Changes for page 4.1 Signals
Last modified by Admin on 2025/02/11 17:36
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 - Battery managementystems.BMS Main1 +drafts.bms-main-3.4\. Monitoring.WebHome - Content
-
... ... @@ -4,8 +4,6 @@ 4 4 (% data-numbered-headings-start="1" style="--numbered-headings-start: 0;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 5 5 == Signals == 6 6 7 -States of the KEYRUN and CHARGE_ON signals are available in the "Signals → Input discrete signal" section: 8 - 9 9 States of the device's discrete inputs are available in the "Signals → Input discrete signal" section: 10 10 11 11 [[image:1733402780551-891.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="448" width="800"]] ... ... @@ -12,7 +12,25 @@ 12 12 13 13 In this section: 14 14 15 -* Input #1 - Input #8 – physical states of the inputs 1-4 respectively. 13 +* Battery cover – a signal from the battery cover; 14 +* Charger connected – a signal indicating that charger is connected; 15 +* Power up/down request – a request to power down the device; 16 +* Inhibit charging – a command to open the charging contactor; 17 +* Inhibit discharging – a command to open the discharging contactor; 18 +* CH contactor feedback – a signal from charging contactor feedback loop; 19 +* DCH contactor feedback – a signal from discharging contactor feedback loop; 20 +* Insulation status – a signal from an insulation monitoring device; 21 +* Charge request – a request to close the charging contactor; 22 +* Precharge request – a request to close the precharging contactor; 23 +* Discharge request – a request to close the discharging contactor; 24 +* PCH contactor feedback – a signal from precharging contactor feedback loop; 25 +* CH/DCH contactor feedback – a signal from charging/discharging contactor feedback loop; 26 +* Main contactor feedback – a signal from main contactor feedback loop; 27 +* Interlock – a signal from interlock loop; 28 +* Fuse 1, Fuse 2, Fuse 3 – signals from fuses; 29 +* Circuit breaker status – status of protection disconnector; 30 +* Balancing request – a request to balance the cells; 31 +* Close Main contactor – a request to close the main contactor. 16 16 17 17 The states of the discrete output signals are available in the "Signals → Output discrete signals" section: 18 18 ... ... @@ -20,7 +20,7 @@ 20 20 21 21 In this section: 22 22 23 -* Output #1 - Output #4 – physical states of the outputs 1-4 respectively.39 +* Output #1 - Output #4 – states of the outputs 1-4 respectively. 24 24 25 25 The states of the power switches are available in the "Signals → Power switches" section: 26 26 ... ... @@ -28,7 +28,7 @@ 28 28 29 29 In this section: 30 30 31 -* Power switch #1 - Power switch #6 – physical states of thepower switches 1-6 respectively.47 +* Power switch #1 - Power switch #6 – states of the Power switches 1-6 respectively. 32 32 33 33 === Current sensor === 34 34