feedback loop; | ||
25 | * CH/DCH contactor feedback – a signal from charging/discharging contactor feedback loop; | ||
26 | * Main contactor feedback – a signal from main contactor feedback loop; | ||
27 | * Interlock – a signal from interlock loop; | ||
28 | * Fuse 1, Fuse 2, Fuse 3 – signals from fuses; | ||
29 | * Circuit breaker status – status of protection disconnector; | ||
30 | * Balancing request – a request to balance the cells; | ||
31 | * Close Main contactor – a request to close the main contactor. | ||
32 | |||
33 | The states of the discrete output signals are available in the "Signals → Output discrete signals" section: | ||
34 | |||
35 | [[image:1733402780555-886.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="146" width="800"]] | ||
36 | |||
37 | In this section: | ||
38 | |||
39 | * Output #1 - Output #4 – states of the outputs 1-4 respectively. | ||
40 | |||
41 | The states of the power switches are available in the "Signals → Power switches" section: | ||
42 | |||
43 | [[image:1733402780556-463.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="187" width="800"]] | ||
44 | |||
45 | In this section: | ||
46 | |||
47 | * Power switch #1 - Power switch #6 – states of the Power switches 1-6 respectively. | ||
48 | |||
49 | === Current sensor === | ||
50 | |||
51 | The states of the current sensors are available in the "Signals → Current sensor" section: | ||
52 | |||
53 | [[image:1733402780557-330.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="217" width="800"]] | ||
54 | |||
55 | In this section: | ||
56 | |||
57 | * Sensor 1, 2, 3: IN1 – output signal from the current sensor, V; | ||
58 | * Sensor 1, 2, 3: REF_IN2 – signal in the reference line, V; | ||
59 | * Sensor 1, 2, 3: Value – calculated value of the current, A; | ||
60 | * Sensor 1, 2, 3: Low range – calculated value of the lower range current, A. | ||
61 | |||
62 | === Shunt sensor === | ||
63 | |||
64 | The state of the shunt sensor is available in the "Signals → Shunt sensor" section: | ||
65 | |||
66 | [[image:1733402780565-376.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="120" width="800"]] | ||
67 | |||
68 | In this section: | ||
69 | |||
70 | * Online – a flag showing that the communication with the BMS Current Sensor is established; | ||
71 | * Errors – a list of internal errors of the shunt sensor; | ||
72 | * Current – an instantaneous value of current measured by the BMS Current Sensor, A (measuring frequency is 50 Hz); | ||
73 | * Current (mean) – a mean value of current measured by the BMS Current Sensor, A (the value is calculated as an average of 100 consistent measurements); | ||
74 | * Temperature – a temperature of the shunt sensor, °C. | ||
75 | |||
76 | === HVIL === | ||
77 | |||
78 | The state of the HVIL is available in the "Signals → HVIL" section: | ||
79 | |||
80 | [[image:1733402780566-996.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="95" width="800"]] | ||
81 | |||
82 | In this section: | ||
83 | |||
84 | * Current (power off) – high voltage interlock loop current at power off, A; | ||